omni_wire_gauge_drop
Calculate voltage drop, percentage loss, and voltage at load for single-phase copper circuits, then check NEC 3% compliance and recommended AWG conductor sizing.
Instructions
Voltage Drop & Wire Gauge (AWG) Calculator. Calculate electrical voltage drop, percentage loss, and proper American Wire Gauge (AWG) conductor sizing for single-phase copper circuits. Discipline: CONSTRUCTION. Governing mathematical model / formula: Voltage Drop (VD) = [2 × K × I × Length (ft)] / Circular Mils (CM).
USAGE GUIDELINES:
WHEN TO USE: Invoke for deterministic calculation of voltage_drop_volts (Total Voltage Drop), percentage_drop (Percentage Voltage Drop), voltage_at_load (Voltage Delivered to Load), nec_compliance (NEC Rec. (<3% Branch Limit)) using circuit_voltage (Circuit Voltage in volts), load_amperes (Continuous Load Amperage in amps), one_way_distance (One-Way Conductor Length in ft), wire_gauge (Wire Gauge (12 for 12AWG, 10 for 10AWG) in AWG). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.
WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.
DISAMBIGUATION & BOUNDARIES:
Use this dedicated specialist tool for 'Voltage Drop & Wire Gauge (AWG) Calculator' rather than generic dispatchers like omni_universal_query.
For multi-calculation chained jobs, use 'omni_batch_calculate'.
To inspect schema fields, see 'omni_describe_solver'.
BEHAVIOR & SAFETY:
Pure deterministic computation with machine floating-point precision.
Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.
Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.
RETURNS:
Structured JSON object containing:
status (string): "success" on valid execution or "error" if validation fails
calculator (string): "wire-gauge-drop"
category (string): "construction"
name (string): "Voltage Drop & Wire Gauge (AWG) Calculator"
formula (string): Governing mathematical formula string
inputs (object): Echoed input parameter dictionary with applied defaults
metrics (object): Dictionary of computed outputs:
metrics.voltage_drop_volts (Total Voltage Drop): Formatted display string (e.g. '6.35 Volts')
metrics.percentage_drop (Percentage Voltage Drop): Formatted display string (e.g. '5.29%')
metrics.voltage_at_load (Voltage Delivered to Load): Formatted display string (e.g. '113.65 Volts')
metrics.nec_compliance (NEC Rec. (<3% Branch Limit)): Formatted display string (e.g. 'Fails 3% limit (Upsize to 10 AWG)')
execution_time_ms (number): Latency in milliseconds.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "omni_wire_gauge_drop"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| wire_gauge | No | Wire Gauge (12 for 12AWG, 10 for 10AWG) (AWG). 14 AWG (15A), 12 AWG (20A), 10 AWG (30A), 8 AWG (50A). Default: 12. Min: 0. Max: 14. | |
| load_amperes | No | Continuous Load Amperage (amps). 16A continuous on a 20A breaker (80% rule). Default: 16. Min: 1. Max: 200. | |
| circuit_voltage | No | Circuit Voltage (volts). 120V standard branch circuit, 240V for heavy equipment. Default: 120. Min: 12. Max: 480. | |
| one_way_distance | No | One-Way Conductor Length (ft). Distance from panel to load. Default: 100. Min: 10. Max: 1000. |