Skip to main content
Glama
omnioperand-mcp

omnioperand-mcp

omni_asce7_wind_load_pressure

Calculate ASCE 7 design wind velocity pressure (q_z) in PSF from basic wind speed, exposure category, and mean roof height, including K_z, roof cladding suction, and dynamic pressure.

Instructions

ASCE 7 Wind Load Velocity Pressure on Building Envelopes Calculator. Calculate design wind velocity pressure (q_z in PSF) based on basic wind speed, surface roughness exposure category (B, C, D), and mean roof height (ASCE 7-16 / 7-22). Discipline: ENGINEERING. Governing mathematical model / formula: Velocity Pressure q_z = 0.00256 · K_z · K_zt · K_d · K_e · V².

USAGE GUIDELINES:

  • WHEN TO USE: Invoke for deterministic calculation of velocity_pressure_qz (Design Velocity Pressure (q_z)), height_exposure_factor_kz (Velocity Pressure Coefficient (K_z)), cladding_peak_suction_psf (Corner Roof Cladding Suction), dynamic_impact_head_psi (Dynamic Wind Pressure) using basic_wind_speed_mph (Basic Design Wind Speed (mph) in mph (3-sec gust)), mean_roof_height_ft (Mean Roof Height (Feet) in ft), exposure_category (Surface Exposure Category (1 = B Suburban, 2 = C Open Grass, 3 = D Coastal)), wind_directionality_kd (Wind Directionality Factor (K_d)). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.

  • WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.

DISAMBIGUATION & BOUNDARIES:

  • Use this dedicated specialist tool for 'ASCE 7 Wind Load Velocity Pressure on Building Envelopes Calculator' rather than generic dispatchers like omni_universal_query.

  • For multi-calculation chained jobs, use 'omni_batch_calculate'.

  • To inspect schema fields, see 'omni_describe_solver'.

BEHAVIOR & SAFETY:

  • Pure deterministic computation with machine floating-point precision.

  • Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.

  • Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.

RETURNS:

  • Structured JSON object containing:

    • status (string): "success" on valid execution or "error" if validation fails

    • calculator (string): "asce7-wind-load-pressure"

    • category (string): "engineering"

    • name (string): "ASCE 7 Wind Load Velocity Pressure on Building Envelopes Calculator"

    • formula (string): Governing mathematical formula string

    • inputs (object): Echoed input parameter dictionary with applied defaults

    • metrics (object): Dictionary of computed outputs:

      • metrics.velocity_pressure_qz (Design Velocity Pressure (q_z)): Formatted display string (e.g. '20.3 PSF')

      • metrics.height_exposure_factor_kz (Velocity Pressure Coefficient (K_z)): Formatted display string (e.g. '0.70 (Exposure B @ 30 ft)')

      • metrics.cladding_peak_suction_psf (Corner Roof Cladding Suction): Formatted display string (e.g. '-38.6 PSF (Zone 3 Uplift)')

      • metrics.dynamic_impact_head_psi (Dynamic Wind Pressure): Formatted display string (e.g. '0.14 PSI')

    • execution_time_ms (number): Latency in milliseconds.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "omni_asce7_wind_load_pressure"
  }
}

Input Schema

NameRequiredDescriptionDefault
exposure_categoryNoSurface Exposure Category (1 = B Suburban, 2 = C Open Grass, 3 = D Coastal). B: Urban/suburban wooded, C: Open terrain, D: Flat water/coastal. Default: 1. Min: 1. Max: 3.
mean_roof_height_ftNoMean Roof Height (Feet) (ft). Average height between eave and ridge. Default: 30. Min: 10. Max: 250.
basic_wind_speed_mphNoBasic Design Wind Speed (mph) (mph (3-sec gust)). ASCE 7-16 hazard wind speed map for project location. Default: 115. Min: 85. Max: 200.
wind_directionality_kdNoWind Directionality Factor (K_d). 0.85 for Main Wind-Force Resisting System (MWFRS) and Components. Default: 0.85. Min: 0.85. Max: 1.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Addedv0.1.2

TDQS

Score is being calculated.

Deploy Server

Other Tools