Wai
Server Details
Engineering intelligence: site layouts, energy, calculators, official data and company checks.
- Status
- Healthy
- Uptime
- 100.0% over the last 24 hours
- OAuth
- Works in Glama
- Last Tested
- Transport
- Streamable HTTP · MCP 2025-11-25
- URL
- ChatGPT
- –
- Claude
- Wai
TDQS
Scored across 14 tools
Most tools target clearly separate domains (trails, equipment, official data, house design, site layout), and the long descriptions explicitly steer the agent (wai_calculators returns ids, wai_calculate runs one). A few boundaries stay soft: wai_prompts vs wai_skills both search a Wai library, and wai_building_energy overlaps with the heat-loss portion of wai_design_house and the HVAC calculator in wai_calculate. These are resolvable from the descriptions but require reading them closely.
All fourteen tools use a uniform `wai_` prefix with snake_case, so the set reads as one coherent namespace. The second element mixes nouns (wai_building_energy, wai_equipment, wai_trails) with verbs (wai_calculate, wai_draw_site, wai_design_house), which is a minor inconsistency but predictable enough to navigate.
Fourteen tools is well within the productive range, and each one maps to a distinct capability (AutoLISP library, buildings, data centers, calculators, equipment, official data, trails, design, prompts, skills). No obvious filler or redundant near-duplicates that should be merged.
The surface covers the full compute-and-report lifecycle implied by the domain — discovery (wai_calculators, wai_prompts, wai_skills), computation (wai_calculate and the domain engines), and sourced data (wai_official_data). Gaps exist at the edges: no standalone cost/BOQ or report-generation tool, no warehouse/industrial building design counterpart to design_house/design_building, and no file retrieval (IFC/DWG are deferred to Wai).
Available Tools
14 toolswai_autolisp_libraryWai AutoLISP library for AutoCADBRead-onlyInspect
Wai's parametric AutoLISP routines for AutoCAD (title blocks, grids, stairs, foundations, retaining walls, steel sections, flanges, gears, single-line diagrams, road profiles, tables…) with their parameters. The .lsp files are built and sent to AutoCAD in Wai. Answer with the returned numbers, not an estimate made before the call. Typical questions: "AutoLISP routine to draw a staircase from rise and going"; "AutoLISP to draw a reinforced concrete footing with rebar"; "AutoLISP for a retaining wall section"; "AutoLISP to draw steel I-beam sections".
Inputs: category.
wai_building_energyBuilding heat loss / gain and energyARead-onlyInspect
Real heat loss and heat gain calculation of a building on the climate of its place (NASA POWER): design heating and cooling loads (kW, W/m²), monthly energy, heating / cooling plant selection. Rectangular block: length_m × width_m × storeys. use: residential, office, retail, hotel, hospital, school, industrial. Detailed up to 1,000 m² gross floor area; larger buildings get the summary (full study in Wai / WaiMAP). Answer with the returned numbers, not an estimate made before the call. Typical questions: "Heating and cooling loads and yearly energy of a 4-storey hospital 80 × 40 m in Çanakkale (40.15, 26.41)"; "Heating and cooling loads and yearly energy of a 3-storey school 50 × 25 m in Marseille, France (43.30, 5.37)"; "Heating and cooling loads and yearly energy of a 3-storey school 50 × 25 m in New York (40.71, -74.01)"; "Heating and cooling loads and yearly energy of a 4-storey hospital 80 × 40 m in Almaty, Kazakhstan (43.24, 76.89)".
Inputs: lat (required), lng (required), storeys (required), width_m (required), +4 more.
wai_calculateRun a Wai calculatorARead-onlyInspect
Run one Wai calculator by its id with its input keys and values. Numbers are computed by Wai's code, so the figures are exact for the given inputs; percentages as the key name says. Answer with the returned numbers, not an estimate made before the call. Typical questions: "LCOE of a 20 MW solar plant with 1750 kWh/kWp, capex 650 €/kW and 7 % WACC"; "IRR, NPV and payback of a 5 MW solar project selling at 65 €/MWh"; "BESS revenue stacking for a 50 MW / 400 MWh battery: arbitrage, FCR and aFRR"; "Cable size and voltage drop for 630 A over 150 m at 0.4 kV, copper XLPE".
Inputs: tool (required), inputs.
wai_calculatorsList Wai engineering and finance calculatorsARead-onlyInspect
Wai's deterministic calculators (computed by code, not by a language model): LCOE, project finance / IRR / NPV, DSCR, break-even, BESS revenue stacking, C&I and residential solar + battery, cable sizing and ampacity, short circuit, transformer sizing, earthing, surge protection, hydrogen LCOH, HVAC load, beam deflection, RC beam, pipe sizing, SPT bearing capacity, heat exchanger, open-channel flow, shaft torsion, FIDIC claim clock, construction cost, carbon offset, Damodaran valuation models and more. Returns each calculator id with its input keys and defaults. Answer with the returned numbers, not an estimate made before the call.
