omni_battery_backup_storage
Calculate home battery backup runtime and usable stored energy from battery capacity, depth of discharge, inverter efficiency, continuous load, and daily solar recharge.
Instructions
Home Battery Backup Duration & Storage Calculator. Calculate backup run-time duration in hours and days for home battery systems (Tesla Powerwall, Enphase, SolarEdge) under essential or whole-home load. Discipline: ENERGY. Governing mathematical model / formula: Backup Hours = (Usable Battery kWh × Depth of Discharge × Inverter Efficiency) / Continuous Load kW.
USAGE GUIDELINES:
WHEN TO USE: Invoke for deterministic calculation of zero_solar_hours (Standalone Runtime (No Solar)), net_daily_duration (Off-Grid Resilience Horizon), usable_stored_kwh (Usable Stored AC Energy), daily_load_kwh (24-Hour Energy Consumption) using battery_capacity_kwh (Nominal Battery Capacity (kWh) in kWh), dod_pct (Max Depth of Discharge (DoD %) in %), continuous_load_w (Average Critical Load (Watts) in W), solar_recharge_kwh (Daily Solar Recharge Input (kWh/day) in kWh/day), inverter_eff_pct (Inverter Round-Trip Efficiency (%) in %). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.
WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.
DISAMBIGUATION & BOUNDARIES:
Use this dedicated specialist tool for 'Home Battery Backup Duration & Storage Calculator' rather than generic dispatchers like omni_universal_query.
For multi-calculation chained jobs, use 'omni_batch_calculate'.
To inspect schema fields, see 'omni_describe_solver'.
BEHAVIOR & SAFETY:
Pure deterministic computation with machine floating-point precision.
Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.
Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.
RETURNS:
Structured JSON object containing:
status (string): "success" on valid execution or "error" if validation fails
calculator (string): "battery-backup-storage"
category (string): "energy"
name (string): "Home Battery Backup Duration & Storage Calculator"
formula (string): Governing mathematical formula string
inputs (object): Echoed input parameter dictionary with applied defaults
metrics (object): Dictionary of computed outputs:
metrics.zero_solar_hours (Standalone Runtime (No Solar)): Formatted display string (e.g. '12.8 hours')
metrics.net_daily_duration (Off-Grid Resilience Horizon): Formatted display string (e.g. 'Indefinite (> 7 days)')
metrics.usable_stored_kwh (Usable Stored AC Energy): Formatted display string (e.g. '23.1 kWh')
metrics.daily_load_kwh (24-Hour Energy Consumption): Formatted display string (e.g. '43.2 kWh')
execution_time_ms (number): Latency in milliseconds.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "omni_battery_backup_storage"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| dod_pct | No | Max Depth of Discharge (DoD %) (%). Manufacturer usable battery reserve. Default: 95. Min: 80. Max: 100. | |
| inverter_eff_pct | No | Inverter Round-Trip Efficiency (%) (%). DC-to-AC and battery round-trip efficiency. Default: 90. Min: 80. Max: 98. | |
| continuous_load_w | No | Average Critical Load (Watts) (W). Sump pump, refrigerator, lighting, router, essentials. Default: 1800. Min: 200. Max: 15000. | |
| solar_recharge_kwh | No | Daily Solar Recharge Input (kWh/day) (kWh/day). Solar energy replenishment during daylight. Default: 15. Min: 0. Max: 60. | |
| battery_capacity_kwh | No | Nominal Battery Capacity (kWh) (kWh). Total battery pack energy (e.g. 2x Powerwall = 27 kWh). Default: 27. Min: 3. Max: 100. |