Describes the environment variables required to run the server.

NameRequiredDescriptionDefault
MYIO_NAMENoLabel used in replies (default: the host).
MYIO_STDIONo0 or 1 to force stdio on or off. By default stdio runs when started under an MCP client; a terminal start serves only HTTP.
MYIO_WRITENoWrite level: state (outputs, thermostat targets, usens, run flows / scripts, SG mode), config (default; also names, timers, scenes, structures, input/output configuration, thermostat sensor binding, Flow / script files, integration settings), admin (also users, permissions, system files, network, Cloud keys, restart / OTA).
MYIO_SERVERSNoSeveral controllers as a JSON array, e.g. [{"name":"Ground floor","url":"http://192.168.1.178","username":"admin","password":"..."}, ...]. Overrides MYIO_BASE_URL, MYIO_USERNAME and MYIO_PASSWORD; tools take server: "<name>".
MYIO_BASE_URLNoController URL, e.g. http://192.168.1.178 (port 80 by default).
MYIO_PASSWORDNoHTTP Basic auth password for the myIO user.
MYIO_TOOLSETSNoTool groups to load (core, legacy, house, config, automation, diag, integrations, expanders), default all. Example: house,automation or all,-legacy,-expanders.
MYIO_USERNAMENoHTTP Basic auth user name. The account's permission level limits what the tools can do.
MYIO_HTTP_HOSTNoOptional bind address for the Streamable HTTP transport. Defaults to 127.0.0.1; any other address requires MYIO_HTTP_TOKEN (minimum 16 characters) or the server refuses to start.
MYIO_HTTP_PORTNoOptional port for the Streamable HTTP transport. When set, the server also answers MCP over Streamable HTTP at /mcp.
MYIO_HTTP_TOKENNoBearer token for the Streamable HTTP transport. Every request needs Authorization: Bearer <token>.
MYIO_MIN_GAP_MSNoMinimum pause between two requests to one controller in milliseconds, default 150. A Due refuses request bursts.
MYIO_TIMEOUT_MSNoHTTP timeout in milliseconds, default 10000.
MYIO_INSECURE_PARSERNo0 enables the strict Node HTTP parser. The default is lenient, because the firmware writes its headers by hand.

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

This server publishes no instructions, or was last inspected before Glama recorded them.

Capabilities

Server capabilities have not been inspected yet.