Skip to main content
Glama
eng-toolkit

eng-toolkit

by Lin830326

Fatigue Fracture

fatigue_fracture

Compute Mode-I stress intensity factors, critical crack sizes, and fatigue crack growth for plates and specimens using LEFM, with geometry/yield checks and Paris/Forman integration.

Instructions

Mode-I LEFM: infinite/finite plates, edge/double-edge, Newman-Raju surface tension, ASTM E399 SENB/CT factors. K, critical crack, Irwin zones and size screen; Paris/Forman growth with adaptive integration and threshold. Geometry/yield limits enforced; no retardation or closure model.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "fatigue_fracture"
  }
}

Input Schema

NameRequiredDescriptionDefault
loadNoMaximum applied force P, e.g. '10 kN'; SENB/CT only, conflicts with load_range; '' omits.
modeNoevaluate, critical or growth; compute stress intensity, solve critical size or integrate crack growth.evaluate
spanNoSENB support span S, e.g. '400 mm'; requires S/W=4, unused by other geometries; '' omits.
widthNoFull plate width W or specimen width, e.g. '100 mm'; all geometries except infinite require it; '' omits.
stressNoRemote maximum tensile stress, e.g. '100 MPa'; plate geometries, conflicts with stress_range; '' omits.
geometryNoinfinite, center_secant, center_tada, edge_small, edge, double_edge, surface, senb or ct; see geometry limits in docs.infinite
growth_cNoParis/Forman C with composite units, e.g. '1e-12 m/cycle/(MPa*m^0.5)^3'; growth only; see Forman units.
growth_mNoParis/Forman power m, dimensionless .5..8; must agree with the composite units of C.
thicknessNoPlate/specimen thickness B or t, e.g. '10 mm'; surface/SENB/CT require it, others use for size screen; '' omits.
thresholdNoNo-growth Delta_K threshold, e.g. '4 MPa*m^0.5'; growth only; '' means zero threshold.
toughnessNoMode-I toughness Kc or KIc, e.g. '50 MPa*m^0.5'; required critical/Forman, optional evaluate/Paris; '' omits.
crack_sizeNoInitial crack depth a or central half-length, e.g. '2 mm'; required in evaluate/growth, optional critical; '' omits.
growth_lawNoparis or forman; Forman requires Kc and its own dimensionally different coefficient C.paris
load_rangeNoForce range Delta_P, e.g. '5 kN'; growth SENB/CT only, max=range/(1-R); '' omits.
load_ratioNoGrowth stress ratio R=Kmin/Kmax, dimensionless 0..0.95, default 0; compressive cycles are outside scope.
final_crackNoGrowth end limit a_f, e.g. '10 mm'; '' uses critical size, explicit limit is capped by Kc instability.
stress_rangeNoRemote stress range Delta_sigma, e.g. '50 MPa'; growth plates only, max=range/(1-R); '' omits.
table_pointsNoGrowth CSV stations, 2..101, default 31; log-spaced crack lengths, cumulative cycles.
surface_pointNodeepest or surface point for Newman-Raju; both K values are reported, selected point controls growth.deepest
yield_strengthNoYield stress for LEFM screens, e.g. '400 MPa'; optional, peak net-section stress above .8 yield is refused; '' omits.
surface_half_lengthNoSurface half-length c, e.g. '5 mm'; surface only, paired with initial a; growth holds a/c fixed; '' omits.
integration_toleranceNoRelative life tolerance for integration and critical endpoint, 1e-10..1e-3, default 1e-7; cap 50000 evaluations.

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.0.1

TDQS

B3.1/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description carries the full burden, and it does disclose meaningful behavior: geometry/yield limits are enforced, integration is adaptive, and retardation/closure are explicitly out of scope. It does not describe failure modes, unit-handling behavior, or what the response contains, leaving real gaps for a 22-parameter tool.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness3/5

Is the description appropriately sized, front-loaded, and free of redundancy?

It is short and front-loaded with capability keywords, but it is telegraphic and jargon-dense ('Newman-Raju surface tension', 'Irwin zones and size screen'), which reads more like a feature tag list than prose an agent can parse quickly. Every phrase is on-topic, so nothing is wasted, but clarity suffers.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 22-parameter fracture tool with no annotations and no output schema, the description covers the analytical scope but not enough operational detail. It never explains what the tool returns (K values, life tables, size screens) beyond naming them, so an agent must infer outputs from the schema alone.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, so the schema already explains every parameter including defaults, ranges and conflicts. The description adds only thematic context (Newman-Raju, ASTM E399 factors) that frames the geometry enum. Baseline 3 is appropriate since the schema does the heavy lifting.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names a specific domain (Mode-I LEFM) and enumerates concrete capabilities: K computation, critical crack size, Irwin zones, Paris/Forman growth. That is clearly distinct from the S-N and strain-life siblings. It stops short of an explicit 'use this instead of fatigue_sn' statement, so it is clear but not fully sibling-differentiated.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines2/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

There is no explicit when-to-use guidance: nothing tells the agent to pick this over fatigue_sn, fatigue_strain_life or fatigue_material, and no prerequisite or exclusion conditions are stated. The mode enum (evaluate/critical/growth) is documented in the schema, not routed here. Only scope limits ('no retardation or closure model') hint at applicability.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server