mech_bolt_check

Check a metric bolt in tension: calculate tensile stress area, proof load, torque-preload relation, and proof-load utilization, optionally with external axial load; enter torque or preload.

Instructions

Check a metric bolt in tension: tensile stress area, proof load, the torque <-> preload relation T = KFd, and utilization against the proof load (optionally with an external axial load). Give EXACTLY ONE of 'torque' (tightening torque -> preload) or 'preload' (-> required torque). Tension only: shear, bending, fatigue and thread stripping are not checked.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "diameter": "<diameter>"
    },
    "name": "mech_bolt_check"
  }
}

Input Schema

NameRequiredDescriptionDefault
pitchNoThread pitch with unit, e.g. '1.5 mm' (or '1.25 mm' for fine). Empty = the ISO coarse pitch of a standard size M1.6..M64.
torqueNoTightening torque, e.g. '40 N*m' or '30 lbf*ft'. Give this OR preload, not both.
preloadNoTarget bolt preload (axial force), e.g. '20 kN'. Give this OR torque, not both.
diameterYesNominal (major) thread diameter with unit, e.g. '10 mm' for M10
load_shareNoFraction C (0 to 1) of the external load that the bolt carries; 1.0 = all of it (conservative).
nut_factorNoNut (torque) factor K in T = K*F*d, 0.05 to 1.0. About 0.2 for plain dry steel; lubricated is lower.
unit_systemNoUnit system of the results: 'metric' (kN, N*m, mm, MPa) or 'imperial' (lbf, lbf*ft, inch, ksi)metric
external_loadNoOptional external axial tension on the joint, e.g. '8 kN'. Empty = none.
proof_strengthNoProof stress Sp of the bolt material, e.g. '580 MPa' (from the standard or the supplier). Empty = estimated as 0.9 x the nominal yield strength of the class.
property_classNoISO 898-1 property class: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 9.8, 10.9 or 12.98.8

Output Schema

NameRequiredDescriptionDefault
okYes
dataNoNon-quantity payload (reports, listings)
errorNo
valueNoPrimary quantity result
valuesNoAll named quantity results (includes the primary)
warningsNo
artifactsNo
provenanceYesWhat produced the result and from which inputs.
review_statusNounreviewed

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.0.1

TDQS

A4.2/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

No annotations are supplied, so the description carries the full behavioral burden, and it does disclose the important limits: the calculation is tension-only and explicitly excludes shear, bending, fatigue and thread stripping, plus the mutual exclusivity of torque and preload. It does not discuss what happens if both or neither are given, or how the proof-strength default is chosen, which are the remaining gaps for an unannotated tool.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness5/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Three sentences, front-loaded with the purpose and the computed quantities, then the input constraint, then the scope exclusion. Every sentence carries information an agent needs and none is redundant padding.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

An output schema exists, so return values need not be explained, and the description covers purpose, inputs constraints and validity limits for a ten-parameter calculation. The only shortfall is the absence of a note on what happens with conflicting or missing torque/preload inputs, which matters for correct invocation.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, so all ten parameters are already documented with units, defaults and ranges in the schema. The description adds little parameter-level meaning beyond restating the torque/preload exclusivity rule and the K factor relation already present in the schema text. The baseline of 3 is appropriate when the schema does the heavy lifting.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description opens with a specific verb and resource ('Check a metric bolt in tension') and then enumerates exactly what is computed: tensile stress area, proof load, the T = K*F*d torque-preload relation, and utilization against proof load. That is far more specific than the title, and the tension-only scope distinguishes it from any sibling that might analyze other failure modes.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

It gives a clear usage rule -- supply EXACTLY ONE of 'torque' or 'preload' -- and states the boundary of the analysis ('Tension only: shear, bending, fatigue and thread stripping are not checked'), which tells an agent when this tool is not the right choice. It does not name an alternative tool, but the listed siblings cover different components (beams, bearings, springs), so the omission costs little.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server