Skip to main content
Glama
omnioperand-mcp

omnioperand-mcp

omni_centrifuge_rcf_g_force

Convert RPM to relative centrifugal force (RCF/×g) or reverse using rotor radius to reproduce centrifugation protocols accurately.

Instructions

Centrifuge Relative Centrifugal Force (RCF / g-Force) & RPM Calculator. Convert between rotational speed (RPM) and Relative Centrifugal Force (RCF in ×g) using exact rotor radius geometry to reproduce centrifugation protocols. Discipline: BIOTECH. Governing mathematical model / formula: RCF (×g) = 1.118 × 10⁻⁵ · r_cm · (RPM)² | RPM = √[RCF / (1.118 × 10⁻⁵ · r_cm)].

USAGE GUIDELINES:

  • WHEN TO USE: Invoke for deterministic calculation of relative_centrifugal_force_rcf (Relative Centrifugal Force (RCF)), tangential_linear_velocity (Tube Tangential Velocity), protocol_centrifugation_tier (Centrifugation Application Tier), radius_variance_factor (Rotor Radius Metric) using centrifuge_rotor_speed_rpm (Rotational Speed (RPM) in RPM), rotor_radius_centimeters (Rotor Radius (r in cm) in cm). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.

  • WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.

DISAMBIGUATION & BOUNDARIES:

  • Use this dedicated specialist tool for 'Centrifuge Relative Centrifugal Force (RCF / g-Force) & RPM Calculator' rather than generic dispatchers like omni_universal_query.

  • For multi-calculation chained jobs, use 'omni_batch_calculate'.

  • To inspect schema fields, see 'omni_describe_solver'.

BEHAVIOR & SAFETY:

  • Pure deterministic computation with machine floating-point precision.

  • Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.

  • Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.

RETURNS:

  • Structured JSON object containing:

    • status (string): "success" on valid execution or "error" if validation fails

    • calculator (string): "centrifuge-rcf-g-force"

    • category (string): "biotech"

    • name (string): "Centrifuge Relative Centrifugal Force (RCF / g-Force) & RPM Calculator"

    • formula (string): Governing mathematical formula string

    • inputs (object): Echoed input parameter dictionary with applied defaults

    • metrics (object): Dictionary of computed outputs:

      • metrics.relative_centrifugal_force_rcf (Relative Centrifugal Force (RCF)): Formatted display string (e.g. '18,624 ×g')

      • metrics.tangential_linear_velocity (Tube Tangential Velocity): Formatted display string (e.g. '124.6 m/s (448.6 km/h)')

      • metrics.protocol_centrifugation_tier (Centrifugation Application Tier): Formatted display string (e.g. 'Microcentrifuge (DNA / RNA / Protein Pelleting)')

      • metrics.radius_variance_factor (Rotor Radius Metric): Formatted display string (e.g. '85 mm Radius')

    • execution_time_ms (number): Latency in milliseconds.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "omni_centrifuge_rcf_g_force"
  }
}

Input Schema

NameRequiredDescriptionDefault
rotor_radius_centimetersNoRotor Radius (r in cm) (cm). Distance from center of centrifuge spindle to bottom of tube bucket. Default: 8.5. Min: 1. Max: 50.
centrifuge_rotor_speed_rpmNoRotational Speed (RPM) (RPM). Rotor revolutions per minute. Default: 14000. Min: 100. Max: 100000.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Addedv0.1.2

TDQS

Score is being calculated.

Deploy Server

Other Tools