Skip to main content
Glama
eng-toolkit

eng-toolkit

by Lin830326

Structures Column

structures_column

Calculate Euler/Johnson column buckling loads, slenderness, and safety factors, including secant-formula eccentric yield checks for prismatic columns.

Instructions

Euler and Johnson column buckling, slenderness, secant-formula eccentric yield load and safety. Standard effective lengths include fixed-pinned K=0.6992 from tan(z)=z. Prismatic straight column, linear elastic material; Johnson is an inelastic empirical estimate. No AISC/Eurocode check.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "structures_column"
  }
}

Input Schema

NameRequiredDescriptionDefault
areaNoRequired cross-sectional area carrying compression, e.g. '1000 mm^2'.
lengthNoRequired unsupported column length before applying K, e.g. '2 m'.
inertiaNoRequired second moment of area about the buckling axis, e.g. '1e6 mm^4'.
unit_systemNoOutput units: metric (m, N, Pa) or imperial (inch, lbf, psi). CSV columns explicitly name their units.metric
applied_loadNoNonnegative compressive load for safety factor and secant stress, e.g. '50 kN'; '' omits demand checks.
eccentricityNoNonnegative load offset for pinned-pinned secant analysis, e.g. '5 mm'; requires extreme_fibre and yield_strength; '' omits.
end_conditionNopinned-pinned, fixed-free, fixed-pinned, fixed-fixed, or custom.pinned-pinned
extreme_fibreNoCentroid-to-extreme-fibre distance on the bending axis, e.g. '50 mm'; required with eccentricity; '' omits.
yield_strengthNoCompressive yield stress for Johnson and secant checks, e.g. '250 MPa'; '' omits; required with eccentricity.
youngs_modulusNoRequired elastic Young's modulus for buckling, e.g. '200 GPa'.
effective_length_factorNoDimensionless K for custom ends, e.g. 0.8; required in (0,10] for custom; leave 0 for standard ends.

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.0.1

TDQS

A3.8/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations supplied, the description carries the full burden and does meaningful work: it discloses the governing physical assumptions (prismatic, straight, linear elastic), flags Johnson as an inelastic empirical estimate rather than an exact solution, and explicitly warns there is no AISC/Eurocode compliance check. It does not describe error behavior, missing-parameter handling, or output format, which keeps it below 5.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The description is four compact sentences, front-loaded with the purpose and then the limit conditions. Every sentence carries information; the citation of K=0.6992 from tan(z)=z is ornamental but small enough not to be wasteful.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For an 11-parameter analysis tool with no annotations and no output schema, the definition is adequate: the schema documents every parameter including the empty-string omission semantics and the CSV unit behavior, while the description supplies the modeling assumptions and the code-compliance caveat an agent needs to select and call it correctly.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, so every parameter is already documented in the schema, and the baseline is 3. The description adds marginal meaning by naming standard end conditions and citing the fixed-pinned K=0.6992 value, which lends context to end_condition and effective_length_factor, but it does not explain the custom end-condition path or the interaction between eccentricity, extreme_fibre, and yield_strength.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names specific analyses (Euler buckling, Johnson buckling, slenderness, secant-formula eccentric load, safety factor), which is far more than a restatement of the title and clearly distinguishes it from siblings like structures_frame or structures_stress. It stops short of any explicit sibling comparison, so a 4 rather than a 5.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Usage context is implied through scope limits rather than stated: 'prismatic straight column, linear elastic material' and 'No AISC/Eurocode check' tell the agent when this model is not appropriate. There is no positive statement of when to pick this over structures_frame or structures_section, and no prerequisites are given.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server