Calculate running watts, surge (starting) watts, and recommended generator size for whole-home or portable backup power using appliance load inputs.

Instructions

Generator Sizing & Starting Watts Calculator. Calculate running watts and surge (starting) watts for whole-home and portable emergency backup generators. Discipline: CONSTRUCTION. Governing mathematical model / formula: Generator Size = Total Running Watts + Largest Motor Surge Watts.

USAGE GUIDELINES:

  • WHEN TO USE: Invoke for deterministic calculation of recommended_generator (Minimum Generator Rating), running_watts (Continuous Running Watts), peak_surge_watts (Peak Starting Surge Load), fuel_runtime (Est. 50% Load Fuel Burn) using refrigerator (Refrigerators & Freezers), sump_pump (Sump Pump (1/2 HP)), well_pump (Deep Well Pump (1 HP)), portable_heater (Baseboard / Space Heaters), general_lighting (Lighting & Electronics Allowance in watts). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.

  • WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.

  • SIBLING ROUTING: Use this dedicated specialist tool for 'Generator Sizing & Starting Watts Calculator' rather than generic dispatchers like omni_universal_query. For cross-discipline dynamic dispatch, see omni_universal_query.

BEHAVIOR & SAFETY:

  • Pure deterministic computation with machine floating-point precision.

  • Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.

  • Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.

RETURNS:

  • Structured JSON object containing:

    • status (string): "success" on valid execution or "error" if validation fails

    • calculator (string): "generator-sizing"

    • category (string): "construction"

    • name (string): "Generator Sizing & Starting Watts Calculator"

    • formula (string): Governing mathematical formula string

    • inputs (object): Echoed input parameter dictionary with applied defaults

    • metrics (object): Dictionary of computed outputs:

      • metrics.recommended_generator (Minimum Generator Rating): Formatted display string (e.g. '7,500 Watts')

      • metrics.running_watts (Continuous Running Watts): Formatted display string (e.g. '5,150 Watts')

      • metrics.peak_surge_watts (Peak Starting Surge Load): Formatted display string (e.g. '6,650 Watts')

      • metrics.fuel_runtime (Est. 50% Load Fuel Burn): Formatted display string (e.g. '~0.55 gal/hr gasoline')

    • execution_time_ms (number): Latency in milliseconds.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "omni_generator_sizing"
  }
}

Input Schema

NameRequiredDescriptionDefault
sump_pumpNoSump Pump (1/2 HP). 1,050 running watts, 2,150 starting surge watts. Default: 1. Min: 0. Max: 2.
well_pumpNoDeep Well Pump (1 HP). 2,000 running watts, 4,000 starting surge watts. Default: 0. Min: 0. Max: 1.
refrigeratorNoRefrigerators & Freezers. 700 running watts, 2,200 starting surge watts each. Default: 2. Min: 0. Max: 4.
portable_heaterNoBaseboard / Space Heaters. 1,500 running watts each (no surge). Default: 1. Min: 0. Max: 3.
general_lightingNoLighting & Electronics Allowance (watts). LED lights, TVs, Wi-Fi router, laptop chargers. Default: 1200. Min: 200. Max: 5000.