omni_power_factor_correction

Calculate required capacitor kVAR bank size to correct lagging three-phase power factor, reduce line current, and avoid utility penalty surcharges from inductive loads.

Instructions

3-Phase Power Factor Correction & Capacitor Sizing Calculator. Calculate required capacitor kVAR bank size to correct lagging electrical power factor from inductive motors, eliminating utility penalty surcharges. Discipline: ENERGY. Governing mathematical model / formula: Required kVAR = P × (tan(θ₁) - tan(θ₂)) | θ = arccos(PF).

USAGE GUIDELINES:

  • WHEN TO USE: Invoke for deterministic calculation of required_kvar (Capacitor Bank Required), current_reduction (Line Current Reduction), original_kva (Original Apparent Power), corrected_kva (Corrected Apparent Power) using active_power_kw (Active Real Power (kW) in kW), current_pf (Current Measured Power Factor), target_pf (Target Corrected Power Factor), voltage_ll (Line-to-Line Voltage (Volts AC) in V). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.

  • WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.

  • SIBLING ROUTING: Use this dedicated specialist tool for '3-Phase Power Factor Correction & Capacitor Sizing Calculator' rather than generic dispatchers like omni_universal_query. For cross-discipline dynamic dispatch, see omni_universal_query.

BEHAVIOR & SAFETY:

  • Pure deterministic computation with machine floating-point precision.

  • Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.

  • Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.

RETURNS:

  • Structured JSON object containing:

    • status (string): "success" on valid execution or "error" if validation fails

    • calculator (string): "power-factor-correction"

    • category (string): "energy"

    • name (string): "3-Phase Power Factor Correction & Capacitor Sizing Calculator"

    • formula (string): Governing mathematical formula string

    • inputs (object): Echoed input parameter dictionary with applied defaults

    • metrics (object): Dictionary of computed outputs:

      • metrics.required_kvar (Capacitor Bank Required): Formatted display string (e.g. '131.5 kVAR')

      • metrics.current_reduction (Line Current Reduction): Formatted display string (e.g. '79.2 Amps')

      • metrics.original_kva (Original Apparent Power): Formatted display string (e.g. '328.9 kVA')

      • metrics.corrected_kva (Corrected Apparent Power): Formatted display string (e.g. '263.2 kVA')

    • execution_time_ms (number): Latency in milliseconds.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "omni_power_factor_correction"
  }
}

Input Schema

NameRequiredDescriptionDefault
target_pfNoTarget Corrected Power Factor. Desired power factor to avoid utility penalties (typically 0.95). Default: 0.95. Min: 0.85. Max: 1.
current_pfNoCurrent Measured Power Factor. Uncorrected lagging power factor (cos θ₁). Default: 0.76. Min: 0.5. Max: 0.95.
voltage_llNoLine-to-Line Voltage (Volts AC) (V). 3-phase service voltage. Default: 480. Min: 208. Max: 4160.
active_power_kwNoActive Real Power (kW) (kW). Actual working power consumed by facility loads. Default: 250. Min: 10. Max: 10000.