Rigol MHO98 示波器的 Model Context Protocol (MCP) 服务器。 基于官方《MHO98 Programming Guide》(PGA45102-1110) 做全量参数化封装, 通过 PyVISA (raw TCP socket 5555 / USBTMC) 控制仪器。
手册摘要:
docs/NOTES.md;功能规划:docs/PLAN.md;手册原文:docs/MHO98_ProgrammingGuide_EN.pdf默认暴露 18 个工具(动作/配置三层结构)(
MHO98_TOOL_PROFILE=full可全量暴露 142 个);手册全部 28 个命令子系统逐命令核对覆盖——改状态走configure(scope, target, params),查状态走get_config(subsystem, target, full),其余是动词(run/autoscale/measure/capture/screenshot/save/navigate)波形数据只落盘(CSV/NPY),绝不在 MCP 返回值中内联采样数组,防止撑爆大模型上下文;返回值为统计摘要 + 文件路径,供后续脚本按协议解析
快速开始
cd /Users/andylos/mcp_gen/rigol/mho98
python3 -m venv .venv
.venv/bin/pip install -e . # 或 pip install mcp'>=1.2,<2' pyvisa pyvisa-py numpy
.venv/bin/python -m pytest tests/ # 离线单元测试(mock 仪器)
.venv/bin/python scripts/probe_device.py # 真机全功能自检Related MCP server: pyMSO5000 MCP Server
配置(环境变量)
变量 | 默认 | 说明 |
|
| VISA 资源串;USB 形如 |
| 自动检测 | macOS 直连 link-local 网段时绑定本机源地址(en 口 169.254.*) |
|
| 波形 CSV/NPZ、截图、设置文件的保存目录 |
|
| 工具暴露面: |
macOS 直连网线注意:仪器使用 link-local 地址(169.254.x.x)时,系统默认把流量 路由到主网卡导致连不上。本服务会自动发现本机 169.254.* 地址并绑定;若仍有问题, 可
sudo route -host add 169.254.112.67 -interface en7持久修复。
接入 MCP 客户端
ZCode(.zcode/settings.json)或 Claude Desktop(claude_desktop_config.json):
{
"mcpServers": {
"mho98": {
"command": "/Users/andylos/mcp_gen/rigol/mho98/.venv/bin/python",
"args": ["-m", "mho98_mcp.server"],
"cwd": "/Users/andylos/mcp_gen/rigol/mho98",
"env": {
"MHO98_RESOURCE": "TCPIP0::169.254.112.67::5555::SOCKET",
"MHO98_DATA_DIR": "/Users/andylos/mcp_gen/rigol/mho98/data",
"MHO98_TOOL_PROFILE": "lean"
}
}
}
}工具暴露面:lean(默认,18 个)/ full(142 个)
142 个工具的全量 schema 对大模型上下文负担太重。默认 lean profile 按
「动作 / 配置」结构轴切分,规则一句话:改状态走 configure,查状态走
get_config,其余是动词(MHO98_TOOL_PROFILE=full 切回全量暴露,功能等价)。
① 配置写(1 个)
configure(scope, target=None, params=None, extra=None)scope 覆盖全部 32 个配置域:channel / timebase / acquire / autoset / display /
trigger / trigger_common / bus / math / reference / awg / awg_modulation /
awg_output / bode / thresholds / statistics / cursor / counter / dvm / measure /
histogram / mask / search / navigate / record / la / system / lan / save / smb /
ieee4888 / datetime。target 是二级选择器(触发类型、"1/CAN" 式总线+协议、
通道/槽位号、measure 小节名)。示例:
configure("channel", "1", {"scale": 0.05, "coupling": "AC", "probe": 10})
configure("trigger", "CAN", {"baud": 500000, "when": "ID"})
configure("bus", "1/SPI", {"sclk": "CH1", "miso": "CH2"})
configure("awg", "1", {"function": "SINusoid", "frequency": 10e3})
configure("awg_output", "1", {"state": True, "sync_phase": True})params 的键按底层包装函数的签名校验:拼错键名报 ValueError 并列出全部
合法键——错误信息即完整参数文档。
② 配置读(1 个)
get_config(subsystem, target, full) ——32 个子系统读回合一(通道/时基/任意
触发类型/总线/数学/AWG/录制/LA/LAN/SMB/IEEE488.2/选件等;选件查询带挂死守卫,
默认跳过)。
③ 动作(16 个)
类别 | 工具 |
会话/状态 |
|
采集动作 |
|
存储/导航 |
|
长尾/组合参数仍可通过 configure(..., extra={"KEYWORD": value}) 白名单透传到
:子系统:KEYWORD value(白名单按手册逐命令核对,非法关键字报 ValueError)。
已验证固件特性(00.01.00,实机 MHO9A274501356)
:SYSTem:OPTion:STATus?/:OPTion:VALid?会挂死(不响应),get_system_info已跳过;get_option_status默认跳过,仅opt_in=True才真正查询:DVM:CURRent?在 DVM 关闭时挂死,read_dvm已做使能守卫:CURSor:MANual:TYPE合法值为TIME|AMPLitude(非 X/Y):TRIGger:PATTern:PATTern需要H,H,L,L逗号分隔(工具自动转换HHLL):DISPlay:GRADing:TIME只接受MIN|数值秒|INFinite(不接受1S/1.0):NAVigate:MODE需要 STOP 状态(configure_navigate(stop_first=True))SCPI 错误入队有延迟,写后错误检查带 50 ms 稳定期防止误归属
手册逐条核对带来的修正(v0.1 → v0.2)
:CHANnel<n>:POSition是偏置电压(V)而非垂直格数测量阈值命令为
:MEASure:SETup:MAX/MID/MIN(非:MEASure:THReshold:*);统计查询必带类型参数:MEASure:STATistic:ITEM? <type>,<item>PATTern/DURation 触发的
LEVel需<源>,<电平>二元形式;holdoff下限 8 ns此型号无
:MATH<n>:DATA?,数学波形经:WAVeform:SOURce MATH<n>读取;REF 插槽为 1–10;FFT 窗函数集为 {RECTangle|BLACkman|HANNing|HAMMing|FLATtop|TRIangle}AWG 调制仅支持 AM/FM/PM(无 SWP/Burst);AM 深度 0–120%;频率 2 mHz–100 MHz
Bode:
sweep_type合法值LOG|LINE;:BODeplot:VOLTage需<量程>,<幅值>双参数LA 阈值按 POD 组设置(POD1=D0–D7,POD2=D8–D15),非逐通道
录制帧间隔命令为
:RECord:WRECord:FINTerval(非 INTerval);搜索类型仅 EDGE|PULSepower_on合法值LATest;语言设置用 13 种长格式:SAVE:IMAGe:DATA?截图与:SAVE:*/:LOAD:*U 盘路径、SMB 共享均已封装
数据文件格式
波形 CSV:两行
#注释头(含 preamble 换算参数)+t_s,v_V两列波形 NPY:
np.load(f)["t_s"]/["v_V"](npz,RAW 大采集推荐)电压换算:
v = (code - yorigin - yreference) × yincrement
Available Tools
142 toolsautoscaleB
Autoset with options, then execute :AUToset.
enable_channels: True = only test the currently enabled channels; False = scan CH1..CH4 in sequence and enable the ones carrying signals view_overlap: True = stack channel waveforms; False = tile them top-to-bottom on the screen peak_search: peak-peak priority (best for signals with a large DC shift) keep_coupling: keep the channel coupling (else DC is applied) lock_timebase: lock the AUTO key, i.e. disable the AUTO function (manual 3.2.6; :AUToset:ENAble False is the equivalent master switch)
Inputs: peak_search, view_overlap, keep_coupling, lock_timebase, +1 more. Returns: result
clear_statusB
Send *CLS: clear event registers and error queue.
Inputs: no named parameters. Returns: result
configure_awgA
Configure generator channel GI/GII (SOURce1/2).
function: SINusoid|SQUare|RAMP|NOISe|DC|ARB|EXPRise|EXPFall|ECG1|GAUSsian| LORentz|HAVersine|SINC (manual 3.25.2; abbreviations allowed). frequency in Hz, 2 mHz to 100 MHz (per-waveform limits: square/ramp/arb and built-in waveforms top out at 20 MHz, ramp at 2 MHz; DC/Noise ignore it). period in s, 10 ns to 500 s — reciprocal of frequency; when both are given the period is written last and therefore wins. amplitude in Vpp, 1 mV to 20 V (50-ohm load tops out at 10 Vpp, and above 50 MHz the limits halve). offset in V, |offset| <= 10 V (actual limit depends on amplitude/impedance). high/low absolute levels in V within +/-10 V; when both are given high must stay above low. phase in degrees, 0 to 360. duty_percent for SQUare, 1 to 99. ramp_symmetry_percent for RAMP, 0 to 100. impedance: OMEG (HighZ, 1 Mohm) | FIFTy (50-ohm load); HIGHZ/50/LOAD also OK. load_arbitrary: path of a stored arbitrary waveform file, e.g. "D:/123.csv" (local storage "C:/", external "D:/"); use together with function="ARB". Use sync_awg_phase() for the align-phase operation and get_awg_full_config() to read every setting back.
