Skip to main content
Glama

Test a webhook

myio_webhook_test

Fires a selected webhook slot (1–8) once without the gap brake and reports the HTTP result from the trace, letting you test webhook delivery on a myIO controller.

Instructions

Fire webhook slot 1..8 (as loaded from flows.jsn hooks[]) once, without the gap brake, and report the HTTP result from the trace. GIGA/Opta 4.4.1+. Editor/admin level.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "slot": "<slot>"
    },
    "name": "myio_webhook_test"
  }
}

Input Schema

NameRequiredDescriptionDefault
slotYes
serverNocontroller name (default Ground floor)

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv1.6.2

TDQS

A3.9/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare non-read-only, open-world, non-idempotent, non-destructive. The description adds real value beyond that: it fires exactly once, bypasses the gap brake, and returns the HTTP result from the trace, plus the firmware and privilege requirements. It does not describe failure modes or side effects on the flow itself.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness5/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Two dense sentences with the action and scope front-loaded, followed by version and privilege constraints. No filler or redundancy.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a two-parameter action tool with no output schema, the description covers what it does, the return (HTTP result from trace), and access requirements. Minor gaps remain around what happens to the flow state or what a failed trace looks like.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 50%: slot has only min/max bounds and server has a description. The description compensates by explaining that slot indexes into hooks[] loaded from flows.jsn, which the schema does not convey. The server parameter is left to the schema, which is acceptable.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb and resource: fire webhook slot 1..8 once and report the HTTP result. The scope (single slot, one-shot, no gap brake) is concrete enough that an agent knows exactly what the call does, though it does not name a sibling tool to contrast with.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Provides prerequisites (GIGA/Opta 4.4.1+, editor/admin level) which help decide whether the call is permitted, but gives no explicit when-to-use versus when-not guidance or alternatives such as myio_flow_trace for inspecting flows.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server

Other Tools