Structures3D Foundation

structures3d_foundation

Solve constant-EI Euler-Bernoulli beams on linear Winkler foundations with free, pinned, or fixed ends and point/uniform loads, returning shear/moment equilibrium, CSV output, and mesh convergence.

Instructions

Finite constant-EI Euler-Bernoulli beam on a linear Winkler foundation. Free/pinned/fixed ends, uniform load and point forces/moments, consistent Hermite foundation stiffness, equilibrium M/V, CSV and bounded mesh convergence. Bilateral springs carry tension; no uplift/contact or nonlinear soil.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "structures3d_foundation"
  }
}

Input Schema

NameRequiredDescriptionDefault
lengthNoBeam span with units, e.g. '10 m'.
elementsNoInitial Hermite elements, 1..200; include all point locations; doubles automatically up to 200 for convergence.
left_endNoLeft end: free, pinned or fixed; zero prescribed movement.free
stationsNoUniform table stations, 2..2001; mesh ends and FE extrema are added.
right_endNoRight end: free, pinned or fixed; zero prescribed movement.free
point_loadsNoRecords 'x,force,moment', e.g. '5 m,20 kN,0 N*m'; moment acts along positive slope; at most 100; '' omits.
unit_systemNoOutput units: metric (m, N, Pa) or imperial (inch, lbf, psi). CSV columns explicitly name their units.metric
uniform_loadNoSigned constant transverse load, e.g. '10 kN/m'; positive along deflection.0 N/m
foundation_modelNoOnly 'linear' bilateral Winkler springs are supported.linear
flexural_rigidityNoConstant EI with units, e.g. '2e7 N*m^2'.
foundation_stiffnessNoPositive spring stiffness per beam length, e.g. '1e6 N/m^2'; include tributary width.
convergence_toleranceNoRelative two-mesh change threshold, 1e-6..0.2; default 0.01.

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.0.1

TDQS

A3.7/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description carries the full behavioral burden and does a good job disclosing key constraints: bilateral springs carry tension, no uplift/contact or nonlinear soil, bounded mesh convergence with automatic doubling up to 200 elements, and CSV output including equilibrium M/V. It does not discuss computational cost or which inputs are practically required, but for a deterministic solver the important behavioral traits are covered.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Two dense sentences with the core model statement front-loaded and no filler. The subsequent capability and limitation list is compact and earns its place, though the second sentence is a long enumeration rather than optimally structured.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 12-parameter finite-element solver with no output schema and no annotations, the description supplies the model scope, supported features, convergence behavior, and exclusions. It does not clarify which empty-default parameters are effectively required or describe the CSV contents in detail, but it is otherwise complete enough to call the tool correctly.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, so all 12 parameters are fully documented in the input schema. The description restates the supported load types, end conditions, and linear foundation model but adds no syntax, formatting, or constraint detail beyond what the schema already provides, so the baseline 3 is appropriate.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names the exact physics model: a constant-EI Euler-Bernoulli beam on a linear Winkler foundation, and enumerates supported boundary conditions, loads, internal force output, and convergence behavior. It is specific enough that an agent knows what analysis this tool performs, though it does not explicitly distinguish itself from siblings such as structures3d_static.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Usage is implied by the model description rather than stated. The description does provide partial when-not guidance by excluding uplift/contact and nonlinear soil, but it never names an alternative tool or gives an explicit condition for choosing this beam-on-foundation solver over another structural tool.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.