Inputs: channel (required), low, high, phase, +9 more. Returns: result
configure_awg_modulationB
Generator modulation AM|FM|PM (per manual :SOURce:MOD, 3.25.15-3.25.25).
This model's manual defines the modulation types AM, FM and PM only (no SWP/ARB/BURSt). type: AM|FM|PM. am_depth_percent: 0-120%. fm_deviation_hz: 2 mHz up to the current carrier frequency. pm_deviation_deg: 0-360. Internal modulation frequency in Hz: 2 mHz-1 MHz. Internal waveform shape: SINusoid|SQUare|TRIangle|UPRamp|DNRamp|NOISe. extra: only MOD subsystem keywords documented in section 3.25 are allowed, e.g. {"MOD:FM:DEViation": 200} (case-insensitive, canonicalized).
Inputs: channel (required), type, extra, enable, +9 more. Returns: result
configure_bodeA
Bode plot configuration (requires generator option; manual 3.5.1-3.5.11).
sweep_type: LOG|LINE (DECade/LINear spellings are accepted as aliases). ref_in/ref_out: DUT input/output channel, CH1..CH4 (CHAN/CHANnel forms OK). start_hz: 10 Hz-3 MHz; stop_hz: 100 Hz-30 MHz; when both are given the manual constraint start*10 <= stop is enforced. points: sweep points per decade, 10-100. voltage: sweep amplitude in V, 20 mV-10 V, applied to the frequency range given by voltage_range (default ALL, i.e. a unified amplitude); voltage_range: ALL|10|100|1K|10K|100K|1M|10M|25M (numeric forms like 1000 or 2.5e7 also accepted); only used together with voltage. gain_curve/phase_curve: display the amplitude/phase frequency curve (settable only while the instrument is stopped).
Inputs: run, enable, points, ref_in, +8 more. Returns: result
configure_busA
Configure decoding bus BUS1..BUS4 (common + protocol settings).
protocol: PARallel|RS232|SPI|IIC|LIN|CAN|IIS|FLEXray|M1553 (:BUS:MODE).
Common settings (manual 3.4.1-3.4.9), every None argument is left unchanged: display: bus decoding display on/off format: event-table numeral system HEX|ASCii|DEC|BIN event: event-table display on/off (enable before :EEXPort/:DATA?) label: bus label display on/off - a bool per manual 3.4.5, not text position: bus vertical position, integer -250..250 threshold / threshold_type: per-source threshold in V, sent as ":BUS:THReshold ,", e.g. threshold=1.65, threshold_type="TX". Legal types: PAL|PALCLK|TX|RX|SCL|SDA|CS|CLK| MISO|MOSI|LIN|CAN|CANSub1|FLEX|1553|I2SClk|DATA|WS|CH1..CH4. Legal voltage range: +/-5 vertical divisions around the channel offset.
Typed protocol parameters, routed to the active protocol (if protocol= is omitted, the current bus mode is queried first): source: single line source, CAN|LIN|FLEXray|M1553 only baud: RS232 (1 bps..20 Mbps) | CAN (10 kbps..5 Mbps) | LIN (2.4 kbps..20 Mbps) | FLEXray (2.5/5/10 Mbps, discrete) dbits: RS232 (5..9) | SPI (4..32) parity: RS232 NONE|ODD|EVEN | LIN bool (include parity bit) polarity: POSitive|NEGative for RS232/PARallel/IIS, HIGH|LOW for SPI (cross-spellings are mapped) endian: MSB|LSB for RS232/SPI/IIS
Any other keyword goes through extra as {"": value}; KEY is the
SCPI sub-path validated against a whitelist from the manual, e.g.
RS232: {"RS232:TX": "CH1", "RS232:BAUD": 115200, "RS232:DBITs": 8}
IIC: {"IIC:SCLK:SOURce": "CH1", "IIC:SDA:SOURce": "CH2"}
SPI: {"SPI:SCLK:SOURce": "CH1", "SPI:MOSI:SOURce": "CH2"}
CAN: {"CAN:SOURce": "CH1", "CAN:BAUD": 500000}
Legal keywords per protocol (manual 3.4.10-3.4.18):
PARallel: BUS CLK SLOPe WIDTh BITX SOURce ENDian POLarity
RS232: TX RX POLarity PARity ENDian BAUD DBITs SBITs
IIC: SCLK:SOURce SDA:SOURce EXCHange ADDBits
SPI: SCLK:SOURce SCLK:SLOPe MISO:SOURce MOSI:SOURce POLarity
MISO:POLarity MOSI:POLarity DBITs ENDian MODE TIMeout:TIME
SS:SOURce SS:POLarity
CAN: SOURce STYPe BAUD FDBaud SPOint FDSPoint
LIN: SOURce STANdard BAUD PARity
FLEXray: SOURce BAUD SPOint STYPe CHANnel
IIS: SOURce:CLOCk SOURce:DATA SOURce:WSELect ALIGnment CLOCk:SLOPe
RWIDth RECewidth WSLow ENDian POLarity
M1553: SOURce
Protocol prefixes match case-insensitively (I2C->IIC, FLEX->FLEXray,
1553->M1553) and keywords accept unambiguous SCPI short forms.
Inputs: bus (required), baud, dbits, event, +12 more. Returns: result
configure_bus_canA
Set Bus to CAN/CAN-FD decoding and configure it (manual 3.4.14).
source: CAN line source CH1..CH4 or D0..D15 signal_type: TX|RX|CANH|CANL|DIFFerential (probe type, default CANH) baud: arbitration baud rate 10 kbps..5 Mbps in bps (default 1 Mbps) fd_baud: CAN-FD data-phase baud rate 1 Mbps..10 Mbps in bps sample_point: bit sample position 10..90 in % (default 80) fd_sample_point: CAN-FD data-phase sample position 10..90 in % display: enable the decoding bus
Inputs: bus (required), baud, source, display, +4 more. Returns: result
configure_bus_flexrayA
Set Bus to FlexRay decoding and configure it (manual 3.4.16).
source: FlexRay line source CH1..CH4 or D0..D15 baud: 2500000|5000000|10000000 bps (default 10000000) sample_point: bit sample position 10..90 in % (default 50) signal_type: BP|BM|RT probed signal (default BP) channel: FlexRay channel A|B (default A) display: enable the decoding bus
Inputs: bus (required), baud, source, channel, +3 more. Returns: result
configure_bus_iicA
Set Bus to I2C decoding and configure it (manual 3.4.12).
sclk / sda: clock (SCL) and data (SDA) line sources, CH1..CH4 or D0..D15 exchange: swap the clock and data channel sources addr_bits: slave address width 7|8|10 bits (default 7) display: enable the decoding bus
Inputs: bus (required), sda, sclk, display, +2 more. Returns: result
configure_bus_iisA
Set Bus to I2S decoding and configure it (manual 3.4.17).
clock / data / ws_select: serial clock, data and word-select (audio channel) line sources, each CH1..CH4 or D0..D15 alignment: IIS|RJ|LJ data alignment (default IIS) clk_slope: POSitive|NEGative clock edge sampled on word_width: word size 4..32 bits receive_width: receive width 4..32 bits ws_low: LEFT|RIGHt audio channel indicated by WS low endian: MSB|LSB bit order (default MSB) polarity: POSitive|NEGative data polarity display: enable the decoding bus
Inputs: bus (required), data, clock, endian, +8 more. Returns: result
configure_bus_linA
Set Bus to LIN decoding and configure it (manual 3.4.15).
source: LIN line source CH1..CH4 or D0..D15 standard: LIN bus version V1X|V2X|MIXed (default MIXed) baud: 2.4 kbps..20 Mbps in bps (default 9600) parity: include the parity bit in the decoded frames display: enable the decoding bus
Inputs: bus (required), baud, parity, source, +2 more. Returns: result
configure_bus_m1553A
Set Bus to MIL-STD-1553B decoding and configure it (manual 3.4.18).
source: 1553 bus line source CH1..CH4 or D0..D15 display: enable the decoding bus (Set the differential threshold via configure_bus(threshold=..., threshold_type='1553').)
