Skip to main content
Glama

myIO MCP Server

Talk to your home. myIO MCP connects AI assistants such as Claude to a myIO smart home controller, so you can ask the house in plain words how warm the children's room is, what happened today, or to lower the blinds.

myIO is a central home controller developed in Hungary by myIO Smart Home Zrt. It sits on a DIN rail in the distribution cabinet and runs heating and cooling, lighting, blinds, gates and energy in one system, on its own, without the internet. This is a free, open-source Model Context Protocol (MCP) server for it: it runs on your own computer and reaches the controller over your home network, through its HTTP API.

Example

A real conversation in Claude Desktop, translated from Hungarian:

You: How warm is it in the house right now, room by room?

Claude (used myIO-MCP): Right now (20:02), according to the controller:

Room

Temperature

Bedroom

23.6 °C

Bedroom bathroom

23.3 °C

Study

26.0 °C

It is 5.3 °C outside, and the heating flow water is at 32.3 °C. The study is noticeably warmer than the others. Only the upstairs myIO controller is reachable, so I have no data on the ground-floor rooms.

You: Switch on the study lamp and lower the blinds upstairs.

Claude (used myIO-MCP): The study lamp is on, and all 9 upstairs blinds are going down: bedroom (terrace door, east, south), study, walk-in closet, guest bedroom, bathroom, staircase and guest bathroom.

One thing worth knowing: your own "Upstairs blinds DOWN" group does not include the study blind, and there is also a "Study blind down lock" switch. It is off right now, so I lowered the study blind too. If it was left out of the group on purpose, tell me and I'll raise it again.

Related MCP server: Enhanced Home Assistant MCP

Quick start (Claude Desktop)

  1. Download myio-mcp.mcpb.

  2. Open it with a double click (or in Claude Desktop: Settings → Extensions).

  3. Enter the controller's address (e.g. http://192.168.1.178), a user name and the password. Then ask.

Create a separate myIO user for the assistant, and choose how far it may go: switch only (state), change settings too (config, the default) or everything (admin). Claude Code and other MCP clients: see Configuration.

Works with every myIO controller: V3 (Arduino Due, firmware 3.12), V4 GIGA and V4 Opta (firmware 4.x). Features that only exist on V4 answer with a clear error on a V3. More: Talk to your home · Downloads · API reference (Hungarian)

Privacy: the MCP server runs locally, but the AI assistant runs on its provider's servers. Your questions, and what it reads to answer them (e.g. temperatures, output names), reach the provider.

Status (1.6.1, 2026-11-13)

1.6.1: myio_system restarts and updates a Due (3.12+) over the web too - the MYIO_NEW.BIN package is checked against the controller's chip ID before upload, and the answer says whether it was installed, rejected or cannot be installed (no device key).

Rounds 0-5 of the plan: the February 2026 server fixed, put on tests, extended with the house entities, the configuration layer, automation (Flow rules, myIO Script programs), diagnostics / logs / files, every integration and RS485 expander - and in round 5 the MCP layer: resources, prompts, toolsets, consistent annotations and an optional Streamable HTTP transport.

  • native node:http client (no more curl), one request at a time per controller, Connection: close

  • correct value scales: temperature ×100, humidity ×10, SDM voltage/current ×10, SDM power in W, PCA/FET level raw 0..255

  • every control tool reads the state back and reports what the controller actually did (a command the account has no permission for is silently dropped by the firmware)

  • several controllers in one server (MYIO_SERVERS), every tool takes a server name

  • version gate: V3 (Due 3.12) and V4 (GIGA/Opta 4.x) both supported, 4.x-only features answer with a clear error on a Due

  • entities modelled like the myIO app / Homey / Home Assistant integration: thermostat zones, shutters (protection pairs), RGB groups, wall inputs, universal sensors

  • configuration layer: globals, names, output/input configuration, protection pairs / joiners / groups, scenes, timers, users and permissions - toggle-type settings are read first and only sent when they must change

