model_check
Checks a Ventsim model file before opening it for loose ends, duplicate or zero-length airways, blocked fans, and conflicting flows, and explains how to fix each issue.
Instructions
The Ventsim warnings and errors that can be found from the file (Ventsim manual, Appendix E), before opening it in Ventsim: loose ends without surface or closed-end setting (no entry / no exit), duplicate airways (two airways between the same junctions), zero-length airways, running fans or fixed flows whose air has no path (operating fan blocked / fix stopped), fans in series, stoppings in series and conflicting fixed flows on one path. Each item says how to fix it; fix_model applies the automatic fixes to a copy. Not covered (need a simulation): stalled or reversed fans (fan_duty_check), recirculation (recirculation_check), heat and density warnings.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"path": "<path>"
},
"name": "model_check"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| path | Yes | ||
| limit | No |