Inputs: bus (required), source, display. Returns: result
configure_bus_parallelA
Set Bus to PARallel decoding and configure it (manual 3.4.10).
bus_source: data source D7D0|D15D8|D15D0|D0D7|D8D15|D0D15|CH1..CH4|USER (USER enables the per-bit sources below) clk: clock source CH1..CH4 or D0..D15, or OFF to sample on data change clk_slope: POSitive|NEGative|BOTH clock edge sampled on width: data width 1..16 (analog sources are limited to 1..4) bit / bit_source: select data bit 0..width-1, then its line source (BUS_source must be USER) endian: NEGative|POSitive (NEGative = inverted, manual default) polarity: NEGative|POSitive data polarity display: enable the decoding bus
Inputs: bus (required), bit, clk, width, +6 more. Returns: result
configure_bus_rs232A
Set Bus to RS232/UART decoding and configure it (manual 3.4.11).
tx / rx: line sources CH1..CH4 or D0..D15; rx also OFF (tx and rx cannot both be OFF) polarity: POSitive|NEGative logic sense (default NEGative idle-low) parity: NONE|ODD|EVEN endian: MSB|LSB bit order (default LSB) baud: 1 bps to 20 Mbps in bps (default 9600) dbits: 5|6|7|8|9 data bits (default 8) sbits: 1|1.5|2 stop bits (default 1) display: enable the decoding bus
Inputs: bus (required), rx, tx, baud, +6 more. Returns: result
configure_bus_spiA
Set Bus to SPI decoding and configure it (manual 3.4.13).
sclk: clock source CH1..CH4 or D0..D15 clk_slope: POSitive|NEGative clock edge sampled on miso / mosi: data line sources; each may be OFF but not both at once polarity: HIGH|LOW data polarity (high=1 / low=1) dbits: data width 4..32 bits (default 8) endian: MSB|LSB bit order (default MSB) mode: CS|TIMeout frame synchronization (default TIMeout) timeout_s: timeout frame gap in s, 8 ns..10 s (TIMeout mode only, must exceed the max clock pulse width) ss: chip-select line source CH1..CH4 or D0..D15 (CS mode only) ss_polarity: HIGH|LOW chip-select active level (CS mode only) display: enable the decoding bus
Inputs: bus (required), ss, miso, mode, +9 more. Returns: result
configure_laB
Logic analyzer digital channels D0..D15.
digital_channel like 'D3' plus channel_enable to turn one channel on/off and label to set its name; threshold: logic threshold voltage, -15 V .. +15 V, applied to the channel group selected by pod (1: D0-D7, 2: D8-D15); with a digital_channel the group is derived from it; without either, both groups are set (global threshold); active: currently selected digital channel D0..D15 (must be enabled); autosort: D0D15|D15D0 display order; size: SMALl|MEDium|LARGe waveform size (LARGe needs <= 8 channels on); pod + pod_display: enable/disable an entire channel group.
Inputs: pod, size, label, active, +6 more. Returns: result
configure_maskB
Pass/fail mask test.
source: CHANnel1..CHANnel4 (a disabled channel is enabled automatically); operate: RUN|STOP (enable the test before running it); x_adjust: horizontal mask tolerance, 0.01..2 div; y_adjust: vertical mask tolerance, 0.04..2 div; create_from_source: create the mask from the current source waveform (test must be enabled and stopped); reset: reset the passed/failed/total frame counters; output_enable: pulse the rear-panel AUX OUT connector on mask events; output_event: FAIL|PASS event that triggers the AUX OUT pulse; output_pulse_s: AUX OUT pulse width, 100 ns .. 10 ms.
Inputs: reset, enable, source, operate, +6 more. Returns: result
configure_mathA
Configure math channel MATH1..MATH4 (manual 3.16). Only given parameters are changed; all validation happens before anything is sent.
operator: ADD|SUBTract|MULTiply|DIVision|AND|OR|XOR|NOT|FFT|INTG|DIFF| SQRT|LG|LN|EXP|ABS|LPASs|HPASs|BPASs|BSTop|AXB source1/source2: arithmetic/function/filter sources — CH1..CH4, REF1..REF10 or a lower-numbered MATH channel (MATH1..MATH) scale/offset: vertical scale/offset of the math result (unit follows the operator; invalid for logic and FFT operators) invert: invert the math waveform (not for FFT/logic) lsource1/lsource2: logic operation sources — D0..D15 or CH1..CH4 grid: FULL|HALF|NONE math window grid; expand: GND|CENTer vertical expansion reference; wavetype: MAIN|ZOOM (ZOOM needs zoom enabled) fft_source: CH1..CH4 or MATH1..MATH3 fft_window: RECTangle|BLACkman|HANNing|HAMMing|FLATtop|TRIangle fft_unit: VRMS|DB; fft_mode: NORMal|AVERage|MAXHold fft_avg_count: FFT average count 2..1000 (AVERage mode) fft_scale/fft_offset: spectrum vertical scale/offset (2.0 dB / 1 mVrms steps default; range depends on fft_unit) fft_hscale_hz: frequency span 10 Hz..2 GHz; fft_hcenter_hz: center frequency 5 Hz..2 GHz (span and center influence each other) fft_start_hz/fft_end_hz: 0..2 GHz; end must exceed start by >10 Hz fft_search_enable: FFT peak search on/off; fft_search_num: 1..15 peaks; fft_search_threshold/fft_search_excursion: peak detection levels (excursion >= 0, in dB); fft_search_order: AMPorder|FREQorder filter_type: LPASs|HPASs|BPASs|BSTop; filter_w1/filter_w2: cutoff frequencies in Hz (band types need both, W1 < W2; range depends on the screen sample rate) sensitivity: logic operation sensitivity in div (0.1..1.0) distance: differentiation smoothing window 5..10000 points threshold1..threshold4: logic thresholds of CH1..CH4 in V label_show: show the math waveform label; dismode: True = show the math waveform in the main view instead of the math window reset: auto-fit the result's vertical scale (:MATH:RESet) extra: {"KEYWORD": value} passthrough for :MATH keywords documented in section 3.16 (e.g. {"FFT:SEARch:NUM": 10}); unknown keywords are rejected; RESet takes no value (pass None).
Inputs: grid, extra, index, reset, +38 more. Returns: result
configure_measure_amplitudeB
Amplitude measurement method (:MEASure:AMP tree).
type: overall measurement type, THReshold | RANGe | AMPMethod (AMPMethod enables this tree); method: AUTO | MANual amplitude method; top/base: top/base value type for the manual method, HISTogram | MAXMin.
Inputs: top, base, type, method. Returns: result
configure_measure_regionA
Measurement range (gating region) configuration.
area: MAIN | ZOOM (needs delayed sweep) | CURSor (custom region); type: measurement type THReshold | RANGe | AMPMethod; cursor_ax/cursor_bx: cursor-region boundaries in s (for area=CURSor); link_cursors: tie region cursor A and B together (:MEASure:CREGion:CABX).
Inputs: area, type, cursor_ax, cursor_bx, +1 more. Returns: result
configure_measure_setupB
General measurement configuration.
source: default measurement source (CH1..CH4 / MATH1..4 / D0..D15); all_measure_source: All-Measure source (CH1..CH4, or OFF to disable); indicator: measurement auto-cursor on/off; category: measure menu category, 0=vertical, 1=horizontal, 2=other; delete_items: clear all enabled measurement items (:MEASure:DELete).
Inputs: source, category, indicator, delete_items, +1 more. Returns: result
configure_quickA
Configure the QUICK button operation (not the quick measurement readout -- use measure_quick for that).
operation: SIMage (save screen image) | SWAVe (save waveform) | SSETup (save setup) | AMEasure (all measure) | SRESet (statistics reset) | RECord (waveform record) | SSAVe (save group). Short forms (SIM, SWAV, SSET, AME, SRES, REC, SSAV) are accepted.
Inputs: operation. Returns: result
configure_recordA
Waveform recorder and playback.
Recording: operate RUN|STOP; frames: number of frames to record (>= 1, frames_max=True records the maximum); interval_s: frame interval 10 ns .. 1 s; prompt: beep when recording completes. Playback: playback_operate RUN|STOP; playback_current / playback_start / playback_end: frame numbers (>= 1); playback_interval_s: 1 ms .. 1 s; playback_mode REPeat|SINGle; playback_direction FORWard|BACKward; playback_step BACK|NEXT steps one frame manually; play_from FFIRst|FEND restarts manual playback from an end. The documented legacy duplicates (:RECord:STARt, :RECord:FRAMes, :RECord:CURRent, :RECord:PLAY) stay reachable via extra, e.g. {"STARt": 1}; unknown keywords raise ValueError.
