Skip to main content
Glama
eng-toolkit

eng-toolkit

by Lin830326

Thermal Transient

thermal_transient

Calculate transient heat conduction and temperature response after a sudden ambient change, including time to target temperature and cooling/heating tables for lumped and solid shapes.

Instructions

Transient conduction after a sudden change of the surroundings. model='lumped': lumped capacitance with the Biot check (warns above 0.1), time constant tau, T(t), the time to reach a target temperature, and (lumped only) a warm-up with a constant 'heat_input' (e.g. '8 W'): give 'times' (list) or 't_end' with 'points' and ONE call returns the whole T(t) table (CSV temperature_vs_time.csv, time in s) plus tau and the final temperature. model='plane_wall' | 'cylinder' | 'sphere': one-term series (Biot, Fourier number, warns below 0.2). model='semi_infinite': T(depth, time) by erf/erfc or contact temperature. Temperatures are absolute. Give 'time' or 'target_temperature' (or the table inputs for lumped).

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "model": "<model>",
      "initial_temperature": "<initial_temperature>",
      "ambient_temperature": "<ambient_temperature>",
      "conductivity": "<conductivity>",
      "density": "<density>",
      "specific_heat": "<specific_heat>"
    },
    "name": "thermal_transient"
  }
}

Input Schema

NameRequiredDescriptionDefault
hNoConvection coefficient, e.g. '100 W/(m^2*K)' (all models except semi_infinite with fixed_temperature / contact)
sizeNoplane_wall: HALF the thickness; cylinder / sphere: the radius, e.g. '10 mm'
timeNoElapsed time, e.g. '120 s'. Give this or 'target_temperature'.
depthNosemi_infinite: depth below the surface, e.g. '5 mm' (blank = at the surface)
modelYes'lumped', 'plane_wall', 'cylinder', 'sphere' or 'semi_infinite'
t_endNolumped table: end time, e.g. '3600 s'; rows are spaced evenly from 0 s to t_end ('points' of them)
timesNolumped table: list of times, e.g. '0 s; 60 s; 600 s' or a JSON array of such strings. Ascending, <= 2000 entries.
pointsNolumped table with 't_end': number of rows including 0 s and t_end, 2..2000
volumeNolumped only: body volume, e.g. '1e-4 m^3'
densityYesBody density, e.g. '7800 kg/m^3'
positionNoplane_wall / cylinder / sphere: location as a fraction of 'size', 0 = centre (default), 1 = surface
heat_inputNolumped only: constant heat power into the body, e.g. '8 W' (blank = 0, a pure cool-down). Steady state is Tinf + Q/(h As).
unit_systemNoUnit system of the results: 'metric' (degC, W, m, W/m2/K) or 'imperial' (degF, Btu/h, ft, Btu/h/ft2/degF)metric
conductivityYesBody conductivity, e.g. '15 W/(m*K)'
surface_areaNolumped only: surface area exposed to the fluid, e.g. '0.03 m^2'
other_densityNocontact: density of the other body
specific_heatYesBody specific heat, e.g. '500 J/(kg*K)'
body_thicknessNosemi_infinite, optional: real thickness of the body, to check the semi-infinite assumption
other_temperatureNocontact: initial temperature of the other semi-infinite body
surface_conditionNosemi_infinite: 'fixed_temperature' (default), 'convection' (needs h) or 'contact' (needs the other_* inputs)fixed_temperature
other_conductivityNocontact: conductivity of the other body
target_temperatureNoLumped / series only: temperature to reach (between initial and ambient); returns the time instead
ambient_temperatureYesFluid temperature after the step, e.g. '20 degC' (semi_infinite with fixed_temperature: the imposed surface temperature; with contact: not used)
initial_temperatureYesUniform initial temperature of the body, e.g. '200 degC'
other_specific_heatNocontact: specific heat of the other body

Output Schema

NameRequiredDescriptionDefault
okYes
dataNoNon-quantity payload (reports, listings)
errorNo
valueNoPrimary quantity result
valuesNoAll named quantity results (includes the primary)
warningsNo
artifactsNo
provenanceYesWhat produced the result and from which inputs.
review_statusNounreviewed

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.0.1

TDQS

A3.9/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description carries the full burden and does well: it discloses validity warnings (Biot check warns above 0.1 for lumped, one-term series warns below 0.2), the numeric cap of 2000 table entries/rows, the CSV artifact name and its time unit, and the steady-state limit Tinf + Q/(h*As) for heat_input. Remaining gaps are failure behavior for out-of-range inputs and unit-consistency handling.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness3/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The length is justified by five models and 25 parameters, and the front-loading with 'model=lumped' is good. However, it is delivered as one dense run-on paragraph that interleaves model rules, input routing, and output artifacts, making it hard to scan; per-model separation would cost nothing and gain a lot.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a tool this complex the description covers the essentials: model taxonomy, input routing, validity limits, and output artifact. Since an output schema exists, return-value detail is rightly not duplicated. Minor omission: it never states that lumped additionally needs volume and surface_area, which an agent could miss when assembling a lumped call.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100%, so the baseline is 3, but the description adds genuine meaning on top: it groups parameters by model so the agent knows which of the 25 fields are live in a given call, defines 'heat_input' as a constant power with blank meaning pure cool-down, and clarifies that temperatures are absolute. It does not restate schema text verbatim.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

Opens with a specific phenomenon (transient conduction after a step change in surroundings) and then enumerates the five supported solution models, each with its own physics (lumped, one-term series, semi-infinite erf/erfc/contact). This is far more specific than the bare name 'thermal_transient'. It does not explicitly name which sibling to prefer instead (e.g. thermal_conduction), so it falls short of a 5.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Gives real selection guidance: which inputs each model needs ('lumped only', 'semi_infinite with fixed_temperature / contact'), and 'Give time or target_temperature (or the table inputs for lumped)'. It clearly encodes mutually exclusive input paths. It lacks an explicit statement of when to use this tool versus the steady-state thermal_conduction sibling.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server

Other Tools