Set thermostat
myio_set_thermostatConfigure a heating or cooling thermostat zone by setting target temperature, hysteresis band, or raw ON/OFF thresholds, and optionally bind or unbind its sensor. The controller applies the change and reads the zone back.
Instructions
Change a thermostat zone: target temperature (°C, keeps the band), band / hysteresis (°C 0.1..10, keeps the middle), or the raw ON/OFF thresholds (°C). Optionally bind the sensor: sensor = 1..100 (1-Wire id), 301.. (universal sensor 300+id), 0 = unbind (editor level). Heating = ON below OFF, cooling = ON above OFF. The controller switches the output itself; the reply reads the zone back.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"id": "<id>"
},
"name": "myio_set_thermostat"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| id | Yes | relay id (1..RQ) or PCA id (2001..) of the zone | |
| on | No | ON threshold °C (raw; use with off) | |
| off | No | OFF threshold °C (raw; use with on) | |
| band | No | band / hysteresis °C (0.1..10) | |
| sensor | No | bind this sensor id (1..100 1-Wire, 301+ usens, 0 = unbind) | |
| server | No | controller name (default Ground floor) | |
| target | No | target °C (-30..100) |