PlanElec Calculators
Server Details
Free AREI cable sizing, Synergrid C10/26 inverter check, LED strip calculator. No account.
- Status
- Healthy
- Uptime
- 100.0% over the last 24 hours
- Last Tested
- Transport
- Streamable HTTP · MCP 2025-11-25
- URL
- ChatGPT
- –
- Claude
- –
TDQS
Scored across 8 tools
Most tools have clearly distinct purposes, but check_inverter_c10_26 and get_inverter_datasheet overlap because the approval check also returns datasheet data. suggest_inverter_c10_26 helps resolve device names before lookup, and the two calculators and two regelwerk tools are well separated.
Every tool follows a predictable snake_case verb_noun or verb_domain pattern: calculate_led_strip, check_inverter_c10_26, get_inverter_datasheet, get_regelwerk_article, search_help_guides, search_regelwerk, size_cable_arei, suggest_inverter_c10_26. The verb choices vary naturally with the action but remain consistent and readable.
Eight tools is well scoped for a calculators plus regulatory-lookup server. Each tool covers a distinct workflow, and there is no obvious padding or redundancy.
The surface covers LED strip calculation, cable sizing, inverter homologation and datasheet lookup, AREI/RGIE search and article retrieval, and help-guide search. The main gap is that search_help_guides returns only summaries and links with no matching get_help_guide tool to retrieve the full article, unlike the regelwerk search/get pair.
Available Tools
8 toolscalculate_led_stripCalculate an LED strip: current, power supply, feed pointsARead-onlyIdempotentInspect
Calculates power, current (total and per channel), required feed points, power-supply size and the extra-low-voltage feed cable for an analogue LED strip (5/12/24/48 V DC; single colour, CCT, RGB, RGBW, RGB+CCT). Provide the strip length in metres and either a preset or the datasheet values (voltage, colour channels, watts per metre at full load). Optional: cut unit, maximum length per feed, number of feeds, power-supply reserve, feed-cable length, material and cross-section, and voltage-drop limit. Planning values from datasheet data, not a manufacturer guarantee; current-carrying capacity, heat and AREI/RGIE rules for SELV, bathrooms and outdoor areas are not checked. The response includes a shareable link that opens the calculation on planelec.be.
Inputs: lengthM (required), feeds, locale, preset, +10 more. Returns: feeds, input, powerW, source, +8 more
check_inverter_c10_26Check an inverter against Synergrid C10/26ARead-onlyIdempotentInspect
Checks whether a PV inverter, battery inverter or other power-generating unit (PGU) is on the Synergrid C10/26 list of devices homologated for connection to the Belgian grid. Returns the outcome (found, found_with_limitations, expired, not_found, brand), matching devices with homologation dates, limitations and firmware versions, and homologated alternatives when nothing matches. Where available, each match also carries a separate "datasheet" object with manufacturer datasheet values (DC voltage, MPPT data, links, source URLs, status, last verified date); these are NOT checked by Synergrid and are not part of the approval. Search by brand and model, for example "Huawei SUN2000-10KTL".
Inputs: query (required), locale, phases, smaxVa. Returns: source, matches, outcome, dataDate, +3 more
get_inverter_datasheetGet inverter datasheet dataARead-onlyIdempotentInspect
Returns manufacturer datasheet data for an inverter from the Synergrid C10/26 list: maximum DC voltage, MPPT count and range, current limits per MPPT, start voltage, maximum PV power, battery capability, optimizer architecture, links to the datasheet and installation manual, the product photo URL, source URL and page per value, status (verified = stated in the datasheet, secondary = unconfirmed) and the date last verified. These are manufacturer statements and are NOT part of the Synergrid approval; use check_inverter_c10_26 for the approval status. Look up by Synergrid reference (GLV…) or by brand and model.
Inputs: brand, model, locale, reference. Returns: note, source, datasheet
get_regelwerk_articleRead an AREI/RGIE articleARead-onlyIdempotentInspect
Returns the text of one article of Book 1 of the Belgian AREI/RGIE by its number (for example 4.2.4.3 or "AREI 7.1.4.3"), in the language of the text (Dutch, French or German; English uses the German text), with the edition, change notices of amending decrees, the titles of its sub-articles and a link to the article in the PlanElec reader. Cite the article number and edition when you pass the content on. Use search_regelwerk to find the number.
Inputs: article (required), locale, version. Returns: text, title, source, article, +4 more
search_help_guidesSearch the PlanElec help centerARead-onlyIdempotentInspect
Searches the PlanElec guides about getting started, automatic planning, document exports, AREI self-check coverage, floor plan import, symbols and circuits in the visitor’s current language. Returns up to five guides with title, summary, category and a link to the full article; the article text itself is not returned.
Inputs: query, locale. Returns: source, results
search_regelwerkSearch the Belgian AREI/RGIE regulationsARead-onlyIdempotentInspect
Searches Book 1 of the Belgian AREI/RGIE (Royal Decree on electrical installations) in the language of the text: Dutch, French or German; English uses the German text. Returns up to ten articles with number, title, an excerpt, the edition in force today and a link to the article in the PlanElec reader; the full article text is not returned, use get_regelwerk_article for it. Search by keywords or by article number such as 4.2.4.3. Results are planning aids, not an official inspection.
Inputs: query (required), limit, locale, version. Returns: source, edition, results
size_cable_areiSize a cable per AREI/RGIEARead-onlyIdempotentInspect
Calculates the required copper or aluminium cable cross-section for a residential circuit under the Belgian AREI/RGIE: design current, voltage drop per cross-section, protection check against the breaker rating and the recommended cross-section. Provide the load (A, W, kW or kVA), one-way cable length in metres, the network (1x230V, 3x230V, 3x400V) and the breaker rating; other fields use the defaults for a typical socket circuit. The response includes a shareable link that opens the same calculation on planelec.be.
Inputs: mode, cosPhi, locale, lengthM, +9 more. Returns: input, source, nextSteps, comparison, +5 more
suggest_inverter_c10_26Suggest brands or models from the Synergrid C10/26 listARead-onlyIdempotentInspect
Typeahead for the Synergrid C10/26 list: given a partial brand or model name, returns matching brands with device counts or, once a brand is recognised, its homologated models. Use this to resolve an ambiguous device name before calling check_inverter_c10_26.
Inputs: query (required), locale. Returns: brands, models, source, matchedBrand
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
Related MCP Connectors
NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
Plan Belgian electrical installations (AREI/RGIE): projects, circuits, boards. Needs PlanElec Pro.
Electrical single-line and multi-line diagrams: build, check (NF C 15-100, IEC 60364), draw, PDF.
Cable sizing, Part P, certificate checks and G98/G99 for UK electricians' AI assistants
Related MCP Servers
- AlicenseNot gradedqualityCmaintenanceNine tools for indoor climate and household energy in Germany/EU: BTU sizing for a room, portable-AC window-seal length, live heatwave outlook, appliance running costs, heating watts, dew point for safe ventilation, and balcony-storage subsidy rules. Also searches and reads 133 guides on getecoback.com; no auth, no personal data, and every answer returns its source URL.CC BY-4.0
- AlicenseAqualityCmaintenanceEnables offline AC cable sizing and verification by evaluating current capacity, voltage drop, derating, earth-fault loop impedance, and short-circuit thermal withstand against bundled or operator-supplied reference data. It also produces calculation reports identifying performed and omitted checks.72MIT

NOVTRIQ Engineeringofficial
AlicenseCqualityCmaintenance27 deterministic engineering compliance and calculation tools for the built environment (data-centre PUE and EED, EPBD, NIS2, Eurocode, UAE compliance), callable by AI agents via MCP and REST API. Free tier; every result cites the governing standard.27MIT- AlicenseAqualityDmaintenanceProvides professional-grade data center engineering calculations including cooling, power, GPU thermal optimization, UPS/battery sizing, tier classification, and commissioning workflows, compliant with ASHRAE and Uptime Institute standards.8309 npm1MIT