The Cable Code
Server Details
Decode cables in 71 coding systems; design, rate, check, find equivalents; drums, laying, fire.
- Status
- Healthy
- Uptime
- 100.0% over the last 24 hours
- Last Tested
- Transport
- Streamable HTTP · MCP 2025-11-25
- URL
- ChatGPT
- –
- Claude
- –
TDQS
Scored across 25 tools
Most tools map to clearly distinct cable-engineering tasks, and cross-references in descriptions help guide selection. However, find_equivalents and equivalence_report both compare cross-standard cable equivalents, and check_cable overlaps with extract_datasheet when a standard is supplied, so some misselection risk remains.
All names are snake_case and generally readable. Action tools mostly use verb_noun (check_cable, design_cable, read_tender) while calculation/resource tools use noun phrases (burial_depth, conduit_fill, drum_fit), which is not perfectly uniform but is predictable enough.
25 tools is heavy for a single server and includes several specialized paid calculations. The broad cable-engineering lifecycle scope prevents it from feeling extreme, but it sits at the rubric's borderline-heavy range.
Coverage is broad: design, decoding, standards checks, equivalents, installation fills and pulls, thermal/electrical ratings, drum logistics, datasheets, tenders and specifications. Minor gaps remain around earthing/grounding and some standalone LV calculations, but core workflows have no obvious dead ends.
Available Tools
25 toolsawg_metricAWG or kcmil to mm² and back, by area and by resistanceARead-onlyInspect
AWG / kcmil against IEC 60228 mm2, both ways, by area and by maximum resistance at 20 °C, each size with its resistance and source; with k, the ICEA insulation constant in MΩ·km. Send awg or mm2, metal Cu (default) or Al. Free, no LLM. Notes: thecablecode://guide/awg_metric.
Inputs: k, awg, mm2, lang, +1 more.
burial_depthMinimum burial depth of a cable by countryARead-onlyInspect
Minimum burial cover of a power cable by country, voltage and place (open ground, road, pavement; direct or in a raceway for US and AU), from that country's rule with its source and seen level, or null with the reason. Free, no LLM. Notes: thecablecode://guide/burial_depth.
Inputs: u (required), country (required), place, method.
cable_prepCable end preparationARead-onlyInspect
End preparation of an LV, MV or HV cable for a termination or joint: cut steps with the design's depths, makers' cut-back lengths (typical), lug, accessory kinds, outdoor creepage (IEC TS 60815-3), glands and cleats. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/cable_prep.
Inputs: pdf, full, lang, spec, +4 more.
check_cableCheck a power cable against a standardARead-onlyInspect
Check a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required, found, pass / fail / not checkable and its source. Deterministic, no LLM; not a certificate or a type test. Notes: thecablecode://guide/check_cable. 2 free checks per caller per UTC day, then $0.50 USDC per check (x402).
Inputs: design, standard, designation, construction.
cold_weather_checkCold-weather laying checkARead-onlyInspect
A place's long-term mean daily minimum in a month (NASA POWER, stored) against the design's minimum laying temperature: comfortable, marginal, prewarm or unknown. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/cold_weather_check.
Inputs: lang, spec, input, items, +2 more.
commissioning_sheetCommissioning sheet (PDF)ARead-onlyInspect
The tests after installation for a design (IEC 60502-2, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with voltage, duration and source, as a PDF to record results in. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/commissioning_sheet.
Inputs: lang, spec, input, items, +2 more.
conduit_fillNEC conduit fill: the smallest trade sizeARead-onlyInspect
NEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) for a list of conductors or cables, against Table 1's fill limits, with the jam ratio; each area with its table. Free, no LLM. Notes: thecablecode://guide/conduit_fill.
Inputs: cables (required), nipple, raceway.
decode_cable_codeDecode a cable designationARead-onlyInspect
Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM. 5 free calls per caller per UTC day (with find_equivalents, overhead_conductor), then $0.10 USDC per call (x402).
Inputs: code (required), lang.
degassing_timeXLPE degassing time estimateBRead-onlyInspect
Days an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait beside it up to 46 kV. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/degassing_time.
