Fluids Open Channel
fluids_open_channelCompute Manning open-channel flow for rectangular, trapezoidal, triangular, and circular sections, including normal/critical depths, Froude regime, hydraulic jumps, and GVF profiles.
Instructions
Rectangular/trapezoidal/triangular/part-full circular Manning flow, normal/critical/alternate depths, Froude regime, Belanger or momentum jump, standard-step GVF CSV. SI Manning conversion, bracketed roots; <=500 profile steps. Circular dual normal-depth branches explicit; no pressurized or transcritical profile.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "fluids_open_channel"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| mode | No | analysis (given discharge), uniform (compute discharge at depth), or profile (given boundary depth and discharge). | analysis |
| depth | No | Flow depth, e.g. '0.5 m'; required for uniform; '' uses normal depth in analysis; omit for profile. | |
| shape | No | rectangular, trapezoidal, triangular, or circular; prismatic section throughout. | rectangular |
| width | No | Channel bottom width, e.g. '2 m'; required for rectangular/trapezoidal, '' for triangular/circular. | |
| density | No | Fluid mass density, e.g. '1000 kg/m^3'; all modes; default is a nominal water input, not a property correlation. | 1000 kg/m^3 |
| diameter | No | Circular inside diameter, e.g. '1 m'; required only for circular, '' for open polygonal sections. | |
| bed_slope | No | Bed fall per horizontal length, e.g. 0.001; -0.1..0.1; positive required for uniform/normal-depth calculation. | |
| discharge | No | Positive channel discharge, e.g. '2 m^3/s'; required for analysis/profile; '' for uniform mode. | |
| manning_n | No | Conventional Manning roughness n, e.g. 0.015; 0.005..0.2; same tabulated value for SI and imperial inputs. | |
| side_slope | No | Horizontal/vertical bank slope z, e.g. 1; positive for triangular/trapezoidal; 0 for rectangular/circular. | |
| normal_branch | No | lower or upper circular normal-depth root; lower is default; upper requires discharge above full-section capacity. | lower |
| profile_steps | No | Requested profile subdivisions, 1..500; adaptive bisection adds up to 12 levels, with 500 total step attempts; actual resolution reported. | |
| boundary_depth | No | Known profile boundary depth, e.g. '1 m'; profile only; downstream for subcritical, upstream for supercritical; '' omits. | |
| profile_length | No | Positive reach length, e.g. '100 m'; required for profile; '' omits in other modes. | |
| dynamic_viscosity | No | Fluid dynamic viscosity, e.g. '1 mPa*s'; all modes; '' requires kinematic_viscosity instead. | 1 mPa*s |
| kinematic_viscosity | No | Fluid kinematic viscosity, e.g. '1 cSt'; '' omits; supply only when dynamic_viscosity is ''. |