Skip to main content
Glama
eng-toolkit

eng-toolkit

by Lin830326

Machine Belt

machine_belt

Calculate flat or V-belt drive length, wrap angle, tension ratios, limiting power, and preload from pulley sizes and speed or power.

Instructions

Flat/V belt drive: open or crossed length, wrap, Euler capstan ratio, centrifugal tension, limiting power and inverse tensions/preload. Give velocity OR small-pulley speed; power OR effective tight_tension. V groove_angle is the included angle. Optional maximum total tension gives maximum-power speed. No slip/creep model.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "small_diameter": "<small_diameter>",
      "large_diameter": "<large_diameter>",
      "centre_distance": "<centre_distance>"
    },
    "name": "machine_belt"
  }
}

Input Schema

NameRequiredDescriptionDefault
powerNoPhysical quantity with unit, e.g. '25 mm', '100 N*m', '200 MPa'; optional inputs use ''.
speedNoPhysical quantity with unit, e.g. '25 mm', '100 N*m', '200 MPa'; optional inputs use ''.
frictionNoFinite dimensionless coefficient; zero selects the documented automatic value where supported.
velocityNoPhysical quantity with unit, e.g. '25 mm', '100 N*m', '200 MPa'; optional inputs use ''.
belt_typeNo'flat' or 'v'; V friction uses the included groove_angle.flat
unit_systemNoOutput units: 'metric' (mm, N, MPa) or 'imperial' (inch, lbf, ksi).metric
groove_angleNoPhysical quantity with unit, e.g. '25 mm', '100 N*m', '200 MPa'; optional inputs use ''.40 deg
configurationNo'open' (same rotation) or 'crossed' (opposite rotation); crossed V belts are refused.open
tight_tensionNoEffective tight-side traction tension, exclusive of m*v^2, e.g. '300 N'; give this OR power.
large_diameterYesPhysical quantity with unit, e.g. '25 mm', '100 N*m', '200 MPa'; optional inputs use ''.
small_diameterYesPhysical quantity with unit, e.g. '25 mm', '100 N*m', '200 MPa'; optional inputs use ''.
centre_distanceYesPhysical quantity with unit, e.g. '25 mm', '100 N*m', '200 MPa'; optional inputs use ''.
mass_per_lengthNoPhysical quantity with unit, e.g. '25 mm', '100 N*m', '200 MPa'; optional inputs use ''.
maximum_tensionNoOptional maximum TOTAL belt tension including centrifugal tension, e.g. '1 kN'; requires mass_per_length for optimum speed.

Output Schema

NameRequiredDescriptionDefault
okYes
dataNoNon-quantity payload (reports, listings)
errorNo
valueNoPrimary quantity result
valuesNoAll named quantity results (includes the primary)
warningsNo
artifactsNo
provenanceYesWhat produced the result and from which inputs.
review_statusNounreviewed

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.0.1

TDQS

A4.1/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description carries the behavioral burden itself and discloses meaningful model assumptions: Euler capstan ratio, centrifugal tension, limiting power, inverse tensions/preload, V included angle, maximum-power speed from maximum total tension, and no slip/creep model. It does not cover validation errors or special refusals such as crossed V belts, which are left to the schema rather than annotations.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness5/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The description is compact and front-loaded with the domain and calculated outputs, followed by input-combination rules, special V behavior, and the model limitation. It is dense and technical but every sentence carries relevant information with no filler.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 14-parameter calculation tool with full schema description coverage and an output schema, the description covers the core calculation modes, key input choices, and the no-slip limitation. It omits some schema-level details such as crossed V-belt refusal and zero-friction automatic handling, but those are available in the structured schema.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100%, so the baseline is 3, but the description adds useful relational meaning: velocity OR small-pulley speed, power OR effective tight_tension, groove_angle as the included V angle, and maximum total tension enabling maximum-power speed. Some of this is repeated in the schema descriptions, but the OR-group semantics meaningfully supplement it.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description identifies the specific domain as a flat/V belt-drive calculation and lists the quantities computed: length, wrap, Euler ratio, centrifugal tension, limiting power, tensions/preload. The resource is distinct from sibling machine tools such as gears, shafts, and welds, though it uses a noun-phrase list rather than an explicit verb like 'calculate'.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

It gives clear input-combination guidance: 'Give velocity OR small-pulley speed; power OR effective tight_tension.' It also states an important exclusion, 'No slip/creep model,' but does not offer broader when-to-use versus when-not-to-use framing beyond the calculation domain.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server