  • automation: Flow rules described in plain words with element names, validated against the firmware's card rules BEFORE upload (the firmware silently disables a rule with a bad card), saved + reloaded + read back; scripts written, compiled on the controller, compile errors returned with the offending source line; the complete script language reference is a tool (myio_reference)

  • diagnostics: health snapshot (resets, loop stalls, RAM, sockets, WiFi, NTP on a Due), Prometheus metrics, daily logs with level / text / time filters, file manager on internal flash and SD card (system files need MYIO_WRITE=admin)

  • integrations: Shelly, myIO Link, MQTT, myIO Cloud, SG-Ready, alarm panel (SIA), MIA, LED strips, network, restart / web OTA; Opta expanders: failsafe / AUX / 1-Wire, KNX (table, names, ETS interface, device programming), DALI, DMX, Modbus RTU. Toggle-type settings are always given as desired values; passwords, keys and tokens are never returned; a value containing & is refused (the firmware cannot receive it)

  • write level (MYIO_WRITE = state | config | admin) limits what the AI may change

  • MCP layer: resources (myio://<controller>/state ...), four prompts in Hungarian and English that read the controller first, toolsets (MYIO_TOOLSETS) to save context, annotations that follow one rule set, Streamable HTTP for other LAN clients (bearer token)

  • zod input schemas, mock controller + end-to-end tests (npm test, 72 tests), restoring live tests for a bench controller

Tools (102)

Tool

Toolset

What it does

myio_servers

core

the configured controllers with a live check (version, name, permission level)

myio_info

core

serial, firmware version, board, element counts (RQ/SQ/PCAQ/SENQ), permission level, feature flags, expanders, storage health

myio_find

core

name search (accent- and case-insensitive) across outputs, groups, sensors, inputs, universal sensors

myio_list_devices

core

outputs with id, name, live state/level, roles (thermostat, shutter-up/down, rgb:, group: ...), timers, members

myio_read_sensors

core

temperatures (°C), humidity (%), pulse meter, SDM630 power/voltage/current, 4.x universal sensors

myio_get_status

core

any raw JSON endpoint (sens_out.json, sens_IO.json, info.json, 4.x: usensor.json, sysdiag.json, ...)

myio_output

core

switch or dim ANY output by id: action on / off / toggle / level (level 0..255 or percent)

myio_relay_on / _off / _toggle

legacy

relay 1..RQ

myio_pca_on / _off / _toggle / myio_pca_set

legacy

PCA dimmer channel 2001..2000+PCAQ; set takes level (0..255) or percent (0..100)

myio_pwm_on / _off / _toggle / myio_pwm_set

legacy

FET/PWM output 101..116 (legacy hardware only)

myio_group_on / _off / _toggle

legacy

group 501.. (editor level needed on the controller)

myio_inputs

house

wall buttons / switches: state, name, enabled, NC (4.3.12+ / Due 3.12.7+)

myio_press_button

house

simulate a button: hit (short), press (long), release - runs the input's bound actions

myio_thermostats / myio_set_thermostat

house

sensor-controlled zones: target + band (hysteresis), heat/cool, current temperature; set target, band, raw thresholds, bind sensor

myio_shutters / myio_shutter

house

UP/DOWN pairs (protection pairs): opening / closing / stopped; open, close, stop

myio_rgb / myio_set_rgb

house

RGB groups ("RGB..." group with R/G/B channels): on/off, colour, brightness

myio_usensors / myio_set_usens

house

4.x universal sensors (KNX, Modbus, MQTT, Shelly, Script, external): read; push a value from outside

myio_send_command

core

raw key=value&key=value command string (everything in the API reference); the reply lists the outputs that changed

myio_globals / myio_set_globals

config

name, clock, time zone, location, sunrise/sunset, button timing, cooldown, sensor polling, pulse meter unit; NTP sync

myio_rename

config

name of a relay / pca / fet / group / input / thermo / humidity / usens / shelly / scene

myio_output_config / myio_set_output_config

config

auto-off timer, delay, inverted, alarm, justOn, PCA min/max, fade speed, PWM / mixer mode

