changedInput schema / properties / cpc / description
Previous value: -"For cpc: {kind armour | core | separate | conduit (a steel conduit or trunking) | bare (a bare conductor) (default the armour where the design has one), basis iec | bs, column tp70 | tp90 | ts90, section_mm2 (required for conduit and bare), metal Cu | Al (separate) or Cu | Al | steel (bare), condition visible | normal | fire (bare: Table 54.6 / A.54.6), system TN | TT | IT (IT: a second fault, 411.6.4), circuit final | distribution, current ac | dc (Table 41.1's d.c. columns), u0_v (line to earth, default 230), ia_a (the current that operates the device in time), or device (a BS 7671 fuse bs88-2 | bs88-3 | bs3036 | bs1362, or a circuit-breaker type B | C | D) with device_a (its rating: the Tables 41.2 to 41.4 Zs at U0 230 V), length_m (the route length: the cable's own R1 + R2 at its operating temperature against the largest Zs)}."New value: +"The protective conductor check: {kind, system, device and device_a or ia_a, length_m, ...}."
changedInput schema / properties / fault / description
Previous value: -"For cpc: {ka (the fault current), seconds (default fault_s)}: the adiabatic check of the armour or protective conductor (IEC 60364-5-54:2011 Annex A, BS 7671 Tables 54.2 to 54.6) up to 1 kV."New value: +"For cpc: {ka, seconds}, the adiabatic check up to 1 kV."
changedInput schema / properties / formats / description
Previous value: -"Files to include: xml, dxf, svg, csv, glb (base64), step (STEP AP214 text), pdf (datasheet, base64)."New value: +"Files to include: xml, dxf, svg, csv, glb, step, pdf (datasheet)."
changedInput schema / properties / installation / description
Previous value: -"For ratings.current: how the cable is installed; the designer's defaults for what is not given (buried 0.8 m, 20 °C ground, 1.5 K·m/W, trefoil, alone). At 0.6/1 kV group, arrangement, clearance, trays and h3_pct give the IEC 60364-5-52 B.52.17 to B.52.21 (BS 7671 4C1 to 4C5) grouping and the E.52.1 harmonic factors; reel_drum puts a flexible cable on a reeling drum (NFPA 79 Table 12.7.3); restrained (buried or clamped) is read by ratings.short_circuit. The answer lists the defaults used and the fields the cable's table does not read."New value: +"For ratings.current: how the cable is installed; what is not given takes the defaults the answer lists."
addedInput schema / properties / installation / properties / air_c / description
Added value: +"Air temperature, °C."
changedInput schema / properties / installation / properties / air_formation / description
Previous value: -"0.6/1 kV single-core cables in free air: method F with 3 loaded, trefoil (default) or flat (touching); method G, horizontal (default) or vertical."New value: +"0.6/1 kV single-core in free air."
changedInput schema / properties / installation / properties / arrangement / description
Previous value: -"0.6/1 kV in air: how the group lies (bunched, on a wall or ceiling, on perforated, vertical or unperforated trays, on ladders, spaced); default bunched."New value: +"0.6/1 kV in air: how the group lies."
changedInput schema / properties / installation / properties / au_method / description
Previous value: -"rating_basis au (AS/NZS 3008.1.1:2025 Tables 3.5 to 3.8): air (default), spaced, trefoil, conduit, buried or duct, the ones the design's cores take; buried and duct read ground_c (default 25), depth_m (default 0.5) and soil_k_m_per_w (default 1.2), the others air_c (default 40)."New value: +"rating_basis au: the installation."
changedInput schema / properties / installation / properties / circuit_use / description
Previous value: -"0.6/1 kV, IEC 60364-5-52 Table 52.2: power (default), signal or electronic, which sets the smallest conductor (minimum in the answer when the design is below it)."New value: +"0.6/1 kV, Table 52.2: sets the smallest conductor."
changedInput schema / properties / installation / properties / clearance / description
Previous value: -"0.6/1 kV: touching (default), oneDiameter (multicore cables on an IEC tray), or the clearance in the ground between cables or ducts, m (0.125 to 1.0)."New value: +"0.6/1 kV: touching, oneDiameter, or a ground clearance, m."
changedInput schema / properties / installation / properties / cord_carrying / description
Previous value: -"A North American flexible cord (NFPA 79 2024 Table 12.8.2 at 30 °C): 3 current-carrying conductors (column A, default) or 2 (column B); a cord of two conductors is always column B."New value: +"North American cord: current-carrying conductors."