Inputs: extra, enable, frames, prompt, +12 more. Returns: result
configure_referenceA
Reference waveform REF1..REF10 (manual 3.20).
source: D0..D15, CH1..CH4 or MATH1..MATH4 (must currently be enabled).
vscale/voffset: vertical scale/offset of the reference trace in V (only
available once a waveform has been saved into the slot; the scale range
depends on the probe ratio and input impedance).
color: GRAY|GREen|BLUE|RED|ORANge.
label: per-slot label text; label_enable: label display for ALL
reference slots (global flag).
save_current captures the source channel's current waveform into the
reference slot (:REFerence:CURRent + :REFerence:SAVE, source must be
given); reset restores the default scale/offset.
There is no reference save-to-file / load-from-file command in the
:REFerence subsystem — exporting a trace to disk goes through
get_waveform.
Inputs: ref (required), color, label, reset, +5 more. Returns: result
configure_saveA
Image/file saving options.
invert: invert colors when saving images; color: COLor|GRAY; image_format: PNG|BMP|JPG; header: print model + date banner on images; overlap: overwrite same-name files; prefix: default filename prefix (max 16 chars, no extension); pathname: default save directory on the instrument, e.g. "C:/new".
extra: only documented :SAVE option keywords, e.g. {"PREFix": "Rigol"}.
Inputs: color, extra, header, invert, +4 more. Returns: result
configure_searchA
Event search on the acquired waveform (manual 3.22).
mode: EDGE|PULSe (only these two search types are documented). Edge search: edge_slope POSitive|NEGative|EITHer, edge_source CHANnel1..CHANnel4, edge_threshold in V. Pulse search: pulse_polarity POSitive|NEGative, pulse_qualifier GREater|LESS|GLESs, pulse_source CHANnel1..CHANnel4, pulse_uwidth_s / pulse_lwidth_s 800 ps .. 10 s, pulse_threshold in V. Documented keywords may also be passed via extra, e.g. {"EDGE:SLOPe": "NEGative"}; unknown keywords raise ValueError.
Inputs: mode, extra, enable, edge_slope, +8 more. Returns: result
configure_smbB
Configure SMB (Windows share) file saving.
server_path: "\192.168.1.5\Share" (IP address + English-letters share name); username/password: printable ASCII, no Chinese characters; autoconnect: reconnect the share at boot.
Inputs: password, username, autoconnect, server_path. Returns: result
connectC
Connect to the oscilloscope.
resource defaults to MHO98_RESOURCE env or the built-in default
(TCPIP0::169.254.112.67::5555::SOCKET). USB example:
USB0::0x1AB3::0x****::DSN********::INSTR
Inputs: resource.
disconnectB
Close the current instrument connection.
Inputs: no named parameters.
export_bus_on_instrumentC
Export the event table to a CSV on the INSTRUMENT's own storage (USB stick), e.g. path='C:/123.csv' or 'E:/decode.csv'.
Inputs: bus (required), path (required). Returns: result
export_waveform_csvC
Convenience wrapper: full-memory CSV export (stops the instrument).
Inputs: mode, stop, start, source, +1 more. Returns: result
get_acquireA
Read back acquisition settings incl. current sample rate.
Inputs: no named parameters. Returns: result
get_autoset_optionsA
Read back the AUTO (autoset) option states (all return 0 or 1).
Inputs: no named parameters. Returns: result
get_awg_configA
Read back the core generator channel configuration (raw SCPI strings).
Covers output state, function, frequency, amplitude, offset, phase and impedance; use get_awg_full_config() for every :SOURce readback including period, high/low levels, duty, symmetry, arb path and modulation.
Inputs: channel (required). Returns: result
get_awg_full_configB
Read back every generator channel setting (manual 3.25.1 - 3.25.25).
Returns engineered values: booleans for states, floats (Hz, s, V, degrees, percent) for numerics and short-form strings for enums (e.g. function "SQU", modulation waveform "TRI"). Includes the loaded arbitrary waveform path and the complete AM/FM/PM modulation configuration.
Inputs: channel (required). Returns: result
get_bode_configA
Read back the full Bode plot configuration (manual 3.5.1 - 3.5.11).
voltage_range selects which frequency range's amplitude is queried by :BODeplot:VOLTage? (ALL|10|100|1K|10K|100K|1M|10M|25M or numeric forms). Returns engineered values: booleans for enables/run state, floats in Hz/V, int points per decade; ref_in/ref_out come back in short form (CHAN1..4).
Inputs: voltage_range. Returns: result
get_bus_configA
Read back the decoding bus configuration.
Default (no extra arguments): queries :BUS:MODE?, DISPlay? and LABel? only. Any of full=True / protocol= / thresholds= additionally reads FORMat/EVENt/POSition; full=True or protocol= also queries every per-protocol keyword the manual defines for the decoding type (returned under 'protocol_config', keyed by the SCPI keyword, e.g. 'RS232:BAUD'); thresholds= adds per-source threshold voltages.
protocol: explicitly select which protocol keyword set to query; by default the set follows the bus mode reported by the instrument. thresholds: threshold source types to query, e.g. ["TX","RX"] or ["SCL","SDA"] (manual 3.4.9) -> {type: volts string}.
Inputs: bus (required), full, protocol, thresholds. Returns: result
get_channelC
Read back the configuration of an analog channel.
Inputs: channel (required). Returns: result
get_channel_fullA
Read back the complete configuration of an analog channel.
Adds the vernier (fine adjustment), delay calibration (TCALibrate, in s) and label visibility queries to get_channel().
Inputs: channel (required). Returns: result
get_cursor_valuesA
Read cursor positions and deltas for the active cursor mode.
Manual-mode readings (ax, bx, ay, by, x_delta, 1/x_delta in Hz, y_delta) are always returned; track=True additionally reads the track-mode readings (track_* keys) and the track axis. Readings unavailable in the current mode come back as "<error ...>" strings.
Inputs: track. Returns: result
get_cursor_xy_valuesA
Read XY-mode cursor positions and deltas (all values in V).
Only meaningful with :CURSor:MODE XY and the timebase in XY mode; unavailable readings come back as "<error ...>" strings.
Inputs: no named parameters. Returns: result
get_datetimeA
Read the instrument clock (:SYSTem:DATE? and :SYSTem:TIME?), returned as date 'YYYY-MM-DD', time 'HH:MM:SS' and a combined string.
Inputs: no named parameters. Returns: result
get_displayA
Read back the display settings.
type (VECT), persistence (MIN..10 or INF), waveform/grid/cursor brightness in percent, grid (FULL|HALF|NONE), and the ruler/color-grade/waveform-freeze states (0 or 1).
Inputs: no named parameters. Returns: result
get_errorsB
Read the instrument error queue (:SYSTem:ERRor?). Returns up to 20 entries.
Inputs: clear. Returns: result
get_histogram_configB
Read back the histogram configuration (manual 3.11.1-3.11.8).
Inputs: no named parameters. Returns: result
get_idnA
Query instrument identity (*IDN?): manufacturer, model, serial, firmware.
Inputs: no named parameters. Returns: result
get_ieee488_statusA
Read the IEEE488.2 status registers (*ESR?, *STB?) and their enable masks (*ESE?, *SRE?), with named-bit decoding.
*ESR? reads-and-clears the standard event register; *STB? clears the status byte. Bits follow manual tables 3.153/3.154.
Inputs: no named parameters. Returns: result
get_keyboard_checkA
Front-panel key/knob self-test results (:SYSTem:KEYBoard:CHECk?).
Only meaningful after running the key test on the instrument (Utility > Self Check > Key Test); untested keys report false. Returns the parsed result map plus the raw string.
Inputs: no named parameters. Returns: result
get_la_configB
Read back the logic analyzer configuration (manual 3.13): enable, active channel, autosort, size, per-group display state and threshold. With digital_channel (D0..D15), also reads that channel's on/off state and label.
Inputs: digital_channel. Returns: result
get_lan_configA
Read the full LAN configuration.
Returns IP address, subnet mask, gateway, DNS, DHCP server, MAC, the DHCP/Auto-IP/Static(mANual)/mDNS mode switches (as booleans), hostname, description, link status and the VISA resource string.
visa_type: USB|LXI|SOCKet — address type for :LAN:VISA? (default LXI). Link status values: UNLINK, CONNECTED, INIT, IPCONFLICT, BUSY, CONFIGURED, DHCPFAILED, INVALIDIP, IPLOSE.