myio_input_config / myio_set_input_config

config

what a wall button does: enabled, NC, hit-block, hit / press / release targets

myio_structures / myio_set_protection / myio_set_joiner / myio_set_group

config

protection pairs (shutters), joiner pairs, group members and pullUp

myio_scenes / myio_scene

config

configuration slots: list, load, save, new, delete, set_boot, rename

myio_timers / myio_set_timer / myio_delete_timer

config

timer.csv: time or sunrise/sunset ± offset, date, weekdays, event and target

myio_users / myio_user

config

accounts: list, new, delete, rename, set_password, set_rights (admin level)

myio_permissions / myio_set_permissions

config

per-element read/write and hit/press permissions of a user (map readable on 4.x)

myio_config_vars

config

any raw setting variable of the Setup page (energy manager, SDM, dew point ...)

myio_flows

automation

Flow rules (4.4+): WHEN / AND / THEN in plain words with names, live state (enabled, running, last fired), variables, webhooks; raw = flows.jsn

myio_flow_save

automation

add / replace / delete a rule, a variable or a webhook target, or replace the whole flows.jsn - validated first, then uploaded + reloaded + read back (dry_run)

myio_flow

automation

runtime: enable / disable a rule, fire its actions now, set a global variable

myio_flow_trace / myio_webhook_test

automation

what the engine did (incremental with since); fire a webhook slot and report the HTTP result

myio_scripts / myio_script_get

automation

myIO Script programs (4.10+): state, errors with line:col, timing, locals, arrays, global variables, trace; source of a slot

myio_script_save / myio_script

automation

write + compile a program (compile error with the source line); reload, run once, enable / disable (RAM or persistent), delete

myio_reference

automation

the bundled firmware documentation: complete script language, Flow card format, any API section

myio_sysdiag / myio_metrics

diag

health: uptime, last reset cause, loop stalls, RAM, M4 core, LAN/WiFi, sockets, storage, login brake; Prometheus text (4.4.1+)

myio_logs / myio_log

diag

daily CSV logs (event, consumption, SDM, temperature, humidity, usens): list; read one day with level / text / time filters and tail

myio_files / myio_file_read / myio_file_write / myio_file_op

diag

storage (internal flash q, SD card s; a Due has only the SD): list, read (text / binary), write (text / base64, make_dirs), delete / mkdir / rename / copy

myio_fm_sync

diag

internal flash -> SD configuration mirror: status, run, adopt a foreign card (4.4.3+, admin)

myio_shelly / myio_shelly_set

integrations

Shelly devices (4.1+): online, state, which myIO output / button / usens each channel is bound to; add, scan, bind, rename, auth, push

myio_link / myio_link_set

integrations

myIO Link (4.2+): other controllers polled, output and sensor links; add, scan, link, unlink

myio_mqtt / myio_mqtt_set

integrations

MQTT client (4.3+, Due 3.12.31+): broker, state, topics, HA discovery, publish masks, subscribe, external sensor bindings; save + reconnect

myio_cloud / myio_cloud_set

integrations

myIO Cloud (4.4+): state, pairing window, paired phone keys; enable, pair, revoke, delete (admin)

myio_sgready / myio_sgready_set

integrations

SG-Ready heat pump (4.4.2+, Due 3.12.9+): mode 1..4, K1/K2 outputs, utility-lock limit

myio_alarm / myio_alarm_set

integrations

SIA DC-09 alarm panel receiver (4.5.8+): partitions, troubles, counters; listeners, account, partition -> usens, simulated events

myio_mia / myio_mia_set

integrations

MIA self-learning heating (4.11+): learned zone model, window detection, preheating; features, thresholds, exclusions, reset

myio_ledstrip / myio_ledstrip_set

integrations

WS2812 strips (4.3.4+): strips, programs, effects; run/stop by event id, edit programs live

myio_network / myio_network_set

integrations

host name, LAN, WiFi STA/AP, live addresses, services per interface; change + save or apply (admin, dangerous)

myio_system

integrations

restart, web OTA upload / install (GIGA/Opta: MYIO_UPD.BIN + roll back; Due 3.12+: MYIO_NEW.BIN to the SD card, checked for the controller's chip ID before upload), admin - waits for the controller and reports the running version and the outcome

