Degassing time estimate of an XLPE MV or HV core before its metallic sheath

degassing_time
Read-onlyIdempotent

The Pro degassing estimate (research/degassing/PLAN.md): how many days an XLPE core stays in the oven until a share of its crosslinking by-product is left, by Fick diffusion with published coefficients (Polymers 11 (2019) 1439; the methane D0 and Ea of IEEE PES T&D 2016 as quoted there; Electric Wire & Cable 2025 at 65 C), never a standard's result: no standard gives a degassing formula, time or residual limit. The answer is a band (an open conductor with the 2025 coefficient to a sealed conductor with the 2016 one), the cases at 50, 20, 10 and 5 % left, the curve, the highest local share, the time at 60, 65, 70 and 80 C, each step with its source and seen level, the notes and the warnings (drum turns, sheath, uniform start, no chemistry). For MV (up to 46 kV) the AEIC CS8-20 cl. 10.2 wait is given beside it as the standard's printed value (cs8), with the model's residual at its conditions. A factory measurement (input.calibration) fits an effective coefficient and replaces the band. Always paid, at its own price: on the site a member's calculation with no free part. input: {tempC? (oven, 20 to 80, default 70; warned above 70), target? (share of the start left, 0.01 to 0.9, default 0.1), byproduct?: methane | polar (polar indicative), compound?: standard | low (low by-product: half the start), heatupH? (drum heat-up, h, a ramp from 20 C; default 0), startPpm? and targetPpm? (both or neither), calibration?: {tempC, days, residual (share left, GC), boundary?: sealed | open, heatupH?, conductorMm? and systemMm? (the measured cable; absent: this design)}}. $5.00 per calculation in USDC with x402; no free allowance; a list of up to 50 items at $5.00 per item, one payment.

Input Schema

NameRequiredDescriptionDefault
langNoAny of the site's 15 languages; default en.
specNoInstead of a sentence: a spec as design_cable takes it.
inputNoinput: {tempC? (oven, 20 to 80, default 70; warned above 70), target? (share of the start left, 0.01 to 0.9, default 0.1), byproduct?: methane | polar (polar indicative), compound?: standard | low (low by-product: half the start), heatupH? (drum heat-up, h, a ramp from 20 C; default 0), startPpm? and targetPpm? (both or neither), calibration?: {tempC, days, residual (share left, GC), boundary?: sealed | open, heatupH?, conductorMm? and systemMm? (the measured cable; absent: this design)}}
itemsNoInstead of one: a project's list, 1 to 50 items, each {sentence | spec | design, input}; always in full, paid per item.
designNoInstead of a sentence: the design field of a design_cable answer.
sentenceNoThe cable in words or its designation, as design_cable takes it.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Added

TDQS

A4.3/5.0
Behavior5/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Goes well beyond the readOnly/idempotent annotations: it discloses the answer's shape (a band, not a point), the model's assumptions and their warnings (drum turns, sheath, uniform start, no chemistry), that a supplied calibration replaces the band, and the commercial trait that every call is paid at $5.00 via x402 with no free allowance, including per-item billing in list mode. That payment behavior is invisible in the annotations and is exactly what an agent needs before calling.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness3/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The core answer is front-loaded in the first clause, but the body is a single semicolon-chained paragraph that mixes outputs, warnings, standard comparison, input recital and pricing with no visual hierarchy. The input enumeration largely repeats the schema's own description string, so several lines do not earn their place twice.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

With no output schema and a deeply nested, free-form input, the description carries the full burden and does: it enumerates the returned band, the 50/20/10/5 % cases, the curve, the per-temperature times with sources, notes and warnings, plus the AEIC CS8-20 comparison for MV. Cost, calibration override and list-mode billing are all covered.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

The free-form 'input' object is only meaningful through this text: ranges and defaults for tempC (20–80, default 70), target (0.01–0.9, default 0.1), byproduct, compound, heatupH, the 'both or neither' coupling of startPpm/targetPpm, and the calibration sub-fields with fallback behavior. It loses a point only because the same block is duplicated verbatim in the schema's own input description rather than adding fresh meaning.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a precise verb and resource: how many days an XLPE core stays in the oven until a given share of crosslinking by-product remains, and names the mechanism (Fick diffusion) and coefficient sources. It also explicitly distances itself from standards ('never a standard's result') and from the AEIC printed value, so an agent can tell exactly what this returns versus a generic cable-design sibling.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Applicability is implied rather than stated: MV up to 46 kV, XLPE cores before the metallic sheath, calibration when a factory measurement exists. There is no explicit 'use this when…' or 'do not use when…' and no routing to or from siblings other than design_cable as an input format reference.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources