omni_retaining_wall
Calculate retaining wall blocks, capstones, drainage gravel, and perforated drain pipe from wall length, height, and block dimensions for accurate construction material estimates.
Instructions
Retaining Wall Block & Backfill Calculator. Calculate retaining wall blocks, capstones, gravel drainage backfill, and perforated drain tile pipe. Discipline: CONSTRUCTION. Governing mathematical model / formula: Blocks = [Wall Length (ft) × Wall Height (ft)] / Block Face Area (sq ft).
USAGE GUIDELINES:
WHEN TO USE: Invoke for deterministic calculation of blocks_needed (Total Retaining Blocks), cap_stones (Cap Stones (Linear Feet)), drainage_gravel (Drainage Gravel Backfill (12" deep)), drain_pipe (Perforated 4" Drain Pipe) using length (Wall Length in ft), height (Exposed Wall Height in ft), block_length (Block Face Length in in), block_height (Block Height in in). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.
WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.
SIBLING ROUTING: Use this dedicated specialist tool for 'Retaining Wall Block & Backfill Calculator' rather than generic dispatchers like omni_universal_query. For cross-discipline dynamic dispatch, see omni_universal_query.
BEHAVIOR & SAFETY:
Pure deterministic computation with machine floating-point precision.
Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.
Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.
RETURNS:
Structured JSON object containing:
status (string): "success" on valid execution or "error" if validation fails
calculator (string): "retaining-wall"
category (string): "construction"
name (string): "Retaining Wall Block & Backfill Calculator"
formula (string): Governing mathematical formula string
inputs (object): Echoed input parameter dictionary with applied defaults
metrics (object): Dictionary of computed outputs:
metrics.blocks_needed (Total Retaining Blocks): Formatted display string (e.g. '315 blocks')
metrics.cap_stones (Cap Stones (Linear Feet)): Formatted display string (e.g. '30 units (30 ft)')
metrics.drainage_gravel (Drainage Gravel Backfill (12" deep)): Formatted display string (e.g. '3.33 cu yd (4.66 tons)')
metrics.drain_pipe (Perforated 4" Drain Pipe): Formatted display string (e.g. '30 linear ft')
execution_time_ms (number): Latency in milliseconds.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "omni_retaining_wall"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| height | No | Exposed Wall Height (ft). Exposed height above grade (add 1 buried course). Default: 3. Min: 1. Max: 10. | |
| length | No | Wall Length (ft). Total running length of the retaining wall. Default: 30. Min: 4. Max: 200. | |
| block_height | No | Block Height (in). Height of block in inches. Default: 4. Min: 3. Max: 8. | |
| block_length | No | Block Face Length (in). Length of block face in inches. Default: 12. Min: 8. Max: 18. |