Fluids Surge
fluids_surgeCalculate water-hammer surge pressures and transient pipe flow with Joukowsky/Michaud estimates or method-of-characteristics simulation, and export reach/location results to CSV.
Instructions
Thin-wall elastic wave speed, Joukowsky surge, Michaud slow-closure estimate and reservoir-pipe-valve MOC CSV. Linear valve-area closure, friction neglected; Courant=1. D/e>=20; <=200 reaches, 20000 steps and 2 million reach-steps. No cavitation/column-separation model.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "fluids_surge"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| length | No | Reservoir-to-valve pipe length, e.g. '1000 m'; required for estimates and simulation. | |
| density | No | Fluid mass density, e.g. '1000 kg/m^3'; all modes; default is a nominal water input, not a property correlation. | 1000 kg/m^3 |
| reaches | No | Equal pipe reaches for MOC, 2..200; default 40; ignored for estimate-only calls. | |
| diameter | No | Pipe inside diameter, e.g. '0.5 m'; required in all modes. | |
| duration | No | MOC simulation duration, e.g. '5 s'; '' returns estimates only; actual final time rounds up by less than one step. | |
| anchoring | No | expansion_joints (c1=1), restrained (1-nu^2), or upstream_anchor (1-nu/2). | restrained |
| locations | No | MOC output positions, e.g. '0 m;500 m'; <=20 records, nearest grid point reported; '' selects 0,L/2,L. | |
| time_step | No | MOC time step, e.g. '0.01 s'; '' uses dx/a; supplied value must satisfy Courant=1 within 1e-8. | |
| bulk_modulus | No | Fluid bulk modulus, e.g. '2.2 GPa'; required for elastic wave speed. | |
| closure_time | No | Time for linear valve-area closure, e.g. '1 s'; required; '0 s' means instantaneous closure. | |
| poisson_ratio | No | Pipe-wall Poisson ratio nu, e.g. 0.3; all anchoring cases, 0..0.49. | |
| reservoir_head | No | Reservoir head above valve outlet, e.g. '100 m'; required for MOC, '' for estimates only; horizontal pipe. | |
| wall_thickness | No | Elastic pipe wall thickness, e.g. '10 mm'; required, thickness/diameter<=0.05. | |
| youngs_modulus | No | Pipe-wall Young's modulus, e.g. '200 GPa'; required for elastic compliance. | |
| initial_velocity | No | Forward velocity before complete valve closure, e.g. '1 m/s'; required and positive. | |
| dynamic_viscosity | No | Fluid dynamic viscosity, e.g. '1 mPa*s'; all modes; '' requires kinematic_viscosity instead. | 1 mPa*s |
| kinematic_viscosity | No | Fluid kinematic viscosity, e.g. '1 cSt'; '' omits; supply only when dynamic_viscosity is ''. |