addedInput schema / properties / installation / properties / depth_m / description
Added value: +"Laying depth, m."
addedInput schema / properties / installation / properties / ground_c / description
Added value: +"Ground temperature, °C."
addedInput schema / properties / installation / properties / group / description
Added value: +"Cables or circuits side by side."
changedInput schema / properties / installation / properties / group / maximum
Previous value: -9007199254740991New value: +12
changedInput schema / properties / installation / properties / group / minimum
Previous value: --9007199254740991New value: +1
changedInput schema / properties / installation / properties / h3_pct / description
Previous value: -"0.6/1 kV 4- and 5-core cables: the third-harmonic share of the phase current, % (IEC 60364-5-52 Table E.52.1)."New value: +"0.6/1 kV 4- and 5-core: third-harmonic share, %."
changedInput schema / properties / installation / properties / iec_method / description
Previous value: -"IEC 60364-5-52 reference method, 0.6/1 kV IEC basis (Table B.52.1): A1 / B1 single-core in conduit, A2 / B2 multicore in conduit, C on a wall, D1 in ducts, D2 direct in the ground, E / F in free air, G single-core spaced one diameter in free air."New value: +"IEC 60364-5-52 reference method, 0.6/1 kV."
changedInput schema / properties / installation / properties / is_circuit / description
Previous value: -"rating_basis is3961, IS 1554-1 and IS 7098-1 (IS 3961 Parts 2 and 6), as the rating panel: three (a.c. three-phase, three single-core cables; default), single (a.c. single-phase: a single-core cable as one of two, a two-core cable itself) or dc (two single-core cables or one two-core cable; Part 2 Tables 9 to 12, Part 6 Tables 5 and 6). A single-core cable takes all three, a two-core cable single (its default) or dc, three to five cores three only; a circuit the cable does not take falls back to its first."New value: +"rating_basis is3961: the circuit."
changedInput schema / properties / installation / properties / is_method / description
Previous value: -"IS 694 on IS 3961 (Part 5): clipped (default), enclosed (in conduit or trunking), defined (the defined conditions) or trefoil (single-core, three-phase only)."New value: +"IS 694: the installation method."
changedInput schema / properties / installation / properties / is_pvc / description
Previous value: -"rating_basis is3961, IS 1554-1 only: the PVC of cl. 4.1, A (general purpose, 70 °C, default) or C (heat resisting, 85 °C: IS 3961 Part 2 cl. 2 a, the 85 °C tables)."New value: +"rating_basis is3961, IS 1554-1: the PVC grade."
addedInput schema / properties / installation / properties / laying / description
Added value: +"Buried, in a duct, or in air."
changedInput schema / properties / installation / properties / lead_alloy / description
Previous value: -"ratings.short_circuit: yes when the lead sheath is a lead alloy (IEC 60986:2000+A1:2008 Table 3: 210 °C, lead 170 °C)."New value: +"Short circuit: the lead sheath is a lead alloy."
changedInput schema / properties / installation / properties / loaded / description
Previous value: -"0.6/1 kV single-core cables (not method G): a single-phase circuit, 2 loaded conductors, or three-phase, 3 (default); a two-core cable is always 2."New value: +"0.6/1 kV single-core: loaded conductors."
changedInput schema / properties / installation / properties / loaded_cores / description
Previous value: -"An HD 603 cable of more than four cores: the loaded cores (DIN VDE 0276-1000 Table 13); default 3."New value: +"HD 603, over four cores: loaded cores."
changedInput schema / properties / installation / properties / loaded_cores / maximum
Previous value: -9007199254740991New value: +61
changedInput schema / properties / installation / properties / loaded_cores / minimum
Previous value: --9007199254740991New value: +1
changedInput schema / properties / installation / properties / method / description
Previous value: -"BS 7671 reference method (British LV cables)."New value: +"BS 7671 reference method."
changedInput schema / properties / installation / properties / mv_install / description
Previous value: -"Type MV and URD (NFPA 70 2026, 315.60 Tables (C)(1) to (C)(20)): airIsolated, airTriplexed, conduitAir, duct (default), buried or buriedTriplexed; the tables the construction has. group picks the circuits of the table (duct 1, 3 or 6; buried 1 or 2); air_c (default 40) or ground_c (default 20) the ambient."New value: +"Type MV and URD, NEC 315.60: the installation."
changedInput schema / properties / installation / properties / mv_temp_c / description
Previous value: -"Type MV and URD: the 90 °C (MV-90) or 105 °C (MV-105) column; default 90 for URD, 105 for MV-105."New value: +"Type MV and URD: the 90 or 105 °C column."
