Skip to main content
Glama
omnioperand-mcp

omnioperand-mcp

omni_degree_days_energy_audit

Calculates weather-normalized annual heating and cooling energy loads from degree days, floor area, and insulation quality, returning therms, kWh, and heating-versus-cooling load split without arithmetic errors.

Instructions

Heating & Cooling Degree Days (HDD / CDD) Thermal Audit Calculator. Calculate weather-normalized annual building thermal load in therms and kWh using Heating Degree Days (HDD) and Cooling Degree Days (CDD). Discipline: ENERGY. Governing mathematical model / formula: HDD = Σ max(0, 65°F - T_mean) | Annual Heat BTU = UA_building × HDD × 24.

USAGE GUIDELINES:

  • WHEN TO USE: Invoke for deterministic calculation of annual_heating_therms (Estimated Annual Heating Energy), annual_cooling_kwh (Estimated Annual Cooling Energy), building_ua_factor (Building Overall Heat Loss Rate), climate_heating_pct (Heating vs Cooling Load Dominance) using annual_hdd (Annual Heating Degree Days (Base 65°F) in HDD), annual_cdd (Annual Cooling Degree Days (Base 65°F) in CDD), building_sqft (Conditioned Floor Area (sq ft) in sq ft), insulation_quality (Building Envelope Code (1 = Poor/Old, 2 = Standard, 3 = High Performance)). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.

  • WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.

DISAMBIGUATION & BOUNDARIES:

  • Use this dedicated specialist tool for 'Heating & Cooling Degree Days (HDD / CDD) Thermal Audit Calculator' rather than generic dispatchers like omni_universal_query.

  • For multi-calculation chained jobs, use 'omni_batch_calculate'.

  • To inspect schema fields, see 'omni_describe_solver'.

BEHAVIOR & SAFETY:

  • Pure deterministic computation with machine floating-point precision.

  • Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.

  • Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.

RETURNS:

  • Structured JSON object containing:

    • status (string): "success" on valid execution or "error" if validation fails

    • calculator (string): "degree-days-energy-audit"

    • category (string): "energy"

    • name (string): "Heating & Cooling Degree Days (HDD / CDD) Thermal Audit Calculator"

    • formula (string): Governing mathematical formula string

    • inputs (object): Echoed input parameter dictionary with applied defaults

    • metrics (object): Dictionary of computed outputs:

      • metrics.annual_heating_therms (Estimated Annual Heating Energy): Formatted display string (e.g. '756.0 Therms')

      • metrics.annual_cooling_kwh (Estimated Annual Cooling Energy): Formatted display string (e.g. '3,136 kWh')

      • metrics.building_ua_factor (Building Overall Heat Loss Rate): Formatted display string (e.g. '300 BTU/hr·°F')

      • metrics.climate_heating_pct (Heating vs Cooling Load Dominance): Formatted display string (e.g. '75% Heating / 25% Cooling')

    • execution_time_ms (number): Latency in milliseconds.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "omni_degree_days_energy_audit"
  }
}

Input Schema

NameRequiredDescriptionDefault
annual_cddNoAnnual Cooling Degree Days (Base 65°F) (CDD). Climatic cooling degree days for your zip code. Default: 1400. Min: 200. Max: 5000.
annual_hddNoAnnual Heating Degree Days (Base 65°F) (HDD). Climatic heating degree days for your zip code. Default: 4200. Min: 500. Max: 10000.
building_sqftNoConditioned Floor Area (sq ft) (sq ft). Total heated and cooled indoor square footage. Default: 2400. Min: 500. Max: 50000.
insulation_qualityNoBuilding Envelope Code (1 = Poor/Old, 2 = Standard, 3 = High Performance). 1: Pre-1980, 2: Modern IECC code, 3: Passivhaus / Net Zero. Default: 2. Min: 1. Max: 3.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Addedv0.1.2

TDQS

Score is being calculated.