omni_thermal_expansion_bridge_joints
Calculate bridge thermal movement and size expansion joint seals under AASHTO LRFD from expansion length, material, and design temperatures, returning recommended joint type and installation gap.
Instructions
Bridge Superstructure Thermal Expansion & Expansion Joint Sizing Calculator. Calculate total thermal movement (expansion and contraction ΔL in inches) and select bridge expansion joint seals (strip seal, modular joint) under AASHTO LRFD. Discipline: ENGINEERING. Governing mathematical model / formula: Thermal Movement ΔL = α · L · ΔT | Steel α = 6.5 × 10⁻⁶ /°F, Concrete α = 6.0 × 10⁻⁶ /°F.
USAGE GUIDELINES:
WHEN TO USE: Invoke for deterministic calculation of total_thermal_movement_in (Total Thermal Movement Range (ΔL)), recommended_joint_type (Recommended Expansion Joint), effective_temperature_range (Design Temperature Range (ΔT)), installation_gap_at_60f (Target Setting Gap @ 60°F) using bridge_expansion_length_ft (Bridge Continuous Expansion Length (Feet) in ft), superstructure_material (Superstructure Material (1 = Structural Steel, 2 = Prestressed Concrete)), max_design_temp_f (Maximum Design Summer Temperature (°F) in °F), min_design_temp_f (Minimum Design Winter Temperature (°F) in °F). Guarantees exact machine floating-point precision, eliminating LLM arithmetic mistakes and formula hallucinations.
WHEN NOT TO USE: Do not use for qualitative evaluations or unquantified reasoning. All input parameters must be valid numerical values.
DISAMBIGUATION & BOUNDARIES:
Use this dedicated specialist tool for 'Bridge Superstructure Thermal Expansion & Expansion Joint Sizing Calculator' rather than generic dispatchers like omni_universal_query.
For multi-calculation chained jobs, use 'omni_batch_calculate'.
To inspect schema fields, see 'omni_describe_solver'.
BEHAVIOR & SAFETY:
Pure deterministic computation with machine floating-point precision.
Read-only, idempotent, and stateless. Zero side effects or persistent state mutations.
Input validation: All arguments are validated against physical and domain bounds. Out-of-bounds inputs return a safe diagnostic error status without throwing runtime exceptions.
RETURNS:
Structured JSON object containing:
status (string): "success" on valid execution or "error" if validation fails
calculator (string): "thermal-expansion-bridge-joints"
category (string): "engineering"
name (string): "Bridge Superstructure Thermal Expansion & Expansion Joint Sizing Calculator"
formula (string): Governing mathematical formula string
inputs (object): Echoed input parameter dictionary with applied defaults
metrics (object): Dictionary of computed outputs:
metrics.total_thermal_movement_in (Total Thermal Movement Range (ΔL)): Formatted display string (e.g. '3.28 Inches')
metrics.recommended_joint_type (Recommended Expansion Joint): Formatted display string (e.g. 'Strip Seal Joint (Up to 4.0" movement)')
metrics.effective_temperature_range (Design Temperature Range (ΔT)): Formatted display string (e.g. '120.0°F Range')
metrics.installation_gap_at_60f (Target Setting Gap @ 60°F): Formatted display string (e.g. '1.91 Inches Setting Gap')
execution_time_ms (number): Latency in milliseconds.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "omni_thermal_expansion_bridge_joints"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| max_design_temp_f | No | Maximum Design Summer Temperature (°F) (°F). AASHTO maximum bridge deck temperature. Default: 110. Min: 85. Max: 130. | |
| min_design_temp_f | No | Minimum Design Winter Temperature (°F) (°F). AASHTO minimum bridge deck temperature. Default: -10. Min: -40. Max: 30. | |
| superstructure_material | No | Superstructure Material (1 = Structural Steel, 2 = Prestressed Concrete). 1: Steel (α = 0.0000065/°F), 2: Concrete (α = 0.0000060/°F). Default: 1. Min: 1. Max: 2. | |
| bridge_expansion_length_ft | No | Bridge Continuous Expansion Length (Feet) (ft). Distance from fixed bearing to expansion joint. Default: 350. Min: 25. Max: 2500. |