Inputs: lang, spec, input, items, +2 more.
design_cableDesign and size a power cableARead-onlyInspect
Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence in any site language, a designation, a spec or a design: each layer with its standard and source, diameter, weight, designation, current, voltage drop and short-circuit ratings, optional files (XML, DXF, SVG, CSV, GLB, STEP, PDF). Deterministic, no LLM; nominal values. Notes: thecablecode://guide/design_cable. 2 free designs per caller per UTC day, then $0.50 USDC per design (x402).
Inputs: cpc, nec, lang, load, +8 more.
design_presetsList what the cable designer can buildARead-onlyInspect
What design_cable builds: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it, its designation, voltage, cores, section and metal; and spec_standards[], the families a spec may name in spec.standard. Takes only lang. Free, no LLM.
Inputs: lang.
drum_fitFind the cable drum a length needsARead-onlyInspect
Which cable drum (reel) a length needs (od, length), or what one drum takes (od, D, d, W): nested whole layers on 1.05 x OD under a freeboard, over KTG, Nordic K, DIN, Spanish, NEMA, Turkish, IS 10418 and makers' drums with sources, with barrel and load checks; reeling adds the NFPA 79 derating, lagging the handling block. Notes: thecablecode://guide/drum_fit. Free, outside the daily calls; deterministic, no LLM.
Inputs: od (required), D, W, d, +16 more.
drum_loadingDrum loading plan for trucks and containersARead-onlyInspect
How filled drums travel: vehicles needed by space and payload, rows, chocks, and EN 12195-1 securing (blocking, lashings), each vehicle compared, with sources. Choose the drum with drum_fit (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/drum_loading.
Inputs: full, lang, input, items.
economic_sizeEconomic size of an MV or HV designARead-onlyInspect
Economic conductor size of an MV or HV design (IEC 60287-3-2): losses and their present cost for this size and the two sizes up, and the payback, each step with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/economic_size.
Inputs: lang, spec, input, items, +2 more.
equivalence_reportIEC against NEC / UL equivalence reportARead-onlyInspect
An IEC cable in mm2 against its North American counterpart (XHHW-2, RHW-2, THHN or MV-105), value by value with sources, as lines and a report file; never a statement of interchangeability. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/equivalence_report.
Inputs: lang, spec, input, items, +2 more.
extract_datasheetRead a cable datasheet into constructionsARead-onlyInspect
Read a power cable datasheet (an https link to a PDF or page, or pasted text) into constructions: each size's voltage, cores, conductor, layers with nominal and smallest thickness, screen, armour, diameters and standards, with page and row. An LLM (Claude) reads, deciding nothing; with standard set the rules check each row. Notes: thecablecode://guide/extract_datasheet. Price (USDC, x402): a paid call from the first document: $2.00 in USDC per document, no free allowance.
Inputs: url, hint, text, standard.
find_equivalentsFind a cable's equivalents in other countriesARead-onlyInspect
The same power cable under other countries' standards (IEC 60502, HD 603, HD 620, BS, EN 50618, HD 627), rebuilt and compared layer by layer with sources: equivalent, close (the differences) or none (the reason). Deterministic, no LLM; never a statement of interchangeability. Notes: thecablecode://guide/find_equivalents. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).
Inputs: code, lang, design, country, +1 more.
fire_classLowest fire class or listing a country asks forARead-onlyInspect
The lowest fire class or listing a country asks for in a kind of building or space (DE, ES, FR, GB, IT, TR, US: escape route, high-rise, tunnel, hospital, plenum ...), the rule lines with sources and seen levels; the US NEC Article 722 listing ladders. To read a printed class use decode_cable_code. Free, no LLM. Notes: thecablecode://guide/fire_class.
Inputs: place (required), country (required), lang.
iec60287_ratingIEC 60287 rating of one MV or HV circuitARead-onlyInspect
IEC 60287 rating of one MV or HV circuit at the site sent (buried, ducts or air), each step with clause and page; optional IEC 60853 cyclic and emergency ratings, banks, troughs, crossings. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/iec60287_rating.
