omni_solar_inverter_clipping
Calculate DC-to-AC inverter loading ratio, annual energy clipping loss, and inverter size selection for photovoltaic systems from array and inverter ratings.
Instructions
Solar Inverter Sizing & DC-to-AC Overload Clipping Ratio. Calculate DC-to-AC inverter loading ratio (ILR), annual energy clipping loss percentage, and inverter size optimization for photovoltaic systems. Discipline: ENERGY. Governing mathematical model / formula: DC-to-AC Ratio (ILR) = Total DC Module Nameplate kW / Inverter Max Rated AC Output kW.
USAGE GUIDELINES:
WHEN TO USE: Invoke for deterministic calculation of ilr_ratio (DC-to-AC Loading Ratio (ILR)), clipping_status (Clipping Design Evaluation), estimated_clip_loss (Estimated Annual Clipping Loss), max_ac_current (Max Continuous AC Current (240V)) using dc_array_kw (Total DC Solar Array (kW DC) in kW DC), ac_inverter_kw (Inverter AC Nameplate Output (kW AC) in kW AC), inverter_eff_pct (Inverter CEC Weighted Efficiency (%) in %). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.
WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.
DISAMBIGUATION & BOUNDARIES:
Use this dedicated specialist tool for 'Solar Inverter Sizing & DC-to-AC Overload Clipping Ratio' rather than generic dispatchers like omni_universal_query.
For multi-calculation chained jobs, use 'omni_batch_calculate'.
To inspect schema fields, see 'omni_describe_solver'.
BEHAVIOR & SAFETY:
Pure deterministic computation with machine floating-point precision.
Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.
Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.
RETURNS:
Structured JSON object containing:
status (string): "success" on valid execution or "error" if validation fails
calculator (string): "solar-inverter-clipping"
category (string): "energy"
name (string): "Solar Inverter Sizing & DC-to-AC Overload Clipping Ratio"
formula (string): Governing mathematical formula string
inputs (object): Echoed input parameter dictionary with applied defaults
metrics (object): Dictionary of computed outputs:
metrics.ilr_ratio (DC-to-AC Loading Ratio (ILR)): Formatted display string (e.g. '1.35')
metrics.clipping_status (Clipping Design Evaluation): Formatted display string (e.g. 'Optimal Commercial Ratio')
metrics.estimated_clip_loss (Estimated Annual Clipping Loss): Formatted display string (e.g. '1.2% (< 140 kWh/yr)')
metrics.max_ac_current (Max Continuous AC Current (240V)): Formatted display string (e.g. '31.7 Amps')
execution_time_ms (number): Latency in milliseconds.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "omni_solar_inverter_clipping"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| dc_array_kw | No | Total DC Solar Array (kW DC) (kW DC). Sum of nameplate wattage of all installed modules. Default: 10.25. Min: 2. Max: 100. | |
| ac_inverter_kw | No | Inverter AC Nameplate Output (kW AC) (kW AC). Continuous AC power limit (e.g. 7.6 kW standard). Default: 7.6. Min: 2. Max: 80. | |
| inverter_eff_pct | No | Inverter CEC Weighted Efficiency (%) (%). California Energy Commission efficiency rating. Default: 97.5. Min: 92. Max: 99.5. |