List myIO outputs
myio_list_devicesLists myIO relays, FET/PWM and PCA channels, and groups with IDs, names, live state, levels, roles, timers, and members for use with control tools. Set include_unnamed to show unnamed elements.
Instructions
List outputs with id, name, live state and level: relays (1..RQ), FET/PWM channels (101..116, only on old hardware), PCA dimmer channels (2001..2000+PCAQ), groups (501..). Shows roles in braces: thermostat / sun-controlled / mixer / shutter-up / shutter-down / joiner / rgb: / group:, thermostat thresholds, running timers and group members. By default only NAMED elements are listed (unnamed ones are counted); set include_unnamed=true to see all. Use the ids with the control tools.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "myio_list_devices"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| type | No | only this type | |
| server | No | controller name (default Ground floor) | |
| include_unnamed | No | also list elements without a name (default false) |