Inputs: visa_type. Returns: result
get_mask_configB
Read back the pass/fail test configuration (manual 3.15).
Inputs: no named parameters. Returns: result
get_mask_resultB
Mask test counters: failed, passed and total frame counts.
Inputs: no named parameters. Returns: result
get_math_configC
Read back the configuration of a math channel.
Inputs: index. Returns: result
get_math_config_fullA
Read back the complete configuration of a math channel.
get_math_config() plus every other queryable :MATH parameter: invert, grid/expand/wavetype, logic sources, the whole FFT block (source, window, unit, mode, average count, scale/offset, frequency span/center, peak search settings), filter type and cutoffs, logic sensitivity/distance/ thresholds, label display, display mode and the math window title. Numeric replies are converted (ints/floats).
Inputs: index. Returns: result
get_math_fft_peaksA
Query the FFT peak search results table (:MATH:FFT:SEARch:RES?, manual 3.16.30). Requires the peak search to be enabled first (configure_math fft_search_enable=True).
Returns up to 15 rows — rank, frequency (Hz when the unit is recognized) and amplitude with its unit as displayed by the instrument — plus the raw reply. The table is small enough to return inline (not sample data).
Inputs: index. Returns: result
get_math_waveformA
Acquire the computed waveform of math channel MATH1..MATH4 to a file.
There is no :MATH:DATA? command on this model — math data is read through :WAVeform:SOURce MATH + :WAVeform:DATA? (manual 3.28.1). Firmware quirk (verified on 00.01.00): MATH sources are only readable in NORMal waveform mode, so this wrapper always uses NORMal. Samples go to disk exactly like get_waveform; only statistics come back inline.
Inputs: fmt, index, filename, save_format. Returns: result
get_option_statusA
Query software-option installation (:SYSTem:OPTion:STATus? or, with valid=True, :SYSTem:OPTion:VALid?).
WARNING: on firmware 00.01.00 BOTH queries never answer and hang the
connection. The tool therefore does nothing unless opt_in=True is passed
explicitly; the default call returns a skipped marker without touching
the instrument.
option_type: BND|AFG100|AFG50|AUDio|CAN-FD|FLEX|AERO|RLU-05|BWU03T05| BWU03T08|BWU05T08. Option install/uninstall commands exist but are deliberately not exposed (licensed, destructive).
Inputs: option_type (required), valid, opt_in. Returns: result
get_record_statusA
Read back waveform record/playback state (manual 3.19): enables, operate states, frame counts and limits, intervals, playback settings and the current frame number and its timestamp.
Inputs: no named parameters. Returns: result
get_reference_configA
Read back the configuration of reference channel REF1..REF10 (manual 3.20): source, vertical scale/offset (V), color, label, plus the global reference label-display flag.
Inputs: ref (required). Returns: result
get_save_configA
Read back all :SAVE options (image invert/color/format/header, overwrite mode, filename prefix, storage path, storage status).
Inputs: no named parameters. Returns: result
get_save_statusA
Query the storage state (:SAVE:STATus?). Returns done=True when the previous saving operation has completed (firmware returns 1).
Inputs: no named parameters. Returns: result
get_screenshotB
Capture the oscilloscope screen and save it to a local file.
image_format: PNG|BMP|JPG. Returns the file path and size; the image itself is not inlined.
Inputs: filename, image_format. Returns: result
get_screenshot_dataA
Fetch the current screen bitmap via :SAVE:IMAGe:DATA? and write it to a LOCAL file under MHO98_DATA_DIR (alternative to the display subsystem's :DISPlay:DATA? screenshot). Only path + size are returned, never the blob.
The image honors the :SAVE:IMAGe:* options (color/invert/header/format,
see configure_save). Format is sniffed from the magic bytes.
Inputs: filename. Returns: result
get_search_configB
Read back the search configuration and event counters (manual 3.22).
Inputs: no named parameters. Returns: result
get_search_event_timeB
Time value of a line in the search mark table (:SEARch:VALue?).
line: 1-based line number of the mark table; returns the event time.
Inputs: line (required). Returns: result
get_smb_configA
Read back the SMB share configuration: server path, user name, password, auto-connect-at-boot flag and the live connection state.
Inputs: no named parameters. Returns: result
get_smb_statusA
SMB share connection state (:SAVe:SMB:CONState?). connected=True when 1.
Inputs: no named parameters. Returns: result
get_statusA
One-stop instrument snapshot: identity, run state, trigger status, sample rate, memory depth, acquisition settings, enabled channels, LAN status and pending errors.
Inputs: no named parameters. Returns: result
get_system_configB
Read back every writable :SYSTem setting (section 3.24): beeper, language, power-on recall mode, front-panel lock, low-power mode, on-screen clock, AUX OUT type, power status and AUTO-key enable.
Inputs: no named parameters. Returns: result
get_system_infoA
System info: firmware, installed modules/options, hardware layout, LAN parameters.
Note: :SYSTem:OPTion:STATus? / :OPTion:VALid? hang on firmware 00.01.00
and are therefore skipped (see get_option_status for an opt-in probe).
Inputs: no named parameters. Returns: result
get_timebaseC
Read back the horizontal system configuration.
Inputs: no named parameters. Returns: result
get_timebase_fullA
Read back the complete horizontal system configuration.
Adds the horizontal reference mode/position, vernier and XY-mode (enable, X/Y sources, grid) queries to get_timebase().
Inputs: no named parameters. Returns: result
get_trigger_commonD
Inputs: no named parameters. Returns: result
get_trigger_configA
Read back the full configuration of one trigger type (all its queries).
trigger_type: any :TRIGger:MODE value (EDGE, PULSe, SLOPe, VIDeo, PATTern, DURation, TIMeout, RUNT, WINDow, DELay, SETup, NEDGe, RS232, IIC, SPI, CAN, LIN, FLEXray, IIS, M1553) or COMMON for the trigger-wide settings (mode/sweep/holdoff/coupling/nreject/status/position). level_source: channel used for the PATTern/DURation per-channel level query (':LEVel? ' per the manual), e.g. 'CH2'.
Inputs: level_source, trigger_type. Returns: result
get_trigger_positionA
Trigger position in the internal memory (:TRIGger:POSition?, query-only).
Inputs: no named parameters. Returns: result
get_trigger_statusB
Trigger status: TD = triggered, WAIT = waiting, AUTO = auto.
Inputs: no named parameters. Returns: result
get_waveformA
Acquire waveform data and SAVE it to a local file.
Returns metadata (preamble + statistics) and the file path only — sample arrays are never inlined, to protect the caller's context window.
source: CH1..CH4 or MATH1..MATH4 (MATH only in NORMal mode). mode: NORMal (screen, 1000 pts) | MAXimum | RAW (full memory; the instrument is stopped first). fmt: BYTE|WORD|ASCII. start/stop: 1-based inclusive point range (RAW/MAX). points: alternative window selector — number of points to read (:WAVeform:POINts, manual 3.28.4); when given, the RAW full-memory start/stop default is skipped and start/stop are only sent if explicitly provided. save_format: csv | npy (npy recommended for RAW ≥ 1M points; CSV is refused above max_csv_points=2M unless force_csv=True — a 50M-point CSV would be ~2 GB of text). Parse the file afterwards with your own protocol scripts.
Inputs: fmt, mode, stop, start, +7 more. Returns: result
get_waveform_preambleA
Query the 10 waveform preamble parameters of a source.
Returns format, type, points, count, xincrement, xorigin, xreference, yincrement, yorigin, yreference (with engineering interpretation). apply=False only queries without touching source/mode settings. source (when given): CH1..CH4 or MATH1..MATH4; mode: NORMal|MAXimum|RAW (MATH sources only support NORMal mode).
Inputs: mode, apply, source. Returns: result
get_waveform_setupA
Read back the current :WAVeform read-out configuration (manual 3.28).
Queries :WAVeform:SOURce?/:MODE?/:FORMat?/:POINts?/:STARt?/:STOP? and the six per-axis scaling queries (:XINCrement?/:XORigin?/:XREFerence?/ :YINCrement?/:YORigin?/:YREFerence?) as engineered values (ints/floats). The preamble (get_waveform_preamble) returns the same axis data in a single query.
Inputs: no named parameters. Returns: result
list_resourcesA
List VISA resources visible on this host.
Note: raw-socket instruments are not discoverable; the MHO98 must be
addressed by its resource string (see connect).
