Skip to main content
Glama

The Cable Code

XLPE degassing time estimate

degassing_time
Read-only

Days an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait beside it up to 46 kV. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/degassing_time.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "degassing_time"
  }
}

Input Schema

NameRequiredDescriptionDefault
langNoAnswer language; default en.
specNoOr a design_cable spec.
inputNoinput: {tempC? (default 70), target? (share left, default 0.1), calibration?, ...}
itemsNoOr a list of {sentence | spec | design, input}, paid per item.
designNoOr a design_cable design.
sentenceNoThe cable, as design_cable takes it.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Changed6 schema fields changed
    • changedInput schema / properties / design / description
      Previous value: -"Instead of a sentence: the design field of a design_cable answer."New value: +"Or a design_cable design."
    • changedInput schema / properties / input / description
      Previous value: -"input: {tempC? (oven, 20 to 80, default 70; warned above 70), target? (share of the start left, 0.01 to 0.9, default 0.1), byproduct?: methane | polar (polar indicative), compound?: standard | low (low by-product: half the start), heatupH? (drum heat-up, h, a ramp from 20 C; default 0), startPpm? and targetPpm? (both or neither), calibration?: {tempC, days, residual (share left, GC), boundary?: sealed | open, heatupH?, conductorMm? and systemMm? (the measured cable; absent: this design)}}"New value: +"input: {tempC? (default 70), target? (share left, default 0.1), calibration?, ...}"
    • changedInput schema / properties / items / description
      Previous value: -"Instead of one: a project's list, 1 to 50 items, each {sentence | spec | design, input}; always in full, paid per item."New value: +"Or a list of {sentence | spec | design, input}, paid per item."
    • changedInput schema / properties / lang / description
      Previous value: -"Any of the site's 15 languages; default en."New value: +"Answer language; default en."
    • changedInput schema / properties / sentence / description
      Previous value: -"The cable in words or its designation, as design_cable takes it."New value: +"The cable, as design_cable takes it."
    • changedInput schema / properties / spec / description
      Previous value: -"Instead of a sentence: a spec as design_cable takes it."New value: +"Or a design_cable spec."
  2. Added

TDQS

B3.3/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare a safe, closed-world read (readOnlyHint=true, openWorldHint=false). The description adds genuinely useful behavior beyond that: it is a paid call at $5.00 USDC per calculation via x402 with no free allowance, and the answer is a band rather than a standard's certified result. It does not say what happens on payment failure or what the returned band looks like, leaving the cost/error path underspecified.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness3/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The result and its caveat are front-loaded and the pricing line earns its place, but the clause 'the AEIC CS8-20 wait beside it up to 46 kV' is compressed to the point of ambiguity. Three dense fragments; the pricing and notes sentences are clear, the AEIC one is not.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 6-parameter tool with nested objects and no output schema, the description should say more about what comes back beyond 'a band'. It does cover the x402 payment model, the estimate's non-normative nature, and a pointer to thecablecode://guide/degassing_time, which is adequate but leaves the response shape and units of the band unexplained.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, so the schema already documents lang, input (tempC default 70, target default 0.1, calibration), sentence, spec, design and items. The description adds no parameter-level meaning beyond that, so the baseline of 3 applies.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb and resource: the number of days an XLPE MV or HV core must stay in the oven before its sheath is adequately degassed, plus the method (Fick diffusion with published coefficients). No sibling tool in the catalog computes degassing, so the resource is unambiguous, though it never names a related tool such as check_cable or design_cable to anchor where it sits in a workflow.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Scope conditions are implied: it applies to MV/HV XLPE cores and the AEIC CS8-20 comparison is limited 'up to 46 kV', which tells an agent when this is the right model. There is no explicit when-not guidance and no named alternative for cases outside that voltage range or for users who want a standards-based rather than diffusion-based answer.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources