calculate_effective_capacitance

Read-onlyIdempotent

Effective capacitance of a Class II MLCC at real operating conditions — the marked value is not the value in circuit. Multiplies the four loss mechanisms that compound: DC bias (the dominant one, typically 35-65% loss at rated voltage and…

Instructions

Effective capacitance of a Class II MLCC at real operating conditions — the marked value is not the value in circuit. Multiplies the four loss mechanisms that compound: DC bias (the dominant one, typically 35-65% loss at rated voltage and worse in small cases), AC signal level, temperature coefficient, and logarithmic dielectric ageing, then applies the part tolerance. Returns the full factor stack so you can see which mechanism hurt most. Class I (C0G/NP0) parts correctly short-circuit to tolerance-only. Pass measured_retention_at_bias from a datasheet curve (Murata SimSurfing, TDK SEAT) to replace the band estimate and get confidence='measured'.

Input Schema

TableJSON Schema
NameRequiredDescriptionDefault
rated_vYesThe part's rated DC voltage.
ac_levelNoSignal magnitude class: small_signal (<50 mVrms), moderate (50-500 mVrms), or large (>500 mVrms). Small signals see less capacitance.small_signal
ambient_cNoOperating ambient temperature in °C.
applied_vYesDC bias actually across the part in this circuit, in volts.
case_sizeNoEIA case code: 0402, 0603, 0805, 1206 or 1210. Larger cases retain more capacitance under bias.0805
dielectricNoEIA Class II dielectric: X5R, X7R, X8R, Y5V, Z5U, or Class I C0G/NP0.X5R
tolerance_pctNoThe part's capacitance tolerance in percent (e.g. 10 for ±10%). Applied at the pessimistic end.
hours_in_serviceNoExpected service life in hours, used for the log-time ageing term.
marked_capacitance_ufYesThe capacitance printed on the reel, in µF.
measured_retention_at_biasNoRetention fraction (0-1] read from the real datasheet DC-bias curve at applied_v. Replaces the band estimate.

Output Schema

TableJSON Schema
NameRequiredDescriptionDefault
notesYesHuman-readable findings: which term dominates, what to change, and any caveat.
sourceYesThe measurements and standards the model is calibrated against.
rated_vYesThe part's rated DC voltage.
loss_pctYesPercentage of the marked value that is lost.
ambient_cYesOperating ambient used.
applied_vYesDC bias across the part that was analysed.
case_sizeYesEIA case code analysed.
confidenceYesHow trustworthy the number is: 'measured' from a datasheet curve, 'band' from a published retention range, 'physical' for Class I parts where the loss is zero by physics.
dielectricYesEIA dielectric class analysed.
ageing_factorYesRetention after the service life, log-time law.
dc_bias_factorYesRetention from DC bias alone — usually the dominant term.
ac_level_factorYesRetention from AC signal magnitude (ferroelectric hysteresis).
hours_in_serviceYesService life used for the ageing term.
tolerance_factorYesRetention at the pessimistic end of the part tolerance.
retention_fractionYeseffective / marked, after every loss mechanism.
temperature_factorYesRetention at the operating temperature, worst-case end of the TCC band.
marked_capacitance_ufYesThe value printed on the reel.
effective_capacitance_ufYesThe capacitance the circuit actually gets.