Inputs: no named parameters.
load_mask_on_instrumentA
Load a .pf mask file from the instrument's own storage (:LOAD:MASK ).
Inputs: path (required). Returns: result
load_setupB
Load a setup file previously written by save_setup into the instrument.
Inputs: filename (required). Returns: result
load_setup_on_instrumentB
Load a .stp setup file from the instrument's own storage (:LOAD:SETup ).
Inputs: path (required). Returns: result
measure_batchC
Measure multiple items on one source, returned as a dict.
Inputs: items (required), source, source2. Returns: result
measure_itemA
Measure one of the 44 items and return its current value.
Delay/phase items (RRDelay..FFPHase) need source and source2. source: CH1..CH4 / MATH1..4 / D0..D15. show_on_screen=True additionally puts the item on the scope display. Items: VMAX, VMIN, VPP, VTOP, VBASe, VAMP, VAVG, VRMS, OVERshoot, PREShoot, MARea, MPARea, PERiod, FREQuency, RTIMe, FTIMe, PWIDth, NWIDth, PDUTy, NDUTy, TVMAX, TVMIN, PSLewrate, NSLewrate, VUPPer, VMID, VLOWer, PVRMs, PPULses, NPULses, PEDGes, NEDGes, RRDelay, RFDelay, FRDelay, FFDelay, RRPHase, RFPHase, FRPHase, FFPHase, ACRMs.
Inputs: item (required), source, source2, show_on_screen. Returns: result
measure_quickC
Read the common quick set on one channel: VPP VMAX VMIN VAVG VRMS PERiod FREQuency RTIMe FTIMe PWIDth PDUTy.
Inputs: source. Returns: result
measure_statistics_itemB
Read one statistic of a measurement item, or enable item statistics.
statistic: MAXimum|MINimum|CURRent|AVERages|DEViation|CNT (short forms ok). source/source2: CH1..CH4 / MATH1..4 / D0..D15 (source2 only for the delay/phase items). enable=True first sends the write form (:MEASure:STATistic:ITEM) to turn on statistics for the item.
Inputs: item (required), enable, source, source2, +1 more. Returns: result
read_bus_dataA
Read the decoding event table (:BUS:DATA?).
The full table is saved to a CSV file (ready for protocol-analysis scripts); only a short preview and row count are returned inline. Requires the bus to be enabled with a decodable signal on its sources.
Inputs: bus (required), save_csv, preview_chars. Returns: result
read_counterB
Hardware frequency counter state.
Returns the current value, enable, source, mode (FREQ/PER/TOT) and resolution (digits 3-6). totalize=True additionally reads the counter statistics switch (:COUNter:TOTalize:ENABle?).
Inputs: totalize. Returns: result
read_dvmA
Digital multimeter current reading (DVM option).
:DVM:CURRent? hangs on the instrument while the DVM is disabled, so the reading is only requested when the DVM is on.
Inputs: no named parameters. Returns: result
read_histogram_statsB
Histogram analysis statistics (Sum, Peaks, Max, Min, Pk_Pk, Mean, Median, Mode, Bin width, Sigma, meanPlusSigma/2/3 ...).
Queries :HISTogram:STATistics:RESult? (manual 3.11.9) and falls back to the measurement-histogram variant :MEASure:HISTogram:STATistics:RESult? (manual 3.17.32). Values are parsed into a dict; 'raw' keeps the reply.
Inputs: no named parameters. Returns: result
reboot_systemA
Reset the instrument to power-on state (:SYSTem:RESet).
This restarts the scope operating system: the current configuration is
lost and the LXI/USB connection may drop for ~30 s. Not the same as
reset (*RST), which only restores default settings.
Inputs: no named parameters. Returns: result
resetA
Send *RST: restore default instrument settings.
Inputs: no named parameters. Returns: result
save_image_on_instrumentA
Store the current screen image on the instrument's own storage (:SAVE:IMAGe ).
path: e.g. "C:/shot.png" (internal disk) or "D:/shot.bmp" (USB storage). Suffix must be .png, .bmp or .jpg; filename max 26 characters.
Inputs: path (required). Returns: result
save_mask_on_instrumentA
Store the pass/fail mask as a .pf file on the instrument's own storage
(:SAVE:MASK ). Reload it with load_mask_on_instrument.
Inputs: path (required). Returns: result
save_memory_waveform_on_instrumentB
Store the full-memory waveform on the instrument's own storage (:SAVE:MEMory:WAVeform ). Suffix .bin, .csv or .wfm; filename max 26 characters.
Inputs: path (required). Returns: result
save_setupB
Save the complete instrument setup (:SYSTem:SETup?) to a local file.
Inputs: filename. Returns: result
save_setup_on_instrumentA
Store the current setup as a .stp file on the instrument's own storage (:SAVE:SETup ). Filename max 26 characters.
Inputs: path (required). Returns: result
save_waveform_on_instrumentA
Store the screen waveform on the instrument's own storage (:SAVE:WAVeform ). Suffix .bin or .csv; filename max 26 characters.
Inputs: path (required). Returns: result
scpiA
Escape hatch: send any SCPI command to the instrument.
Commands containing '?' are queried and the text/binary answer returned. Binary answers are saved to a file (never inlined into the response).
Inputs: command (required), expect_binary. Returns: result
self_testA
Run instrument self-test (*TST?). 0 = pass, 1 = failure (check errors).
Inputs: no named parameters. Returns: result
set_acquireA
Acquisition system.
type: NORMal|PEAK|AVERages|HRESolution memory_depth: AUTO|1k|10k|100k|1M|10M|25M|50M|100M|125M|200M|250M|500M (numeric equivalents like 1e6 or 25000000 are normalized to the mnemonic; max 500 Mpts single-channel, 250 Mpts half, 125 Mpts full) averages: 2..65536, power of two (AVERages type only; the instrument rounds non-power-of-two values down, this wrapper rejects them) bits: 12|14|16 (14|16 in HRESolution mode, 12 in the other modes)
Inputs: bits, type, averages, memory_depth. Returns: result
set_autoset_optionsA
Configure the AUTO (autoset) options WITHOUT executing an autoset.
Same parameters as autoscale(), plus: enable: master on/off of the AUTO function (:AUToset:ENAble, 3.2.7); False disables :AUToset just like lock_timebase=True
Inputs: enable, peak_search, view_overlap, keep_coupling, +2 more. Returns: result
set_awg_outputC
Turn generator channel output ON/OFF.
Inputs: state (required), channel (required). Returns: result
set_channelA
Configure an analog channel (CH1..CH4). Only given parameters are changed.
scale: V/div (1 mV..10 V/div at 1 MΩ/1X, 200 µV..1 V/div at 50 Ω/1X; range scales with the probe ratio) offset: vertical offset in V (range depends on scale and impedance) coupling: AC|DC|GND probe: attenuation ratio 0.001..50000 (discrete 1-2-5 steps plus 15-series values; custom ratios allowed) bw_limit: OFF|ON|20M|250M impedance: OMEG (1 MΩ) | FIFTy (50 Ω); accepts 1M/50 aliases position: vertical position (bias voltage) in V, per manual 3.6.14 label: channel label text; show_label: display the label vernier: fine adjustment of the vertical scale units: WATT|AMPere|VOLTage|UNKNown tcal: delay calibration time in s, -100 ns..100 ns
Inputs: channel (required), tcal, label, probe, +11 more. Returns: result
set_counterA
Configure the hardware counter.
mode: FREQuency|PERiod|TOTalize (short forms FREQ/PER/TOT ok); digits: resolution, integer 3 to 6 (Period/Frequency modes only); source: CH1..CH4 or D0..D15; totalize_enable: counter statistics switch (Period/Frequency only); totalize_clear: clear the totalize count (Totalize mode only).
Inputs: mode, digits, enable, source, +2 more. Returns: result
set_cursorB
Configure cursors.
mode: OFF|MANual|TRACk|XY (XY requires timebase mode XY); cursor_type (manual mode): TIME (X cursor) | AMPLitude (Y cursor); source/source2: manual source and track source 1/2 (CH1..CH4 / MATH1..4 / NONE); ax/bx: cursor A/B horizontal positions in s; ay/by: vertical in V (applied to both the manual and the track cursors); indicator: cursor measurement indicator on/off; tunit: manual horizontal unit SECond; vunit: manual vertical unit SOURce; track_mode: track axis X|Y; xy_ax/xy_bx/xy_ay/xy_by: XY-mode cursor positions in V.
