Modbus RTU master

myio_modbus
Read-onlyIdempotent

Retrieve Modbus RTU bus settings, poll blocks, decoded live values, writer slots, and raw request or address-scan results for a specified myIO panel; editor/admin access required.

Instructions

Ext-RS485 Modbus RTU master on an Opta (4.16+): per panel the bus settings, the poll blocks (slave, function, start register, count, period), the fields decoded from them (type, byte order, scale, target universal sensor) with live values, the writer slots (myIO relay/PCA -> Modbus register), and raw-request / address-scan results. Editor/admin level.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "myio_modbus"
  }
}

Input Schema

NameRequiredDescriptionDefault
panelNo
serverNocontroller name (default Ground floor)

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv1.6.2

TDQS

B3.2/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare readOnly, idempotent, non-destructive, and closed-world, so the safety profile is covered; the description's real contribution is the 'Editor/admin level' permission requirement and the firmware floor (4.16+). However, it says nothing about response volume despite aggregating poll blocks, live decoded values, writer slots, and scan results into a single call. Firmware compatibility and auth are useful additions, but the omission of size/pagination behavior is a meaningful gap for an aggregate read.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

One dense sentence, front-loaded with the resource and then the contents in the order an agent would encounter them. The nested parentheticals make it slightly run-on, but no clause is filler and nothing is buried at the end.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

With no output schema, the description does the work of telling the agent what sections come back, which is the crucial missing piece for this tool, and annotations cover the safety profile. What remains thin is the parameter layer (panel vs server) and any notion of response size. For a complex aggregate read, that is close to complete but not fully self-sufficient.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 50%: 'server' is documented with its default, while 'panel' is only an integer with minimum 1 and no description. The description partially compensates by framing the payload as 'per panel', which implies panel scopes the returned configuration, but it never states that relationship explicitly or explains server's role in selecting the controller. This is the baseline 3 — marginal added meaning over the schema.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names a specific resource — the Ext-RS485 Modbus RTU master on an Opta (4.16+) — and enumerates exactly what is reported: bus settings, poll blocks, decoded fields, writer slots, and raw-request/address-scan results. That is far more specific than a vague purpose. It loses a point because there is no explicit verb (read/return) and no differentiation from the sibling myio_modbus_set, leaving the read-only intent to be inferred from the annotations.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines2/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

No when-to-use or when-not-to-use guidance is given, and the obvious read/write pairing with myio_modbus_set is never mentioned. The only usage-adjacent statement is 'Editor/admin level', which sets a privilege precondition but does not route the agent to this tool versus alternatives. The agent must infer from readOnlyHint that this is the inspection path.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Deploy Server

Other Tools