Skip to main content
Glama
ventsim-mcp

ventsim-mcp

by agenticeram

goal_seek

Calculate the fan speed percentage needed to achieve a target airflow (m³/s) in a specified airway using bisection, without changing the model.

Instructions

EXPERIMENTAL. Fan speed (% of curve speed) that gives target_m3s in one airway (Ventsim's Goal Seek, fan speed mode), by bisection. The model is not changed: apply the result with edit_airways (Fan Speed) and confirm in Ventsim.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "path": "<path>",
      "fan_unique_no": "<fan_unique_no>",
      "target_unique_no": "<target_unique_no>",
      "target_m3s": "<target_m3s>"
    },
    "name": "goal_seek"
  }
}

Input Schema

NameRequiredDescriptionDefault
pathYes
speed_maxNo
speed_minNo
target_m3sYes
fan_unique_noYes
target_unique_noYes

Schema Changelog

Changes observed during successful MCP inspections.

  1. Addedv0.14.0

TDQS

B3.4/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With zero annotations, the description carries the full burden and does disclose key behavior: flagged EXPERIMENTAL, explicitly non-mutating (the model is not changed), bisection-based, and the return is a fan speed percentage needing manual application. It omits failure behavior, e.g. what happens if no solution exists between speed_min and speed_max.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Three tight sentences, front-loaded with the EXPERIMENTAL warning and the core definition, then the follow-up workflow. No filler, though the parenthetical references are dense and the second clause takes a reread.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 6-parameter, no-annotation, no-output-schema tool, the description covers behavior and the apply-afterwards loop but leaves parameter ambiguity and non-convergence handling to guesswork. It is enough to understand the tool but not quite enough to call it correctly on the first try.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters2/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 0% for 6 parameters. The description clarifies target_m3s and hints that speed_min/speed_max bound the bisection search, but it never explains path, and critically never distinguishes fan_unique_no (the fan being tuned) from target_unique_no (the airway whose flow is matched) — the single most error-prone pair here.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a concrete computation: the fan speed (% of curve speed) that achieves target_m3s in one airway, solved by bisection. This distinguishes it from mutation siblings like edit_airways, though it never names other calculation siblings (optimize_fans_tool, calibrate_airflow) or contrasts with them.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Implied usage is clear (size a fan to hit a target flow), and it adds a real workflow rule: apply the answer with edit_airways and confirm in Ventsim. But it never says when NOT to use it or how it differs from the other fan/flow-analysis tools in the sibling list.