Inputs: ax, ay, bx, by, +12 more. Returns: result
set_datetimeA
Set the instrument clock and read it back (:SYSTem:DATE / :SYSTem:TIME).
datetime: 'YYYY-MM-DD hh:mm:ss' (24-hour). Raises ValueError on bad format or out-of-range fields (year 1900..2100).
Inputs: datetime (required). Returns: result
set_displayA
Display settings.
type: DOTS|VECTors (the manual documents VECTors for this model) persistence: MIN|0.1|0.2|0.5|1|2|5|10|INFinite seconds ('1S'/'1.0' are normalized to plain seconds — the firmware rejects suffixed forms) waveform_brightness: 1..100 (percent) grid_brightness: 0..100; cursor_brightness: 0..100 grid: FULL|HALF|NONE ('OFF' accepted as an alias of NONE) clear: clear all waveforms from the screen rulers: show the scale rulers track_ruler: move the scale ruler to track the waveform coordinate color_grade: color grade display (acquisition-probability coloring) waveform_hold: freeze the displayed waveform
Inputs: grid, type, clear, rulers, +7 more. Returns: result
set_dvmB
Configure DVM. source: CH1..CH4; mode: ACRMs|DC|DCRMs (volts).
The AC and DCRM spellings are accepted as aliases of ACRMs/DCRMs.
Inputs: mode, enable, source. Returns: result
set_histogramB
Histogram analysis display and statistics.
type: HORIzontal|VERTical; source: CHANnel1..CHANnel4; height: histogram height, 1..4 divisions; range_left/right: horizontal display limits in s (left < right); range_top/bottom: vertical display limits in V (bottom < top); reset: clear the histogram statistics; save_csv: save the histogram data to a file on the instrument (e.g. 'C:/hist.csv'); boundary: sigma boundary shown (u1S|u2S|u3S) - not documented in the current Programming Guide, kept for backward compatibility.
Inputs: type, reset, enable, height, +7 more. Returns: result
set_ieee488_enableA
Set IEEE488.2 enable registers (*ESE, *SRE) and optionally arm *OPC.
event_enable: bit sum (0..255) for the standard event register
(OPC=1, QYE=4, DDE=8, EXE=16, CME=32, PON=128 — table 3.153).
service_enable: bit sum (0..255) for the status byte register
(ERR queue=4, QSD=8, MAV=16, SES=32, MSS=64, OSR=128 — table 3.154).
signal_operation_complete: send *OPC so bit 0 of *ESR latches when all
pending operations finish (poll with get_ieee488_status).
Inputs: event_enable, service_enable, signal_operation_complete. Returns: result
set_lanA
Configure the LAN interface (section 3.14).
ip/gateway/dns: dotted-quad, first octet 0..223 (not 127), others 0..255; mask: dotted-quad with every octet 0..255. Static addresses only apply when DHCP and Auto IP are off and manual (static) mode is on. The three IP modes cannot all be off at once (firmware rule). dhcp/auto_ip/manual/mdns: booleans; hostname/description: printable ASCII. apply: send :LAN:APPLy afterwards to activate all pending LAN settings.
extra: only documented :LAN keywords are accepted, e.g. {"HOST:NAME": "scope1"} → :LAN:HOST:NAME scope1.
Inputs: ip, dns, dhcp, mask, +8 more. Returns: result
set_measure_counterA
Frequency counter addressed through the :MEASure command tree.
Same counter as set_counter, but via :MEASure:COUNter. enable: counter on/off; source: CH1..CH4 or D0..D15. The counter value is read back via :MEASure:COUNter:VALue? when the counter is enabled.
Inputs: enable, source. Returns: result
set_measure_histogramA
Measurement histogram enable (statistics of measurement items).
Distinct from the waveform histogram (:HISTogram, analysis module). The statistics themselves are read with read_histogram_stats, which queries :MEASure:HISTogram:STATistics:RESult?.
Inputs: enable. Returns: result
set_measure_sources_abA
Set Source A / Source B used by phase and delay measurements.
Source A is written to both :MEASure:SETup:PSA and :MEASure:SETup:DSA (identical functions per the manual); Source B likewise to PSB/DSB. Sources: CH1..CH4 / MATH1..4 / D0..D15. Returns the read-back of all four.
Inputs: source_a, source_b. Returns: result
set_measure_statisticsC
Control measurement statistics (mean/min/max/... over N acquisitions).
count: statistics count, integer 2 to 100000; reset: clear history data.
Inputs: count, reset, enable. Returns: result
set_measure_thresholdsA
Measurement thresholds (used for rise time, delay, phase, ...).
source: threshold source CH1..CH4 / MATH1..4 (selected via :MEASure:THReshold:SOURce); threshold_type: PERCent (10-90 etc.) | ABSolute; upper/middle/lower: threshold upper/middle/lower level — percent when the type is PERCent, volts when ABSolute (sent as :MEASure:SETup:MAX/MID/MIN); reset_defaults=True restores the default threshold levels (:MEASure:THReshold:DEFault).
Inputs: source (required), lower, upper, middle, +2 more. Returns: result
set_run_stateA
Run control.
state: RUN | STOP | SINGLE (single acquisition, arm) | FORCE (force trigger now) | CLEAR (clear screen) hotkeys: True routes RUN|STOP|SINGLE through :TIMebase:HOTKeys, the front-panel hotkey variant of the same commands (3.26.10); FORCE and CLEAR have no hotkey equivalent.
Inputs: state (required), hotkeys. Returns: result
set_systemA
Misc system settings (:SYSTem section 3.24).
language: SCHinese|TCHinese|KORean|JAPanese|ENGLish|GERMan|PORTuguese| POLish|FRENch|RUSSian|SPAN|THAI|INDonesian (short readback codes like ENGL or SCH are accepted as aliases) power_on: LATest|DEFault (config recalled at power-on) key_lock: lock front panel; low_power: 1 W standby datetime: 'YYYY-MM-DD hh:mm:ss' sets scope clock show_time: display the system time on screen (:SYSTem:STIMe) aux_output: TOUT|PFAil — signal on the rear [AUX OUT] connector power_status: DEFault|OPEN — OPEN boots directly after power application auto_key: enable/disable the front-panel AUTO key (:SYSTem:AUToscale)
Inputs: beeper, auto_key, datetime, key_lock, +6 more. Returns: result
set_timebaseB
Horizontal system. scale: s/div of MAIN timebase; offset: trigger position shift in s; mode: MAIN|XY|ROLL; delayed timebase via delay_* parameters.
roll: auto-ROLL mode (enter ROLL automatically at >= 50 ms/div) horizontal_reference_mode: CENTer|LB|RB|TRIG|USER (expansion reference used when the timebase changes) horizontal_reference_position: user-defined reference position, integer -500 (left edge) .. 500 (right edge) vernier: fine adjustment of the horizontal scale xy_enable: XY mode on/off (alternative to mode="XY") xy_x/xy_y: XY source channels, 1..4 (accepts 3, 'CH3' or 'CHANnel3') xy_grid: FULL|HALF|NONE grid of the XY display
Inputs: mode, roll, xy_x, xy_y, +10 more. Returns: result
set_trigger_commonA
Trigger-wide settings (apply to the current trigger type).
mode: EDGE|PULSe|SLOPe|VIDeo|PATTern|DURation|TIMeout|RUNT|WINDow|DELay| SETup|NEDGe|RS232|IIC|SPI|CAN|LIN|FLEXray|IIS|M1553 (SETup = the setup&hold trigger) sweep: AUTO|NORMal|SINGle coupling: AC|DC|LFReject|HFReject (edge trigger, analog source only) holdoff: 8 ns .. 10 s (unavailable for VIDeo/TIMeout/NEDGe/serial types) noise_reject: analog-channel trigger sources only
Inputs: mode, sweep, holdoff, coupling, +1 more. Returns: result
set_trigger_delayC
Delay trigger between two edges (event A -> event B).
slope_a/slope_b: POSitive|NEGative; delay_type: GREater|LESS|GLESs|GOUT ('<' lower, '>' upper, inside, outside).
Inputs: extra, level_a, level_b, slope_a, +6 more. Returns: result
set_trigger_durationC
Duration (time-qualified logic-state) trigger.
pattern: per-channel states for CH1..CH4, e.g. 'HLXL' (H=high, L=low, X=don't care) -> ':TRIGger:DURation:TYPE H,L,X,L' ('HLXL' is auto-expanded to the comma form); when: GREater|LESS|GLESs|UNGLess; level: per-channel threshold in volts, requires level_source (e.g. 'CH2') -> ':TRIGger:DURation:LEVel ,'.