Inputs: query.
wai_datacenter_energyData center energy on the site climateARead-onlyInspect
Data center campus energy study on the real climate of the place: PUE, facility energy, free / adiabatic / chiller cooling hours, water use, peak cooling, waste heat for district heating, roof PV. it_mw = IT load in MW; ai = high-density AI halls. Answer with the returned numbers, not an estimate made before the call. Typical questions: "PUE, free-cooling hours and water use of a 100 MW data center in Ankara (39.93, 32.86)"; "PUE, free-cooling hours and water use of a 20 MW AI (high-density) data center in Berlin, Germany (52.52, 13.40)"; "PUE, free-cooling hours and water use of a 20 MW AI (high-density) data center in Houston, Texas (29.76, -95.37)"; "PUE, free-cooling hours and water use of a 10 MW AI (high-density) data center in Dubai, UAE (25.20, 55.27)".
Inputs: lat (required), lng (required), it_mw (required), ai.
wai_design_buildingFit an office or residential building on a parcel (Wai Building Intelligence)ARead-onlyInspect
Wai's rule engine (not the AI) fits an office building or a residential block on a real parcel: setbacks taken off, the largest footprint within the plan depth limits, site coverage (TAKS), floor-area ratio (KAKS / FAR) and height limits applied, storeys, gross / net floor area, workplaces or flats, indicative parking, and the checks (footprint inside the parcel, setbacks, coverage, FAR, height). Give the parcel as lat / lng corner points, or one point with the parcel size. Zoning values default to typical values unless given - say so. The georeferenced IFC4, the DXF site plan (UTM) and the floors are in Wai. Pre-design screening, not an architectural design or a zoning approval. Answer with the returned numbers, not an estimate made before the call. Typical questions: "Fit a residential block on a 40 × 60 m parcel at 39.93, 32.86 (Ankara) with FAR 2.0 and coverage 0.40"; "Fit a residential block on a 40 × 60 m parcel at 44.43, 26.10 (Bucharest, Romania) with FAR 3.0 and coverage 0.40"; "Fit a residential block on a 40 × 60 m parcel at 32.78, -96.80 (Dallas, Texas) with FAR 4.0 and coverage 0.40"; "Fit a residential block on a 40 × 60 m parcel at 25.20, 55.27 (Dubai, UAE) with FAR 5.0 and coverage 0.40".
Inputs: type (required), lat, lng, name, +9 more.
wai_design_houseHouse on a plot with pool, garage and the full report (Wai)ARead-onlyInspect
Wai's rule engine fits a villa, duplex or triplex villa (L-shaped, U round a courtyard, or compact for a small plot; optional basement) on a real plot with a swimming pool, a garage, storage and a perimeter wall or fence, and returns the report: site checks (setbacks, TAKS, KAKS, height), excavation and earthworks (m³, truck loads), the ground investigation to ask for, heat loss / gain and energy on the site climate, MEP for a house (heat pump or boiler, underfloor heating, split cooling, hot water, plumbing flows, electrical maximum demand and supply, PV potential), site hazards, the permits of the local authority (TR, RO or generic) and the bill of quantities - civil, mechanical, electrical. Every room is named for its use and furnished by Wai's rules (standard sizes, door zones, walkways) - furnished floor plans are in the drawings. Cost only with the user's own unit rates (unit_rates {key: rate}, currency) - Wai gives no prices. Pre-design screening; the georeferenced IFC4 is in Wai. Answer with the returned numbers, not an estimate made before the call. Typical questions: "Design a duplex villa with pool and 2-car garage on a 1,000 m² plot at 36.90, 30.71 (Antalya)"; "Design a duplex villa with pool and 2-car garage on a 1,000 m² plot at 37.98, 23.73 (Athens, Greece)"; "Design a duplex villa with pool and 2-car garage on a 1,000 m² plot at 34.05, -118.24 (Los Angeles, California)"; "Design a duplex villa with pool and 2-car garage on a 1,000 m² plot at 25.20, 55.27 (Dubai, UAE)".
