datacenter-mcp-server
Click on "Install Server".
Wait a few minutes for the server to deploy. Once ready, it will show a "Started" state.
In the chat, type
@followed by the MCP server name and your instructions, e.g., "@datacenter-mcp-serverCalculate cooling load for 500kW IT load in Miami with N+1 redundancy"
That's it! The server will respond to your query, and you can continue using it as needed.
Here is a step-by-step guide with screenshots.
datacenter-mcp-server
Mission-critical data center engineering tools for AI agents. 8 professional-grade calculation engines covering cooling, power, GPU thermal optimization, UPS/battery sizing, tier classification, and commissioning workflows.
Built on the Model Context Protocol (MCP) standard — works with Claude Desktop, Cursor, Windsurf, Cline, and any MCP-compatible client.
Quick Start
Claude Desktop
Add to your claude_desktop_config.json:
{
"mcpServers": {
"datacenter": {
"command": "npx",
"args": ["-y", "datacenter-mcp-server"]
}
}
}Cursor / Windsurf
Add to your MCP settings:
{
"datacenter": {
"command": "npx",
"args": ["-y", "datacenter-mcp-server"]
}
}HTTP Mode (Remote)
TRANSPORT=http PORT=3001 API_KEY=your-secret npx datacenter-mcp-serverRelated MCP server: thermal-mcp-server
Tools
dc_calculate_cooling_load
Calculate ASHRAE-compliant cooling requirements for any data center facility. Inputs include IT load, redundancy level, climate zone, altitude, and humidity targets. Returns tonnage, airflow, chilled water capacity, and energy estimates.
dc_analyze_power_redundancy
Analyze electrical distribution from utility feed through UPS, PDU, and rack-level power. Supports N, N+1, 2N, and 2N+1 redundancy configurations with efficiency and cost analysis.
dc_assess_tier_classification
Evaluate facility design against Uptime Institute Tier I-IV standards. Identifies compliance gaps and provides actionable upgrade recommendations.
dc_generate_commissioning_plan
Generate L1-L5 commissioning workflows with phase sequencing, test procedures, and documentation requirements per ASHRAE Guideline 0.
dc_analyze_rack_density
Analyze rack power density configurations from 5 kW to 100+ kW per rack. Covers cooling strategy selection, weight loading, and power distribution.
dc_gpu_cooling_optimizer
Optimize cooling infrastructure for GPU/AI workloads (H100, A100, H200, B200, GB200). Calculates thermal loads, recommends cooling strategies (air, rear-door, direct liquid, immersion), sizes CDUs, and projects energy savings.
dc_ups_battery_sizing
Size UPS modules and battery systems with N/N+1/2N/2N+1 redundancy. Compares VRLA vs lithium-ion with 10-year TCO analysis, floor space estimates, and weight calculations.
dc_reference_lookup
Query ASHRAE standards, Uptime Institute tier requirements, and industry best practices for data center design and operations.
Engineering Standards
All calculations comply with:
ASHRAE TC 9.9 thermal guidelines
Uptime Institute Tier Standard topology
NFPA 70 / NEC electrical code
ASHRAE Guideline 0 commissioning
Development
# Install dependencies
npm install
# Build
npm run build
# Run tests (264 tests across 7 suites)
npm test
# Start in stdio mode (MCP default)
npm start
# Start in HTTP mode
npm run start:http
# Inspect with MCP Inspector
npm run inspectArchitecture
src/
index.ts # MCP server entry point, tool registration
types.ts # TypeScript interfaces for all tools
constants.ts # Engineering constants and reference data
middleware.ts # Express middleware (auth, rate limiting, CORS)
schemas/ # Zod validation schemas per tool
services/ # Calculation engines per tool
tests/ # Jest test suites (264 tests)License
MIT - NextGen Mission Critical
Maintenance
Resources
Unclaimed servers have limited discoverability.
Looking for Admin?
If you are the server author, to access and configure the admin panel.
Related MCP Servers
- AlicenseAqualityDmaintenanceEnables AI agents to perform unit-aware engineering calculations with automatic unit conversion, dependency resolution, and access to 500+ units across 75+ categories through the CalcsLive calculation engine.313MIT
- Alicense-qualityAmaintenanceA physics engine for liquid-cooled GPU systems, exposed as an AI-callable MCP server. Enables thermal analysis, coolant comparison, flow optimization, and rack-level sizing via natural language queries.1MIT
- AlicenseAqualityCmaintenanceEstimates GPU requirements, training/inference costs, and cloud-vs-on-prem TCO for AI workloads using deterministic calculators.121MIT

security-orchestraofficial
Flicense-qualityCmaintenanceProvides deterministic, standards-based calculations for data center critical power infrastructure. Enables site selection, generator sizing, UPS sizing, NFPA 110 compliance, and more via 50+ AI agents and 8 compound chains.
Related MCP Connectors
AI-callable calculators and engineering models with real formulas. No hallucinated math.
Data-center, grid, fiber & gas infrastructure intelligence for AI agents — query and cite.
Crypto futures math: PnL, liquidation, position sizing, carry trade. 19 tools. Not AI estimates.
Latest Blog Posts
- Who's Calling? MCP Hosts Are an Identity Blind Spot (And the Spec Knows It)By Om-Shree-0709 on .mcpAgent IdentityOAuth 2.1
- Your AI Chatbot Just Exposed Your CEO's Salary to an InternBy Om-Shree-0709 on .Agent IdentityMCP SecurityOAuth Delegation
- Why MCP Servers Need Execution Sandboxing (And Why Your Current Stack Isn't Enough)By Om-Shree-0709 on .Agentic AiPrompt InjectionWebAssembly
MCP directory API
We provide all the information about MCP servers via our MCP API.
curl -X GET 'https://glama.ai/api/mcp/v1/servers/log-wade/datacenter-mcp-server'
If you have feedback or need assistance with the MCP directory API, please join our Discord server