Skip to main content
Glama

Edit the KNX table

myio_knx_set
DestructiveIdempotent

Edit Ext-KNX group-address table rows on a selected panel, commit saved changes, and manage the ETS tunnel connection for KNX configuration.

Instructions

Edit the Ext-KNX group-address table (the panel stores it; save=true (default) commits with KnxSave). panel = select another Ext-KNX panel first. rows: [{row 0..47, ga "main/middle/sub" ("" deletes the row), dir 0 none / 1 IN / 2 OUT / 3 SENSOR, dpt 1 bool / 2 percent / 3 float, local 0..15 (panel channel), target usens (SENSOR rows), invert, init_read (desired values), name (max 20, saved at once, 4.15+)}]. tunnel = enable/disable the ETS interface (4.14+), drop_tunnel=true closes the active ETS connection. Editor/admin level.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "myio_knx_set"
  }
}

Input Schema

NameRequiredDescriptionDefault
rowsNo
saveNo
panelNo
serverNocontroller name (default Ground floor)
tunnelNo
drop_tunnelNo

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv1.6.2

TDQS

A3.9/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Adds substantial context beyond the annotations: an empty ga string deletes a row, save defaults to true and commits via KnxSave, drop_tunnel=true tears down an active ETS connection, and names are persisted immediately on 4.15+. The destructive surface is therefore spelled out concretely rather than only flagged by destructiveHint=true. It remains slightly vague about what a save=false edit leaves behind.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness3/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Purpose is front-loaded, but the remainder is a single run-on block of nested parentheticals that is hard to scan for a specific field. Nearly every clause adds real information, yet the structure could be far more readable as a short list.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a six-parameter destructive setter with no output schema and low schema coverage, the description supplies field semantics, default behavior, firmware gates, and authorization level. Gaps are minor: no explicit statement of what a non-committed edit does to live state or how invalid ga strings are rejected.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters5/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is only 17%, so the description must carry the load, and it does: it explains the ga path format and deletion behavior, the dir codes 0/1/2/3, dpt codes 1/2/3, local range 0..15, target for SENSOR rows, init_read, invert, and the 20-character name limit. Almost every parameter gets meaning the raw schema lacks; only 'server' is left to the schema's own default note.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb and resource: edit the Ext-KNX group-address table, and notes the panel stores it, which tells an agent this is a mutation of device-held configuration. It does not explicitly contrast with the sibling myio_knx, so the read/write split must be inferred from the name alone.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Gives a prerequisite ('panel = select another Ext-KNX panel first') and an access requirement ('Editor/admin level'), plus the commit semantics of save=true. It never says when not to use this tool or whether a read-oriented sibling should be consulted before editing, leaving usage context implied.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.