Inputs: lang, spec, input, items, +2 more.
mv_electricalElectrical values of an MV or HV designARead-onlyInspect
MV or HV design: capacitance, charging current, reactance, a.c. resistance (IEC 60287-1-1), dielectric loss and impulse levels (IEC 60502-2), each with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/mv_electrical.
Inputs: lang, spec, input, items, +2 more.
overhead_conductorLook up a bare overhead line conductor (EN 50182, ACSS)ARead-onlyInspect
A bare overhead line conductor (AAC, AAAC, ACSR, ACSS) by its code ("242-AL1/39-ST1A", EN 50182; "401-AL0/28-MEHST", FprEN 50540) or an EN 50182 Annex F table ("F.19"): stranding, areas, diameters, mass, strength and resistance as printed, with table and page. Deterministic, no LLM. Notes: thecablecode://guide/overhead_conductor. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).
Inputs: row, code, core, table.
pull_cableCable pull: tensions and sidewall pressureARead-onlyInspect
Pull a cable through straights and bends (conduit or rollers): tension per segment from either end, sidewall pressure per bend, jam ratio and fill, against the allowable values with sources. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/pull_cable.
Inputs: pdf, full, lang, spec, +4 more.
read_tenderRead a tender document: cables built, requirements, schedule, conflicts and gapsARead-onlyInspect
Read a tender or project document's text into its cables (built and checked by the rules), the required / offered schedule, requirements, conflicts and missing sections, with pages. An LLM (Claude) copies values, deciding nothing. Waits up to about two minutes, then answers a poll link (GET /api/v1/tender/{job}); a PDF: POST /api/v1/tender. Notes: thecablecode://guide/read_tender. Always paid: $4.00 up to 20 pages, $2.00 for each further 10 pages begun, up to 80 pages, USDC (x402).
Inputs: text (required), hint, lang.
tray_fillNEC cable tray fill and ampacityARead-onlyInspect
NEC cable tray fill (392.22) and each cable's derated ampacity (392.80), up to 2000 V and Type MV: pass or fail. A conduit: conduit_fill (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/tray_fill.
Inputs: pdf, full, lang, input, +1 more.
write_specificationWrite a cable specification and its required / offered scheduleARead-onlyInspect
Write the cable specification for a tender, one cable or a project, each as design_cable takes it, with the project's requirements: the specification in tender order (Markdown and text) and the required / offered schedule (CSV and JSON), REQUIRED filled with sources, OFFERED left for the bidder. Deterministic, no LLM; a draft to check. Notes: thecablecode://guide/write_specification. Always paid: $2.00 for the first cable, $0.50 for each further cable in the same call, up to 30, USDC (x402).
Inputs: drum, lang, spec, cables, +5 more.
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
Related MCP Connectors
Electrical single-line and multi-line diagrams: build, check (NF C 15-100, IEC 60364), draw, PDF.
Plan DC electrical systems: find components, calculate circuits, check designs and create drafts.
Engineering intelligence: site layouts, energy, calculators, official data and company checks.
Free AREI cable sizing, Synergrid C10/26 inverter check, LED strip calculator. No account.
Related MCP Servers
- AlicenseAqualityCmaintenanceEnables offline AC cable sizing and verification by evaluating current capacity, voltage drop, derating, earth-fault loop impedance, and short-circuit thermal withstand against bundled or operator-supplied reference data. It also produces calculation reports identifying performed and omitted checks.72MIT
- AlicenseAqualityBmaintenanceEnables offline, deterministic calculations for Japanese and Taiwan era conversion, rosette ribbon and paracord lengths, camping tarp guylines, booklet imposition, doujin shipping thickness, leather thread, and audio cassette side splitting.8MIT
- AlicenseNot gradedqualityDmaintenanceEnables estimation of video surveillance, structured cabling, and low-current systems projects, providing tools for cost estimation, bill of materials, commercial proposals, and camera placement recommendations.MIT
- AlicenseAqualityDmaintenanceEnables users to search generator guidance, check connector and receptacle compatibility, and calculate cord sizing based on distance and voltage drop.3MIT
Glama MCP Gateway
Add one secure layer between your agents and this server.