Inputs: lat, lng, form, pool, +17 more.
wai_draw_siteDraw an energy / infrastructure siteARead-onlyInspect
Wai draws an indicative site layout from a plain request and returns its key numbers, a quantities table, screening checks and a link to view the plan (2D, 3D, facades). Understands: solar PV farm (MWp or ha), substation (kV, MVA), data center campus (MW IT), overhead transmission line (kV, km), underground cable, gas/water pipeline (km, DN), wind / BESS / hybrid plant, green hydrogen plant (electrolyser MW), thermal / combined-cycle plant. Returns an electrical & mechanical bill of quantities (each row with how it was counted), example products from the makers, a recommended ground investigation (boreholes, pile tests, resistivity, Vs30; with lat / lng also a SoilGrids ground screening), official market figures when a country is named, and a PDF report link. Example: "154/33 kV substation 2x50 MVA", "20 MW solar farm with trackers". DWG / DXF / IFC / Revit files are downloaded in Wai. Use this tool whenever the user asks to make / design / lay out a plant or project, and show the returned plan as the project's technical design (not images of other projects from the web). Answer with the returned numbers, not an estimate made before the call. Typical questions: "Draw a 150 MW wind farm layout at 40.19, 29.06 (Bursa) with turbine spacing"; "Draw a hybrid plant at 37.60, 14.02 (Sicily, Italy): 50 MWp PV + 25 MW / 100 MWh BESS"; "Draw a 20 MW green hydrogen electrolyser plant at 41.88, -87.63 (Chicago, Illinois)"; "Draw a 50 MW wind farm layout at 24.86, 67.01 (Karachi, Pakistan) with turbine spacing".
Inputs: request (required), lat, lng.
wai_equipmentEquipment makers and product families (Wai checked catalogue)ARead-onlyInspect
Example product families of energy equipment from several makers (European, US and Chinese): PV modules, PV inverters, BESS containers and PCS, wind turbines, electrolysers, power and dry-type transformers, MV switchgear / RMU, HV breakers and disconnectors, UPS, diesel generator sets. Each entry has only the ratings the maker's own page or datasheet states, its link and the date checked - no prices, no single brand pushed. Call with class (see class_list) or words (maker, family, rating). Suited to the equipment / vendor part of a project report. Answer with the returned numbers, not an estimate made before the call. Typical questions: "Makers and product families of utility-scale PV modules above 600 W, with ratings from their own datasheets"; "Makers and product families of string PV inverters 250–350 kW, with ratings from their own datasheets"; "Makers and product families of central PV inverters above 4 MW, with ratings from their own datasheets"; "Makers and product families of BESS containers of 5 MWh, with ratings from their own datasheets".
Inputs: class, query.
wai_official_dataOfficial open data for a project question (ECB, World Bank, Eurostat, EU tenders, EU law ...)ARead-onlyInspect
Official figures fetched now from the body that publishes them, each with its date and link - suited to the market, macro, regulatory-calendar and literature parts of a project question: ECB key interest rates (financing cost); World Bank indicators for a country (GDP, GDP per capita, inflation, population, unemployment, access to electricity, renewable share); Eurostat household and industrial electricity prices (EU, candidates incl. Türkiye); public tenders for solar, wind, BESS, substations, roads, bridges, hospitals from TED (EU), World Bank-financed procurement (all borrower countries) and UK Find a Tender, with the buyer's published contact; job openings from public boards (ReliefWeb, Arbeitnow, Remotive) by field, seniority, country or remote; World Bank-financed projects of a country (pipeline and active: who invests in what before the tenders); company records from open registers (France Sirene, Norway Brønnøysund, US SEC EDGAR); a Romanian company by name (its CUI is found, then ANAF / courts); mining sites of a country with the oil / diesel power plants mapped near them (OpenStreetMap - off-grid PV + BESS targeting); Romanian company record, filed financials and court cases by CUI or name (ANAF, portal.just.ro); counterparty check of an e-mail, phone, website or EU VAT number (domain age, certificate, sub-domains, SPF / DMARC, VIES, LEI, OFAC / UN / UK sanctions) - write "check <e-mail / site / phone / VAT>"; EU regulations, directives and decisions by topic from EUR-Lex (Publications Office); Turkish Court of Cassation (Yargıtay) decisions by topic; a country's public holidays (construction calendar); books from Open Library; scholarly papers from OpenAlex; plus, when they fit, up to two read-only servers of the public MCP registry that Wai has reached itself (energy, engineering, GIS, weather, data, law, finance, travel, science), each table marked third-party. Write the question in plain words naming the country and the data wanted (e.g. "Romania electricity price, inflation and GDP; solar and BESS tenders; ECB rates"). Returns one table per source, a view page and a PDF report link (report_pdf) to give the user. Answer with the returned numbers, not an estimate made before the call. Typical questions: "Industrial and household electricity prices in Türkiye (Eurostat), with inflation and GDP growth"; "Industrial and household electricity prices in Romania (Eurostat), with inflation and GDP growth"; "GDP per capita, inflation, access to electricity and renewable share in United States (World Bank)"; "GDP per capita, inflation, access to electricity and renewable share in Saudi Arabia (World Bank)".