changedInput schema / properties / installation / properties / phase / description
Previous value: -"IS 694 single-core on IS 3961 (Part 5): a single-phase (2 cables) or three-phase (3 or 4 cables, default) circuit."New value: +"IS 694 single-core: the circuit."
changedInput schema / properties / installation / properties / protection / description
Previous value: -"IS 694 on IS 3961 (Part 5): close (default) or coarse excess current protection, which picks the Table 8 ambient row."New value: +"IS 694: the excess current protection."
changedInput schema / properties / installation / properties / rating_basis / description
Previous value: -"A 0.6/1 kV IEC design (not HD 603): iec (default, IEC 60364-5-52:2009), de (DIN VDE 0298-4:2013-06, the German tables of the same methods, its one differing cell named in override; no D2) or au (AS/NZS 3008.1.1:2025 with au_method; PVC not rated). An HD 620 S3:2023 Section 10-C design: iec (default, IEC 60502-2 Annex B with its factors) or hd620, the section's own Tables 7 to 10 (laying buried or air, formation for single cores: trefoil, or flat for flatTouching and flatSpaced) at the conditions of its clause 5 only (0.7 m, ground 20 °C, soil 1.0 / 2.5 K·m/W, load factor 0.7 in the earth; air 30 °C, load factor 1.0), since the section gives no conversion factors; no table for ducts. An Indian design (IS 1554-1, IS 7098-1, IS 7098-2, IS 694): iec (default, the IEC tables as for any design) or is3961. IS 1554-1 / IS 7098: the IS 3961 Part 2, 6 or 7 tables with their ambient, depth and soil factors (laying, formation, air_c default 40, ground_c default 30, depth_m default the depth of the part, soil_k_m_per_w default 1.5) and their group tables (group: circuits or multicore cables, one alone by default; in the ground or a duct spacing_mm, the clear distance between them, 0 touching, and tiers for multicore cables laid direct, Part 2 / 6 only; in air support tray (perforated), vertical or ladder, trays, and clearance oneDiameter for spaced multicore cables, else touching). IS 694: IS 3961 (Part 5) with is_method, phase (single-core), protection, air_c (default 40) and group (the circuits, cl. 4.2); flexible cables and cords take Table 5 with air_c and group only."New value: +"The rating tables; default iec."
changedInput schema / properties / installation / properties / reel_drum / description
Previous value: -"A flexible cable (class 5 or 6, or a cord) on a motor-driven reeling drum, as the rating panel: cylindrical (ventilated, wide flanges), radial-vent or radial-closed (spiral). amps becomes the rating on the drum, times the NFPA 79 (2024) Table 12.7.3 factor, whole amperes down; reel gives the factor, the DIN VDE 0298-4:2013-06 Table 27 factor beside it and the drum rules of 13.4.3.2."New value: +"A flexible cable on a reeling drum."
changedInput schema / properties / installation / properties / reel_layers / description
Previous value: -"With reel_drum cylindrical: the layers wound, 1 to 5 (Table 12.7.3 gives factors for 1 to 4; DIN VDE 0298-4 Table 27 for 1 to 5). Default 1."New value: +"With reel_drum cylindrical: layers wound."
changedInput schema / properties / installation / properties / reel_layers / maximum
Previous value: -9007199254740991New value: +5
changedInput schema / properties / installation / properties / reel_layers / minimum
Previous value: --9007199254740991New value: +1
changedInput schema / properties / installation / properties / restrained / description
Previous value: -"ratings.short_circuit: yes when the cable is buried directly, clamped or bent tighter than specified (IEC 60986 3.2.2, IS 16269 3.2.2): a thermoplastic insulation's (PVC, PE) short-circuit limits are taken 10 °C lower. Default no."New value: +"Short circuit: buried, clamped or bent tight."
addedInput schema / properties / installation / properties / soil_k_m_per_w / description
Added value: +"Soil thermal resistivity, K·m/W."
addedInput schema / properties / installation / properties / spacing_mm / description
Added value: +"Group spacing, mm; 0 touching."
changedInput schema / properties / installation / properties / strip_mm / description
Previous value: -"ratings.short_circuit: an interlocked armour's strip thickness, mm (no maker prints it; without it the layer is listed in unrated)."New value: +"Short circuit: armour strip thickness, mm."
addedInput schema / properties / installation / properties / support / description
Added value: +"In air with a group: the support."
