Skip to main content
Glama
ventsim-mcp

ventsim-mcp

by agenticeram

contaminant_spread

Predict steady-state gas or smoke spread through mine airways from defined release sources, including recirculation and airflow changes, and list airways above a concentration threshold.

Instructions

EXPERIMENTAL. Steady-state spread of a gas or smoke released in airways: 'sources' = {Unique No: release rate in m3/s of pure gas} (methane make, CO from a fire, averaged blasting fumes...). Fully mixed at junctions, recirculation included. include_file_sources=True also reads the model's own 'Base Injection' (m3/s) x 'Base Concentration' (ppm) inputs (this reading of Ventsim's fields is not verified). Airflow changes as in simulate_heat. Returns the airways above threshold_ppm with their concentration (ppm and %), most contaminated first.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "path": "<path>"
    },
    "name": "contaminant_spread"
  }
}

Input Schema

NameRequiredDescriptionDefault
pathYes
limitNo
airflowNosaved
sourcesNo
fans_offNo
fan_speedNo
threshold_ppmNo
resistance_scaleNo
include_file_sourcesNo

Schema Changelog

Changes observed during successful MCP inspections.

  1. Addedv0.14.0

TDQS

A3.6/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description carries the full burden and does well: it discloses the mixing model ('Fully mixed at junctions, recirculation included'), the airflow-modelling side effect, the return ordering ('most contaminated first'), units (m3/s, ppm and %), and two honest caveats (EXPERIMENTAL, Ventsim field reading 'not verified'). It omits cost/runtime and any permission or failure-mode notes, which keeps it short of a 5.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Front-loaded with the EXPERIMENTAL marker and the core purpose, and the parentheticals ('methane make, CO from a fire, averaged blasting fumes') earn their space by clarifying valid source types. A few clauses are dense and run together, but there is no filler.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

Reasonable for a complex simulation: the modelling assumptions, source encoding, and result shape are covered, and the absence of an output schema is offset by the described return values. However, with 9 parameters at 0% schema coverage, several inputs (fans_off, fan_speed, resistance_scale, the airflow enumeration, limit) remain unexplained, which is a real gap for an agent composing a call.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 0%, so the description must compensate, and it only partly does: it fully documents the 'sources' map format (Unique No -> m3/s of pure gas), explains include_file_sources and the Base Injection/Base Concentration fallback, and clarifies threshold_ppm via the return statement. The remaining parameters (limit, airflow, fans_off, fan_speed, resistance_scale) get no meaning beyond a pointer to simulate_heat, leaving roughly half the surface undocumented.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb+resource ('Steady-state spread of a gas or smoke released in airways') and flags the tool as EXPERIMENTAL, which lets an agent place it relative to the steady-state family (radon_steady, simulate_heat) versus transient ones (contaminant_arrival). It does not name a sibling explicitly, so differentiation is inferential rather than stated.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Usage is only implied: 'steady-state' and 'Returns the airways above threshold_ppm' tell the agent what the tool reports, and 'Airflow changes as in simulate_heat' gives a cross-reference for the airflow-modelling convention. There is no explicit when-to-use/when-not guidance or named alternative (e.g. contaminant_arrival for time-dependent results).

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.