Official

set_protection

Configure rail trip limits for overcurrent and undervoltage protection: set overcurrent up to 7500 mA and an optional undervoltage threshold; use 0 to disable either limit.

Instructions

Set the rail trip limits (0 disables either). Overcurrent is capped at 7500 mA: the board's continuous budget is ~5 A. Resets at power-up.

Input Schema

NameRequiredDescriptionDefault
overcurrent_maYes
undervoltage_mvNo

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.1.0

TDQS

A3.6/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description carries the full burden and does substantive work: it discloses the 7500 mA hard cap, the ~5 A continuous budget as practical context, and that settings reset at power-up (non-persistent). It stops short of saying what happens on a trip or who consumes the resulting fault, but the safety-critical behavior is well conveyed.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Three tight sentences with zero filler; the disable rule and safety cap are front-loaded and the persistence note closes cleanly.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

A hardware-mutating, no-annotation, no-output-schema tool needs strong behavioral coverage. The description covers caps and persistence but omits trip behavior, undervoltage semantics, and any return/confirmation detail an agent might want.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 0%, so the description must compensate. It clarifies overcurrent_ma's cap (7500 mA) and that 0 disables both limits, but adds nothing about undervoltage_mv's range or behavior beyond the disable case, leaving one parameter largely undocumented by the name alone.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb (Set) and resource (rail trip limits), making clear it configures protection thresholds rather than measuring or clearing faults like its siblings. It doesn't explicitly name a sibling alternative, but the purpose is unambiguous.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

The parenthetical '(0 disables either)' gives a useful operating hint on how to turn off a limit, but there is no guidance on when to call this versus siblings like clear_faults or measure_current, nor any prerequisite context.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.