myio_expanders / myio_expander_set

expanders

Opta RS485 panels (4.5+): type, online, firmware, failsafe/standalone, AUX mode, Ext16 1-Wire

myio_knx / myio_knx_set / myio_knx_device

expanders

Ext-KNX: group-address table with names, ETS tunnelling interface, devices; edit rows + KnxSave, scan / program addresses (admin)

myio_dali / myio_dali_set

expanders

Ext-DALI (4.8.6+): endpoints, bindings, desired vs driver parameters, groups; bind, settings, groups, scan, commission (admin)

myio_dmx / myio_dmx_set

expanders

Ext-DMX (4.9+): fixtures and channel bindings; add, bind, test, blackout

myio_modbus / myio_modbus_set

expanders

Ext-RS485 Modbus RTU (4.16+): blocks, decoded fields with live values, writer slots, bus; edit tables, presets, raw request, address scan

Element ids are shared by all tools and channels: relays 1..RQ, FET 101..116, groups 501.., PCA 2001..2000+PCAQ (see API_REFERENCE.md chapter 3).

Annotations follow one rule set: read tools are readOnlyHint; a desired-value setter (on / off / level / target / name / a setting) is idempotentHint - calling it twice changes nothing more (an identical protection pair, joiner or timer is reused, not duplicated); toggles, fire / run, button presses and add / new actions are not; tools that can overwrite or delete stored configuration are destructiveHint (switching an output is a reversible state change, not destructive); a tool with several actions is annotated for its most dangerous one. myio_webhook_test is openWorldHint (it calls an outside URL).

Toolsets

The 102 tool descriptions cost context. MYIO_TOOLSETS loads only some groups (the same field is in the Claude Desktop settings):

Toolset

Tools

core (always)

myio_servers, myio_info, myio_find, myio_list_devices, myio_read_sensors, myio_get_status, myio_output, myio_send_command (8)

legacy

the per-type switches from 2026-02: myio_relay_* / myio_pca_* / myio_pwm_* / myio_group_* (14) - myio_output covers them

house

inputs, button simulation, thermostats, shutters, RGB, universal sensors (10)

config

settings, names, output / input configuration, structures, scenes, timers, users, permissions (21)

automation

Flow rules, scripts, the language / API reference (10)

diag

sysdiag, metrics, logs, files, SD mirror (9)

integrations

Shelly, Link, MQTT, Cloud, SG-Ready, alarm, MIA, LED strips, network, restart / OTA (19)

expanders

Opta RS485 expanders: Ext16, KNX, DALI, DMX, Modbus (11)

Examples: MYIO_TOOLSETS=house,automation (core + 20), MYIO_TOOLSETS=all,-legacy,-expanders (77). Empty or all = everything (default). Unknown names are reported on stderr; core cannot be switched off. The server instructions tell the model which groups are not loaded, and the prompts only mention tools that are. Resources and prompts do not depend on the toolsets.

Resources

Attachable context - the client reads them without a tool call. <controller> is the URI-safe form of the controller name (Földszint -> foldszint, Ground floor -> ground-floor; printed on stderr at start).

URI

Content

myio://<controller>/info

info.json + the feature map derived from the firmware version (JSON)

myio://<controller>/state

decoded live state in real units: outputs (level, roles, timers, thermostat thresholds), sensors, inputs, universal sensors (JSON)

myio://<controller>/flows.jsn

the Flow rule file (4.4+)

myio://{controller}/prog/{n}.txt

template: source of script slot n (4.10+)

myio://{controller}/log/{date}

template: one day of the event log, today / yesterday / YYYY-MM-DD / YYMMDD (last 256 KB)

myio://docs/index

contents of the bundled API reference with the chapter URIs

myio://docs/script / myio://docs/flow

the myIO Script language (10/G) / the Flow card format (10/D)

myio://docs/chapter/<id>

one chapter: 1 .. 13, 10-a .. 10-h (Hungarian)

myio://docs/search/{query}

template: every section whose heading contains the query (accent-insensitive)

The templates offer completion (controller names, slot numbers, the last seven days).

