Mech Bolt Check
mech_bolt_checkCheck a metric bolt in tension: calculate tensile stress area, proof load, torque-preload relation, and proof-load utilization, optionally with external axial load; enter torque or preload.
Instructions
Check a metric bolt in tension: tensile stress area, proof load, the torque <-> preload relation T = KFd, and utilization against the proof load (optionally with an external axial load). Give EXACTLY ONE of 'torque' (tightening torque -> preload) or 'preload' (-> required torque). Tension only: shear, bending, fatigue and thread stripping are not checked.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"diameter": "<diameter>"
},
"name": "mech_bolt_check"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| pitch | No | Thread pitch with unit, e.g. '1.5 mm' (or '1.25 mm' for fine). Empty = the ISO coarse pitch of a standard size M1.6..M64. | |
| torque | No | Tightening torque, e.g. '40 N*m' or '30 lbf*ft'. Give this OR preload, not both. | |
| preload | No | Target bolt preload (axial force), e.g. '20 kN'. Give this OR torque, not both. | |
| diameter | Yes | Nominal (major) thread diameter with unit, e.g. '10 mm' for M10 | |
| load_share | No | Fraction C (0 to 1) of the external load that the bolt carries; 1.0 = all of it (conservative). | |
| nut_factor | No | Nut (torque) factor K in T = K*F*d, 0.05 to 1.0. About 0.2 for plain dry steel; lubricated is lower. | |
| unit_system | No | Unit system of the results: 'metric' (kN, N*m, mm, MPa) or 'imperial' (lbf, lbf*ft, inch, ksi) | metric |
| external_load | No | Optional external axial tension on the joint, e.g. '8 kN'. Empty = none. | |
| proof_strength | No | Proof stress Sp of the bolt material, e.g. '580 MPa' (from the standard or the supplier). Empty = estimated as 0.9 x the nominal yield strength of the class. | |
| property_class | No | ISO 898-1 property class: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 9.8, 10.9 or 12.9 | 8.8 |
Output Schema
| Name | Required | Description | Default |
|---|---|---|---|
| ok | Yes | ||
| data | No | Non-quantity payload (reports, listings) | |
| error | No | ||
| value | No | Primary quantity result | |
| values | No | All named quantity results (includes the primary) | |
| warnings | No | ||
| artifacts | No | ||
| provenance | Yes | What produced the result and from which inputs. | |
| review_status | No | unreviewed |