Electric Induction Motor

electric_induction_motor

Calculate three-phase induction motor steady-state performance with exact T-circuit, Thevenin torque, stable shaft-load solving, V/f scaling, and CSV output.

Instructions

Chapman/Fitzgerald three-phase induction motor: exact T circuit, Thevenin torque, stable shaft-load root, V/f and CSV. Linear unsaturated steady state; assumed nameplate fit is nonunique.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "electric_induction_motor"
  }
}

Input Schema

NameRequiredDescriptionDefault
r1NoStator resistance per phase, e.g. '0.641 ohm'; required in equivalent mode.
r2NoStator-referred rotor resistance per phase before its multiplier, e.g. '0.332 ohm'.
rcNoOptional shunt core-loss resistance per phase, e.g. '240 ohm'; omission means zero core loss.
x1NoStator leakage reactance per phase at base frequency, e.g. '1.106 ohm'.
x2NoStator-referred rotor leakage reactance at base frequency, e.g. '0.464 ohm'.
xmNoMagnetizing reactance per phase at base frequency, e.g. '26.3 ohm'.
modeNoUse equivalent for supplied per-phase parameters, or nameplate for an assumed one-point circuit fit.equivalent
slipNoOperating slip in (0,1); zero selects speed, load torque, nameplate slip or default 0.05.
polesNoEven magnetic pole count from 2 through 200.
speedNoOperating speed or nameplate speed at base frequency, e.g. '1755 rpm' or '183.78 rad/s'.
frequencyNoOperating electrical frequency, e.g. '60 Hz'; supported range 0.1 to 10000 Hz.60 Hz
connectionNoWinding connection, wye or delta; circuit impedances are per winding phase.wye
stray_lossNoConstant stray load loss, e.g. '120 W'; default assumes zero loss.0 W
load_torqueNoPositive shaft load, e.g. '70 N*m'; solves the stable motoring branch including fixed losses.
curve_pointsNoNumber of evenly spaced slip samples in the CSV curve, including 0 and 1; from 3 to 201.
line_currentNoRequired nameplate RMS line current, e.g. '20 A'; unused in equivalent mode.
line_voltageNoRMS line-to-line supply, e.g. '460 V'; base voltage when base_frequency is supplied.
output_powerNoRequired nameplate shaft output power, e.g. '7.5 kW' or '10 hp'.
power_factorNoRequired nameplate lagging power factor in (0,1); zero means unspecified.
base_frequencyNoBase electrical frequency, e.g. '60 Hz'; V/f voltage scales below base and is capped above base.
mechanical_lossNoConstant friction and windage loss, e.g. '300 W'; default assumes zero loss.0 W
rotor_resistance_multiplierNoMultiplier on stator-referred rotor resistance, from 0.01 to 100.
magnetizing_current_fractionNoNameplate fit assumes Vphase/Xm equals this fraction of nameplate phase current, from 0.01 to 0.9.

Output Schema

NameRequiredDescriptionDefault
okYes
dataNoNon-quantity payload (reports, listings)
errorNo
valueNoPrimary quantity result
valuesNoAll named quantity results (includes the primary)
warningsNo
artifactsNo
provenanceYesWhat produced the result and from which inputs.
review_statusNounreviewed

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.0.1

TDQS

A3.6/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description carries the full behavioral burden. It discloses important assumptions: linear unsaturated steady state, nonunique nameplate fit, and solving the stable shaft-load branch. It does not explicitly say the tool is a pure calculation with no side effects, but for a numerical engineering tool this is strong disclosure.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The description is two dense sentences with no filler and is front-loaded with the domain and computational methods. Specialist abbreviations like T circuit, V/f, and CSV are appropriate for the engineering audience and do not create wasteful length.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

This is a complex 23-parameter tool, but the schema is fully described and an output schema exists, reducing what the description must cover. The description supplies core model assumptions and limitations, yet it does not explain mode selection or default parameter behavior; the schema compensates but leaves clear contextual gaps.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100% and an output schema exists, so the input schema already documents all 23 parameters thoroughly. The description adds no parameter-specific meaning beyond referencing V/f and CSV, so the baseline of 3 is appropriate.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names a specific motor type and analysis techniques: three-phase induction motor, exact T circuit, Thevenin torque, stable shaft-load root, V/f and CSV. It distinguishes itself from sibling motor tools by motor type and modeling approach, though it never uses a plain verb like 'calculate' or 'analyze'.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

No explicit when-to-use or when-not-to-use guidance is given, and there is no routing to alternatives such as electric_pm_dc_motor or electric_drive_sizing. Usage is implied by the domain and by the mention of equivalent versus nameplate modes, but an agent must infer the selection context.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server