Skip to main content
Glama

Configure DMX

myio_dmx_set
Destructive

Configure DMX fixtures on a myIO controller: add or delete fixtures, set addresses and types, bind channels, run tests and blackout panels. Saves changes automatically.

Instructions

DMX fixtures (Opta 4.9+; saved automatically). action: add (panel, address 1..512, type 0 dimmer / 1 RGB / 2 RGBW / 3 generic), delete (fixture), address (fixture, address), type (fixture, type), channels (fixture, count 1..16 - generic only), bind (fixture, channel 1.., pca_id 2001.. or 0), auto_bind, pool (lo, hi), test (fixture: full on for 1.5 s - state), blackout (panel: all 512 slots to 0 - state), panel_config (panel, field 0..5, value). Editor/admin level.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "action": "<action>"
    },
    "name": "myio_dmx_set"
  }
}

Input Schema

NameRequiredDescriptionDefault
hiNo
loNo
typeNo
countNo
fieldNo
panelNo
valueNo
actionYes
pca_idNo
serverNocontroller name (default Ground floor)
addressNo
channelNo
fixtureNo

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv1.6.2

TDQS

A3.7/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Beyond the annotations (destructive=true, non-idempotent), the description discloses that changes are saved automatically, that test drives a fixture full-on for 1.5 s, that blackout forces all 512 slots to 0, and that editor/admin privileges are required. It does not spell out the consequences of delete (whether fixture addressing/channels are orphaned) or whether operations can be undone, which is the main remaining gap for a destructive tool.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The content is dense but nearly every clause carries information, and the resource plus persistence note is front-loaded before the action breakdown. The telegraphic parenthetical style ('panel_config (panel, field 0..5, value)') is compact but borders on cryptic for a first-time reader.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 13-parameter destructive configuration tool with no output schema, the description covers the action space and key constraints but omits return behavior, the meaning of server/field/pool, and the state consequences of delete and bind. It is adequate to start calling the tool, but an agent would still guess on several parameters.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

With schema description coverage at 8% across 13 parameters, the description carries almost the whole burden and does so well: it maps parameters to each action and explains ranges and enum meanings (address 1..512, type 0 dimmer/1 RGB/2 RGBW/3 generic, count 1..16 generic only, pca_id 2001.. or 0, field 0..5). Gaps remain for the 'server' parameter, the meaning of the six 'field' values, and what 'pool (lo, hi)' actually controls.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names the resource (DMX fixtures) and enumerates the concrete operations available through the action parameter (add, delete, address, bind, blackout, panel_config, etc.), so an agent can tell this is the DMX bus configuration writer. It does not explicitly contrast itself with the read-side sibling myio_dmx or with the other myio_*_set bus tools, leaving that differentiation to the name alone.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

The action list implicitly tells the agent which operation to pick for a given intent, and 'Editor/admin level' plus 'Opta 4.9+' gives a permission and firmware precondition. There is no explicit when-not guidance, no mention of when to use myio_dmx to inspect state first, and no statement about ordering or side effects between actions.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.