Inputs: when, extra, level, source, +4 more. Returns: result
set_trigger_edgeB
Edge trigger (most common). Switches TRIGger:MODE to EDGE.
source: CH1..CH4 / D0..D15; slope: POSitive|NEGative|RFALl; level: volts (analog: ±4.5×scale−offset; digital: ±15 V)
Inputs: extra, level, slope, source. Returns: result
set_trigger_nth_edgeB
Nth-edge burst trigger (fires on the Nth edge after a quiet period).
slope: POSitive|NEGative; idle_time: 16 ns .. 10 s; edge: which edge to trigger on, 1 .. 65535; level: volts (analog: ±4.5×scale−offset; digital: ±15 V).
Inputs: edge, extra, level, slope, +2 more. Returns: result
set_trigger_patternB
Pattern trigger.
pattern: per-channel state string for CH1..CH4, e.g. 'HHLL' or 'H,H,L,L' (H=high, L=low, X=don't care, R=rising, F=falling; at most one edge; 'HHLL' is auto-expanded to the comma form the firmware requires); level: per-channel threshold in volts, requires level_source (e.g. 'CH2') -> ':TRIGger:PATTern:LEVel ,'.
Inputs: extra, level, source, pattern, +1 more. Returns: result
set_trigger_pulse_widthC
Pulse width trigger. polarity: POSitive|NEGative; when: GREater|LESS|GLESs (greater/less/within range of the two widths). Widths in seconds (lower 1 ns .. upper; upper .. 10 s).
Inputs: when, extra, level, source, +3 more. Returns: result
set_trigger_runtC
Runt pulse trigger.
polarity: POSitive|NEGative; when: NONE|GREater|LESS|GLESs (width qualification).
Inputs: when, extra, source, level_a, +4 more. Returns: result
set_trigger_serialA
Serial-bus trigger: RS232 | IIC | SPI | CAN | LIN | FLEXray | IIS | M1553.
Typed params map to the documented keywords of the selected protocol
(sent as :TRIGger:: ; booleans are sent as 1/0,
everything else verbatim):
RS232: source level polarity when data baud width stop parity buser
IIC: scl sda clevel dlevel when awidth address direction dbytes
data currbit code
SPI: clk scl miso sda cs clevel dlevel slevel slope when mode
timeout width data currbit code
CAN: source stype when baud spoint extended define dwidth data
currbit code level
LIN: source level standard baud samplepoint when error id data
currbit code
FLEXray: source when level baud pos error symbol frame define idcmp
cyccomp maxcy mincy maxid minid ch
IIS: clock data_source ws_select clock_slope clevel slevel dlevel
alignment uwidth width dmin dmax when audio data code
M1553: source when polarity window sync error datcomp datvalue dmin
dmax drta dbit code alevel blevel
Anything else: pass extra={"KEYWORD": value} (KEYWORD must be
documented for that protocol in manual section 3.27).
Inputs: params (required), protocol (required), extra. Returns: result
set_trigger_setup_holdA
Setup & Hold trigger (:TRIGger:MODE SETup, subsystem :TRIGger:SHOLd).
data_source/clock_source: CH1..CH4 or D0..D15 (data and clock lines); slope: POSitive|NEGative (clock edge); pattern: H|L (level the data must hold stable across the clock edge); condition: SETup|HOLD|SETHold; setup_time/hold_time: 1 ns .. 10 s; data_level/clock_level: volts (analog: ±4.5×scale−offset; digital: ±15 V).
Inputs: extra, slope, pattern, condition, +6 more. Returns: result
set_trigger_slopeC
Slope (rise/fall time) trigger.
polarity: POSitive|NEGative; when: GREater|LESS|GLESs; window: TA|TB|TAB (which level limit(s) the knobs adjust).
Inputs: when, extra, source, window, +5 more. Returns: result
set_trigger_timeoutB
Timeout trigger: fires when the signal stays on one side of the level.
slope: POSitive|NEGative|RFALl; time: 1 ns .. 10 s.
Inputs: time, extra, level, slope, +1 more. Returns: result
set_trigger_videoC
Video trigger.
mode: ODDField|EVENfield|LINE|ALINes; polarity: POSitive|NEGative; line: 1 .. 1125 (limit depends on the standard); level: volts; standard: PALSecam|NTSC|480P|576P|720P60|720P50|720P30|720P25|720P24| 1080P60|1080P50|1080P30|1080P25|1080P24|1080I60|1080I50
Inputs: line, mode, extra, level, +3 more. Returns: result
set_trigger_windowB
Window trigger (enter/exit/timeout within a voltage window).
slope: POSitive|NEGative|RFALl; position: EXIT|ENTer|TIME; time: 1 ns .. 10 s (only for position=TIME).
Inputs: time, extra, slope, source, +3 more. Returns: result
smb_connectA
Connect the configured SMB share (:SAVe:SMB:CONNect).
Check the result with get_smb_status.
Inputs: no named parameters. Returns: result
smb_disconnectB
Disconnect the SMB share (:SAVe:SMB:DISConnect).
Inputs: no named parameters. Returns: result
sync_awg_phaseB
Perform the "align phase" operation (manual 3.25.7).
Sends :SOURce:PHASe:SYNChronize: both generator channels are re-configured to output at their preset frequency and phase; signals whose frequencies are identical (or integer multiples) come out phase-aligned.
Inputs: channel (required). Returns: result
wait_completeB
Block until all pending operations finish (*OPC?).
use_wai: also send *WAI first — the IEEE488.2 wait-to-continue command. On this firmware *WAI is a compatibility no-op, kept for completeness.
Inputs: timeout, use_wai. Returns: result
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
TDQS
Scored across 142 tools
There are many overlapping families: get_channel vs get_channel_full, get_timebase vs get_timebase_full, get_math_config vs get_math_config_full, configure_bus vs configure_bus_rs232/iic/spi/etc., set_counter vs set_measure_counter, and multiple screenshot/save-image tools. Descriptions often clarify differences, but the set has several tool pairs whose boundaries an agent could easily misselect among.
Mostly consistent snake_case verb_noun naming (get_, set_, configure_, measure_, save_, load_, read_) is used throughout. Minor deviations exist, such as bare verbs reset/autoscale, noun-like scpi, and get_screenshot vs get_screenshot_data, but the overall convention is readable and predictable.
142 tools is an extreme mismatch for an MCP server, far beyond the typical 3-15 range. The surface is effectively a full SCPI wrapper, creating excessive cognitive load and making tool selection impractical for an agent despite the exhaustive coverage.
The server covers nearly every major oscilloscope subsystem: system, LAN, save/load, triggers, channels, timebase, acquisition, measurements, cursors, counter/DVM, waveform, math, reference, bus decode, AWG, Bode, display, histogram, mask, search, record, logic analyzer, and connection management. The scpi escape hatch also prevents dead ends for undocumented or unexposed operations.
Related MCP Connectors
Documentation for the Spektralwerk spectrometer SCPI API as a streamable HTTP MCP Server
QuLab MCP remote server (Streamable HTTP) for computational science and lab tools.
Protocol-native energy infrastructure orchestration for AI data centers. Provides 46 MCP tools across 8 grid protocols (IEC-61850, DNP3, Modbus, OCPP, OpenADR, IEEE 2030.5, IEC 60870-5-104, ICCP) with 5 core API primitives: connect, dispatch, settle, comply, and intel. Enables AI agents to programmatically interact with substations, grid interfaces, and energy assets for real-time workload-grid coordination.
Remote MCP for 9192 discovery, pricebook, payment rails, GET_PULSE quotes, and receipt checks.
Related MCP Servers
- AlicenseNot gradedqualityDmaintenanceEnables control and querying of Rigol DHO824 oscilloscopes, allowing users to capture waveforms, take screenshots, and interact with oscilloscope settings through natural language.54 PyPI7MIT
- AlicenseNot gradedqualityCmaintenanceEnables AI agents to control Rigol MSO5000 oscilloscopes through VISA, including acquisition, channels, trigger, timebase, waveform generator, display, and front-panel controls, with risk-based permission gating for direct SCPI operations.4MIT
- AlicenseAqualityBmaintenanceEnables LLMs to control RIGOL oscilloscopes over SCPI via LAN or USB, including configuring channels/timebase/trigger, taking measurements, capturing waveforms and screenshots, decoding serial protocols, running FFT analysis, and controlling the built-in AFG.38MIT
- AlicenseAqualityCmaintenanceEnables MCP-compatible AI clients to operate a RIGOL MHO98 oscilloscope over USB, including configuration, waveform and measurement acquisition, FFT analysis, and protocol decoding.16MIT