Inputs: question (required), title.
wai_promptsWai prompt library: 30,000+ ready questions and the Wai tool that answers eachARead-onlyInspect
Search Wai's library of more than 30,000 ready questions - engineering (electrical, mechanical, architectural), energy and grid (solar, wind, BESS, hydro, hydrogen, data centers), finance, legal (EU law, Yargıtay), HR, country and sector questions for 80 countries, travel and trails, reports and LinkedIn posts, open data - by words, category, country (ISO code) or sector. Each result says which Wai tool answers it (wai_draw_site, wai_calculate, wai_official_data, wai_trails, WaiMAP ...) and how to call it. Use it when the user asks what Wai can do, wants ideas or examples for a field or a country, or when you are not sure which Wai tool fits a request. Answer with the returned numbers, not an estimate made before the call.
Inputs: limit, query, sector, country, +1 more.
wai_skillsWai skills and W-Digamma catalogueARead-onlyInspect
Search Wai's verified skills and modules (W-Digamma): 20 Energy & EPC skills (tender reader, FIDIC risk scan, site screening, grid connection, PV, BESS, wind, hydro, hydrogen, cable, transformer, substation, HVDC, CAPEX, LCOE, project finance, BESS revenue, bid comparison, claims, commissioning) plus Wai modules (W Legal, WBook LLM, WaiMAP, Studio, wHendese CAD, Deep Research, report types). Give id to get one skill's method outline, inputs it needs and an example prompt. The full skill runs inside Wai. Answer with the returned numbers, not an estimate made before the call. Typical questions: "Read a solar EPC tender and list the key requirements"; "FIDIC risk scan of a construction contract"; "Grid connection steps and studies for a 100 MW solar plant"; "Site screening checklist for a wind farm".
Inputs: id, query, category.
wai_trail_detailOne trail: conditions, effort and safety (Wai Trails)ARead-onlyInspect
One Wai Trails route by its route id: length, ascent / descent, height range, effort and walking time, a go / caution verdict for a date with weather, daylight, animals recorded nearby and other safety points, a map and the Wai Trails link (3D fly-through video, GPX). Answer with the returned numbers, not an estimate made before the call.
Inputs: id (required), date, kind.
wai_trailsHiking and cycling trails near a place (Wai Trails)ARead-onlyInspect
Marked hiking or cycling routes near a place from Wai Trails: name, length, height gain, highest point, grade, best months, a map with the routes drawn and a link to each route in Wai Trails (3D fly-through video, elevation profile, GPX, reviews). Give place (any town, valley, park) or lat / lng. Answer with the returned numbers, not an estimate made before the call. Typical questions: "Best hiking trails near Kaçkar Mountains, Rize with length, ascent and a map"; "Best hiking trails near Dolomites, Italy with length, ascent and a map"; "Best hiking trails near Yosemite, California with length, ascent and a map"; "Best hiking trails near Swiss Alps, Zermatt with length, ascent and a map".
Inputs: lat, lng, kind, place, +1 more.
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
Related MCP Connectors
Engineering and GIS tools for energy and infrastructure sites, computed by real engines.
27 engineering compliance and calculation tools for the built environment (UK, EU, UAE).
Heating, ventilation and energy engineering calculations and diagnostics for AI agents.
UK property data: EPC, flood risk, planning, sale prices, MEES 2030 checks and grants.
Related MCP Servers
- AlicenseCqualityDmaintenance27 deterministic engineering compliance and calculation tools for the built environment (data-centre PUE and EED, EPBD, NIS2, Eurocode, UAE compliance), callable by AI agents via MCP and REST API. Free tier; every result cites the governing standard.27MIT
- AlicenseAqualityDmaintenanceProvides professional-grade data center engineering calculations including cooling, power, GPU thermal optimization, UPS/battery sizing, tier classification, and commissioning workflows, compliant with ASHRAE and Uptime Institute standards.8161 npm1MIT

security-orchestraofficial
FlicenseNot gradedqualityCmaintenanceProvides deterministic, standards-based calculations for data center critical power infrastructure. Enables site selection, generator sizing, UPS sizing, NFPA 110 compliance, and more via 50+ AI agents and 8 compound chains.-- AlicenseAqualityDmaintenanceAI-powered terrain analysis for any location on Earth. Uses super-resolution and computes environmental risk metrics including erosion, water flow, and a composite Site Intelligence Score.3MIT
Glama MCP Gateway
Add one secure layer between your agents and this server.