Skip to main content
Glama
eng-toolkit

eng-toolkit

by Lin830326

Thermal Radiation

thermal_radiation

Calculate net radiation heat exchange between diffuse grey surfaces for parallel plates, concentric cylinders or spheres, and small bodies in enclosures, with optional radiation shields.

Instructions

Net radiation heat exchange between two diffuse grey surfaces at uniform absolute temperatures: 'parallel_plates' (infinite, area A), 'concentric_cylinders' (long; inner radius, outer radius, length), 'concentric_spheres', or 'small_body_in_enclosure' (q = e sigma A (T1^4 - T2^4)). Parallel plates accept N radiation shields. Returns net heat rate (positive from surface 1 to surface 2), effective emissivity, the equivalent radiation coefficient h_r = q/(A1 (T1 - T2)), shield temperatures, and the assumptions.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "configuration": "<configuration>",
      "temperature_1": "<temperature_1>",
      "temperature_2": "<temperature_2>",
      "emissivity_1": "<emissivity_1>"
    },
    "name": "thermal_radiation"
  }
}

Input Schema

NameRequiredDescriptionDefault
areaNoparallel_plates: plate area; small_body_in_enclosure: area of the body (surface 1). e.g. '2 m^2'
lengthNoconcentric cylinders: length, e.g. '2 m'
shieldsNoparallel_plates only: number of radiation shields between the plates (default 0)
unit_systemNoUnit system of the results: 'metric' (degC, W, m, W/m2/K) or 'imperial' (degF, Btu/h, ft, Btu/h/ft2/degF)metric
emissivity_1YesEmissivity of surface 1, 0 < e <= 1, e.g. 0.8
emissivity_2NoEmissivity of surface 2 (ignored for small_body_in_enclosure; give any value in (0, 1], e.g. 1), 0 < e <= 1
inner_radiusNoconcentric cylinders / spheres: radius of surface 1, e.g. '50 mm'
outer_radiusNoconcentric cylinders / spheres: radius of surface 2 (> inner), e.g. '100 mm'
configurationYes'parallel_plates', 'concentric_cylinders', 'concentric_spheres' or 'small_body_in_enclosure'
temperature_1YesAbsolute temperature of surface 1 (the plate / the inner body), e.g. '600 K'
temperature_2YesAbsolute temperature of surface 2 (the other plate / the enclosure), e.g. '300 K'
shield_emissivityNoEmissivity of each shield (both faces). 0 = same as emissivity_1 and emissivity_2 only if those are equal; otherwise give it. 0 < e <= 1

Output Schema

NameRequiredDescriptionDefault
okYes
dataNoNon-quantity payload (reports, listings)
errorNo
valueNoPrimary quantity result
valuesNoAll named quantity results (includes the primary)
warningsNo
artifactsNo
provenanceYesWhat produced the result and from which inputs.
review_statusNounreviewed

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.0.1

TDQS

A4.2/5.0
Behavior5/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations provided, the description carries the full behavioral burden and does so well: it states the diffuse-grey, uniform-temperature assumptions, notes infinite parallel plates and long cylinders, explains that parallel plates accept shields, and gives the small-body formula. It also defines the sign convention for net heat rate, the returned quantities, and that assumptions are returned. These details give an agent substantial insight into how the calculation behaves.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness5/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The description is front-loaded with the tool's purpose and then efficiently lists configurations, shield support, and outputs. Despite covering many parameters and return values, it avoids filler and keeps each clause informative. The structure is dense but purposeful.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 12-parameter thermal calculation tool with multiple geometry modes, the description covers the relevant configurations, key assumptions, shield behavior, and output meaning. Although an output schema exists, the description still usefully defines the sign convention and key returned quantities. An agent has enough context to invoke the tool correctly across the major supported cases.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is already 100%, so the baseline would be 3, but the description adds cross-parameter meaning by mapping area, radii, length, and shields to specific configurations. It also clarifies that the small-body case uses q = e sigma A (T1^4 - T2^4), reinforcing how parameters interact. The schema still does most of the detailed parameter documentation, which is why this is not a 5.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description clearly states a specific physical calculation: net radiation heat exchange between two diffuse grey surfaces at uniform absolute temperatures. It enumerates the supported geometries, so an agent can understand what the tool computes. It does not explicitly contrast itself with sibling tools such as thermal_convection or thermal_conduction, which keeps it from a 5.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

The configuration names imply which geometry each calculation applies to, and the note that parallel plates accept radiation shields gives one conditional usage detail. However, there is no explicit guidance on when to choose this tool over sibling thermal tools or when each configuration should be avoided. The guidance is therefore implied rather than stated.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server

Other Tools