changedInput schema / properties / installation / properties / tiers / description
Previous value: -"IS 3961 (Part 2 / 6) Table 27 / 21: multicore cables laid direct in the ground in tiers (rating_basis is3961, group above 1)."New value: +"rating_basis is3961: buried in tiers."
addedInput schema / properties / installation / properties / trays / description
Added value: +"Trays one above the other."
changedInput schema / properties / installation / properties / trays / maximum
Previous value: -9007199254740991New value: +3
changedInput schema / properties / installation / properties / trays / minimum
Previous value: --9007199254740991New value: +1
changedInput schema / properties / lang / description
Previous value: -"Any of the site's 15 languages for the answer's words (the sentence itself is read in any of them)."New value: +"Language of the answer's words; the sentence is read in any."
changedInput schema / properties / load / description
Previous value: -"For voltage_drop and sizing: {length_m (required), amps or kw (default the design's own rating), phases 1 | 3, volts, pf (0.85), temp_c (the insulation's normal temperature), hz, limit_pct (a Table G.52.1 row 3, 5, 6, 8 raised beyond 100 m, or an own limit; default 5), conduit pvc | al | steel (NEC wires, Chapter 9 Table 9), formation touching | flat | spaced (single-core cables)}. IEC 60364-5-52 Annex G with the IEC 60287-1-1 a.c. resistance, BS 7671 Tables 4E4B, 4D4B, 4E3B, 4D3B or NEC Chapter 9 Table 9, and the smallest size by current, by drop and by both."New value: +"For voltage_drop and sizing: {length_m (required), amps or kw, phases, volts, pf, limit_pct, conduit, formation}."
changedInput schema / properties / nec / description
Previous value: -"North American wires: {ocpd_a (the overcurrent device; default from the ampacity), phase_min (250.122(B): the size before upsizing), install raceway | air | messenger (Table 310.20, single THHN, XHHW-2, USE-2, THW-2) | annexB (informative Annex B Table B.2(3), MC, MC-HL, TC, UF-B of 2 or 3 conductors in free air), ambient_c, carrying, termination_c 60 | 75 | 90}: nec.ampacity (NEC 310.16, 310.17, 310.20 or Table B.2(3)) and nec.egc (Table 250.122). A CSA design (T90, RW90, NMD90, AC90, TECK90): install, ambient_c, carrying and termination_c set ratings.current by CSA C22.1:24 Tables 1 to 4, 5A, 5C and 19."New value: +"North American wires: {ocpd_a, install, ambient_c, carrying, termination_c}: NEC ampacity and EGC; CSA designs by C22.1."
changedInput schema / properties / sentence / description
Previous value: -"The cable in words, any of the 15 site languages: voltage, cores, section, conductor metal, screen, sheath, watertightness, armour. What is not said takes a default, and the answer lists which."New value: +"The cable in words (any site language) or a designation; what is not said takes a default, listed in the answer."
addedInput schema / properties / sentence / examples
Added value: +[
+ "NA2XS(F)2Y 1x240/25 12/20 kV",
+ "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight",
+ "NYY-J 4x16"
+]
changedInput schema / properties / spec / description
Previous value: -"Instead of a sentence: {voltage: \"12/20\", cores: 3, section: 95, metal, screen, screenType, screenSection, screenLay (helical | interstices), insulation, sheath, watertight, armour}; add standard (an id from design_presets: HD620-10C, BS6724, UL-NMB, EN50525-2-21 ...) for that family's own build at the nearest voltage, size and count it lists; with an HD 620 section that lays three single cores up (HD620-10E1, -10E2, -10I1, -10I2, -10I3 ...), bundle none | messenger | earth and cores 3 builds the bundle; with IS9968-1, is9968 {kind, grade, ecc} picks the table and grade (ecc true: a flat twin with its bare ECC); with GOST1508, gostMark the mark. A LAN cable instead: {lan: {category cat5e ... cat8.2, shield, awg, and workArea (IEC 61156-6), cord (IEC 61156-8 / -10) or riser (25 pairs, IEC 61156-4) where the category is built so}, sheath PVC | LSZH}."New value: +"Or {voltage: \"12/20\", cores: 3, section: 95, metal, screen, insulation, sheath, armour, standard (a design_presets id), ...} or {lan: {category, shield, awg}}."
changedInput schema / properties / test_variant / description
Previous value: -"For after_installation: a national variant of the tests after installation (HD620-10A, HD620-10C, HD620-10J, HD620-10M, HD620-10R, BS6622, IS1255, BS7846, BS5467, HD603-3F, HD603-G); default the one the design's standard implies."New value: +"A national variant of the tests after installation; default the design standard's."