Prompts

Each prompt reads the controller(s) when it is requested and embeds the data, so the conversation starts with full context (every data block fails on its own: "not available: ..."). Argument language: hu (default) or en; server limits it to one controller.

Prompt

Arguments

What it collects

heating_overview

server, language

thermostat zones (target, band, current, heating), temperatures and humidity, MIA learned model and today's MIA events, SG-Ready - for every controller

why_not_switching

element (name or id), server, language

the output's state and roles, account level, output configuration, thermostat control, protection / joiner / group, timers and scene loads, bound wall buttons, Flow rules and scripts that use it, myIO Link, MQTT control, SG-Ready contacts, today's switching commands for it in the event log. An ambiguous name returns the candidates.

daily_diagnostics

server, date, language

info, sysdiag (resets, RAM, sockets, link / WiFi, NTP), clock vs this computer + time zone / DST, the event log's error and notable lines grouped, RS485 expanders, Flow and script errors - for every controller

new_flow_rule

rule (plain words), server, language

the existing rules, the named outputs and sensors with ids, the 10/D card reference; the model is told to clarify, draft, dry-run (myio_flow_save dry_run=true), explain, and save only after approval

Streamable HTTP (optional)

stdio stays the default. With MYIO_HTTP_PORT the server also answers MCP over Streamable HTTP at /mcp, for other MCP clients on the LAN:

MYIO_HTTP_PORT=8765 MYIO_HTTP_HOST=0.0.0.0 MYIO_HTTP_TOKEN=$(openssl rand -base64 24) \
MYIO_BASE_URL=http://192.168.1.178 MYIO_USERNAME=admin MYIO_PASSWORD=... node dist/index.js
# client: URL http://<this-machine>:8765/mcp, header  Authorization: Bearer <token>
  • binds to 127.0.0.1 by default; any other address needs MYIO_HTTP_TOKEN (min. 16 characters) or the server refuses to start. On loopback without a token a random one is generated and printed on stderr.

  • every request needs Authorization: Bearer <token> (compared in constant time); sessions are kept in memory (max 16, idle 30 min).

  • all sessions share the controller clients, so the per-controller request queue (and MYIO_MIN_GAP_MS) still protects the firmware.

  • started from a terminal it serves only HTTP; under an MCP client (stdin is a pipe) stdio runs too. MYIO_STDIO=0|1 forces it.

  • plain HTTP: use it inside the home network or behind a TLS reverse proxy / VPN, not on the open internet. On macOS the application firewall may ask to allow incoming connections for node.

Configuration

Environment variables (the Claude Desktop extension asks for them as user config):

Variable

Meaning

MYIO_BASE_URL

controller URL, e.g. http://192.168.1.178 (port 80 by default)

MYIO_USERNAME / MYIO_PASSWORD

HTTP Basic auth; the account's permission level limits what the tools can do

MYIO_NAME

label used in replies (default: the host)

MYIO_SERVERS

several controllers: JSON array [{"name":"Ground floor","url":"http://192.168.1.178","username":"admin","password":"..."}, ...] - overrides the three above; tools take server: "<name>"

MYIO_WRITE

write level: state (outputs, thermostat targets, usens, run flows / scripts, SG mode), config (default; also names, timers, scenes, structures, input/output configuration, thermostat sensor binding, Flow / script files, integration settings), admin (also users, permissions, system files, network, Cloud keys, restart / OTA)

MYIO_TOOLSETS

tool groups to load (see Toolsets), default all

MYIO_HTTP_PORT / MYIO_HTTP_HOST / MYIO_HTTP_TOKEN / MYIO_STDIO

optional Streamable HTTP transport (see above)

MYIO_TIMEOUT_MS

HTTP timeout, default 10000

MYIO_MIN_GAP_MS

minimum pause between two requests to one controller, default 150 (a Due refuses request bursts)

MYIO_INSECURE_PARSER

0 = strict Node HTTP parser (default lenient: the firmware writes its headers by hand)

Claude Desktop

Install myio-mcp.mcpb (Settings → Extensions) and fill in the URL, user and password. To rebuild the bundle:

npm install
npm run pack          # = sync-docs + tsc + mcpb pack . myio-mcp.mcpb

Claude Code / other MCP clients (stdio)

{
  "mcpServers": {
    "myio": {
      "command": "node",
      "args": ["/absolute/path/to/myio-mcp/dist/index.js"],
      "env": { "MYIO_BASE_URL": "http://192.168.1.178", "MYIO_USERNAME": "admin", "MYIO_PASSWORD": "..." }
    }
  }
}

Development

npm install
npm run build         # TypeScript -> dist/
npm test              # build + mock controller + end-to-end tests over stdio (node --test)
MYIO_BASE_URL=http://192.168.1.56 MYIO_USERNAME=admin MYIO_PASSWORD=... npm run smoke   # read-only check on a real controller
node test/mock_myio.mjs --serve 8111    # standalone mock controller (MOCK_VERSION=3.12.30 for a Due-like one)
npm run sync-docs     # copy ../SD_Files/js/lang/HU/API_REFERENCE.md (the canonical reference) into the package; --check only compares
LIVE_SERVERS='[{"name":"Opta","url":"http://192.168.1.60","username":"admin","password":"..."}]' node test/live_mcp5.mjs   # resources + prompts + HTTP, read-only

Layout: src/api.ts (HTTP client + command dispatch), src/model.ts (JSON → devices/sensors, scales, version gate), src/model_auto.ts (Flow validation / description, script state, traces), src/model_diag.ts (sysdiag, logs, files), src/servers.ts (several controllers, URI slugs), src/toolsets.ts (MYIO_TOOLSETS), src/resources.ts, src/prompts.ts, src/docs.ts (the bundled reference), src/http.ts (Streamable HTTP), src/tools/common.ts (read-back, desired-toggle and command helpers), src/tools/basic.ts + house.ts + config.ts + auto.ts + diag.ts + integr.ts + bus.ts (tool families on McpServer), src/index.ts (config + transports), test/mock_myio.mjs (controller mock built from the real d_sens_out.json sample, with an in-memory file system, Flow and Script engines), test/mcp.test.mjs, test/house.test.mjs, test/config.test.mjs, test/auto.test.mjs, test/integr.test.mjs, test/mcp5.test.mjs (resources, prompts, toolsets, annotations, HTTP); test/live_write.mjs, test/live_config.mjs, test/live_auto.mjs and test/live_integr.mjs are restoring live tests for a BENCH controller only; test/live_mcp5.mjs only reads. node test/call.mjs <tool> '<json>' ... calls tools by hand.

Rules the server follows (from the API reference, chapter 12)

  1. One request at a time, Connection: close, no polling faster than 1 s - the controller has 3 listen sockets.

  2. Commands go as POST /info.json body (the GET /command: path does not URL-decode), max 1024 bytes.

  3. The command reply is an HTML/JSON acknowledgement, not the new state: read sens_out.json back.

  4. JSON keys may be missing (permission filtering): never rely on a fixed key set.

  5. Toggle-type config commands (relaysInvert=<id> ...) invert a flag - read first, send only on change.

  6. Fixed point: temperature ×100, humidity/usens/SDM U,I ×10, thresholds ×10, PCA/FET level raw 0..255.

License

MIT, see LICENSE.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      A
      quality
      D
      maintenance
      Enables control and monitoring of Plugwise smart home devices including thermostats, switches, and energy meters with automatic network discovery. Supports temperature control, energy monitoring, and multi-hub management through natural language commands.
      16
      29 npm
      2
      MIT
    • A
      license
      C
      quality
      B
      maintenance
      Integrates AI assistants with the Domoticz home automation system to monitor and control smart home devices, scenes, and variables. It enables users to manage device states, room configurations, and system logs through the Model Context Protocol.
      31
      GPL 3.0
    • A
      license
      A
      quality
      D
      maintenance
      Connects Claude and other MCP clients to myGEKKO building controllers via the official Query API, enabling natural-language queries and control of smart-home devices. It is read-only by default, with write actions available only through explicit opt-in and safety policies.