Check a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required, found, pass / fail / not checkable and its source. Deterministic, no LLM; not a certificate or a type test. Notes: thecablecode://guide/check_cable. 2 free checks per caller per UTC day, then $0.50 USDC per check (x402).

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "check_cable"
  }
}

Input Schema

NameRequiredDescriptionDefault
designNoInstead of a designation: a thecablecode design v1 (the design field of a design_cable answer).
standardNo"auto" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, jb-t-8735-2-2016, din-vde-0250-813, din-vde-0250-809, bs-6004-2012, gb-t-18890-2. Printed names work too ("IEC 60502-2", "HD 620 10-J").
designationNoA power cable designation with its size and voltage.
constructionNoOr a datasheet's construction: {voltage: "12/20", cores, conductor: {metal, section}, core: [{kind, material, nominal, minimum}], common: [...], standards}, inside out.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Changed3 schema fields changed
    • changedInput schema / properties / construction / description
      Previous value: -"Instead of a designation: the construction as a datasheet states it: {name, voltage: \"12/20\", cores, conductor: {metal, section, shape, class, resistance, diameter}, core: [{kind, material, nominal, minimum}], common: [...], overallDiameter, flat, width and thickness (a flat cable), overallDiameterMin and overallDiameterMax (the ovality), standards: [...]}. Layers inside out."New value: +"Or a datasheet's construction: {voltage: \"12/20\", cores, conductor: {metal, section}, core: [{kind, material, nominal, minimum}], common: [...], standards}, inside out."
    • changedInput schema / properties / designation / description
      Previous value: -"A power cable designation with its size and voltage, e.g. \"NA2XS(F)2Y 1x240/25 12/20 kV\", \"AXCLJ-TT 3x95/25 12/20 kV\", \"NYY-J 4x16\", \"H07RN-F 3G2.5\": a DIN VDE, Nordic or Dutch MV or Indian name, or any name the code pages build (harmonised, British, North American, Chinese and the other systems the equivalents finder reads)."New value: +"A power cable designation with its size and voltage."
    • addedInput schema / properties / designation / examples
      Added value: +[
      +  "NA2XS(F)2Y 1x240/25 12/20 kV",
      +  "NYY-J 4x16",
      +  "H07RN-F 3G2.5"
      +]
  2. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, jb-t-8735-2-2016, din-vde-0250-813, din-vde-0250-809, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, jb-t-8735-2-2016, din-vde-0250-813, din-vde-0250-809, bs-6004-2012, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  3. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, din-vde-0250-813, din-vde-0250-809, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, jb-t-8735-2-2016, din-vde-0250-813, din-vde-0250-809, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  4. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, din-vde-0250-813, din-vde-0250-809, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  5. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  6. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  7. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-13-2025, ul-1424-2025, ul-444-2026, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  8. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-13-2025, ul-1424-2025, ul-444-2026, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  9. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  10. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  11. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  12. Changed2 schema fields changed
    • changedInput schema / properties / construction / description
      Previous value: -"Instead of a designation: the construction as a datasheet states it: {name, voltage: \"12/20\", cores, conductor: {metal, section, shape, class, resistance, diameter}, core: [{kind, material, nominal, minimum}], common: [...], overallDiameter, standards: [...]}. Layers inside out."New value: +"Instead of a designation: the construction as a datasheet states it: {name, voltage: \"12/20\", cores, conductor: {metal, section, shape, class, resistance, diameter}, core: [{kind, material, nominal, minimum}], common: [...], overallDiameter, flat, width and thickness (a flat cable), overallDiameterMin and overallDiameterMax (the ovality), standards: [...]}. Layers inside out."
    • changedInput schema / properties / designation / description
      Previous value: -"A power cable designation with its size and voltage, e.g. \"NA2XS(F)2Y 1x240/25 12/20 kV\", \"AXCLJ-TT 3x95/25 12/20 kV\", \"NYY-J 4x16\"."New value: +"A power cable designation with its size and voltage, e.g. \"NA2XS(F)2Y 1x240/25 12/20 kV\", \"AXCLJ-TT 3x95/25 12/20 kV\", \"NYY-J 4x16\", \"H07RN-F 3G2.5\": a DIN VDE, Nordic or Dutch MV or Indian name, or any name the code pages build (harmonised, British, North American, Chinese and the other systems the equivalents finder reads)."
  13. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  14. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50618-2014, iec-62930-cdv. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  15. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50618-2014, iec-62930-cdv. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  16. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  17. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  18. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  19. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, bs-5467, bs-6724, bs-7846, bs-6622. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  20. Changed1 schema field changed
    • changedInput schema / properties / standard / description
      Previous value: -"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."New value: +"\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2004, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, bs-5467, bs-6724, bs-7846, bs-6622. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
  21. Added

TDQS

A4.5/5.0
Behavior5/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Goes well beyond the readOnlyHint/openWorldHint annotations: it discloses determinism ('Deterministic, no LLM'), the exact result shape (each rule with required, found, pass/fail/not checkable and its source), the scope limit (nominal rules, not a type test), and the commercial constraint (2 free checks per caller per UTC day, then $0.50 USDC via x402). These are exactly the facts an agent needs before invoking a metered, authoritative-looking check.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Front-loaded with what is checked and what comes back, then limits, then a guide link; nothing is padding. The heavy parenthetical stacking ('a designation with size and voltage, a design, or a datasheet's construction') and telegraphic phrasing make it denser than it needs to be, but every clause earns its place.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 4-parameter, nested-object tool with no output schema, the description supplies the missing return-value picture (per-rule required/found/status/source) and the cost model. Minor gaps remain: it does not say what happens when an input is ambiguous or unmatched, or how many rules a typical check yields, but the essentials for correct invocation are present.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100%, so the per-parameter text already carries most meaning; the description still adds value by framing designation, design, and construction as mutually exclusive ways to supply the same cable and by characterising what each represents (size+voltage designation, a design v1 object, a datasheet's construction). It does not elaborate on how multiple standards interact beyond the schema's 'at most 4' note.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb and resource ('Check a power cable ... against a standard's nominal rules') and enumerates the three accepted input forms (designation, design, datasheet construction). It also draws the nearest boundary by saying it is 'not a certificate or a type test', which separates it from certification/verification-style siblings without naming them.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Gives clear context for when the tool applies (nominal rule checking of a cable against one or more standards, with 'auto' defaults) and an explicit exclusion ('not a certificate or a type test'). It stops short of naming alternatives such as design_cable or extract_datasheet for agents who still need to produce or parse an input, so no explicit when-not/alternative routing.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources