Skip to main content
Glama
ventsim-mcp

ventsim-mcp

by agenticeram

Server Configuration

Describes the environment variables required to run the server.

NameRequiredDescriptionDefault

No arguments

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

This server publishes no instructions, or was last inspected before Glama recorded them.

Capabilities

Features and capabilities supported by this server

Protocol revision2025-11-25

CapabilityDetails
tools
{
  "listChanged": false
}
prompts
{
  "listChanged": false
}
resources
{
  "subscribe": false,
  "listChanged": false
}
experimental
{}

Tools

Functions exposed to the LLM to take actions

NameDescription
model_summaryC

Summarise a Ventsim .vsm file: title, version, airway/fan counts, total length.

list_airwaysB

List airways. Filter by name/notes text or minimum velocity (m/s); sort by any returned field (e.g. 'Quantity', 'Length', 'Velocity m/s', 'Pressure Branch').

get_airwayB

Every column of one airway (by 'Unique No'), including heat and gas fields.

list_fansC

Airways that carry a fan, with duty airflow, fan pressure and power.

check_flow_balanceA

Mass-balance check of simulated airflow at every junction (mass flow expressed as m3/s of standard 1.2 kg/m3 air when the file has it, else volume flow).

Only airways of the simulated stage are used. Junctions are found by matching airway end coordinates. Nodes touched by a single airway (portals, dead ends) are skipped. A large imbalance usually means the model needs to be re-simulated, contains recirculation fans, or has disconnected nodes.

velocity_checkA

Find airways whose simulated air velocity (m/s) is above max_velocity or, if min_velocity > 0, below it while still carrying air (e.g. dust/gas settling limits). Airways with zero airflow are ignored.

fan_summaryC

Totals for all fans: count by model, airflow, total fan power (kW).

compare_modelsB

Compare two saved versions of a model by Unique No: added/removed airways and those whose airflow (m3/s) or branch pressure (Pa) changed by more than min_change.

what_ifA

EXPERIMENTAL what-if airflow estimate. Re-solves the network with the stored fan curves and resistances, scaling resistance of given airways (Unique No -> factor, e.g. {"12": 50} for a new door) and/or switching fans off (list of Unique No), and returns the airflow change per airway relative to an unmodified solve of the same model. 'baseline_fit' tells you how well the solver reproduces the flows saved by Ventsim (mean_rel_error = total absolute flow error / total flow). If 'reliable' is false, or junctions are unbalanced in the saved flows (ducting or leakage links the solver cannot see), do not trust the numbers. Always confirm in Ventsim.

export_csvC

Write airways to a CSV file. 'columns' may name any column of the .vsm table; by default the common fields are exported.

edit_airwaysA

EXPERIMENTAL. Copy the model to 'out_path' (never overwrites the source) after changing text fields. Each edit: {"unique_no": "12", "field": "Notes", "value": "..."}. Allowed fields: Notes, Group, Branch Name. Geometry and results are not touched, so open the copy in Ventsim and re-simulate.

Prompts

Interactive templates invoked by user choice

NameDescription

No prompts

Resources

Contextual data attached and managed by the client

NameDescription

No resources

TDQS

B3.2/5.0

Scored across 11 tools

Disambiguation5/5

Each tool targets a clearly distinct granularity or operation: summaries vs. listings vs. single records, diagnostic checks (flow balance, velocity), lifecycle operations (compare, what-if, export, edit). The summary/list split for fans (fan_summary, list_fans) and airways (model_summary, list_airways, get_airway) is well delineated by the descriptions.

Naming Consistency3/5

All names are snake_case and readable, but the convention is mixed: most are verb-first (list_airways, get_airway, check_flow_balance, compare_models, export_csv, edit_airways), while several are noun-first (model_summary, fan_summary, velocity_check) and one is a phrase (what_if). This goes beyond minor deviation, though the pattern is still interpretable.

Tool Count5/5

11 tools is well within the ideal 3–15 range and each tool maps to a distinct, valuable function for a ventilation-model analysis server: summarisation, listing, diagnostics, comparison, what-if, export and editing. No tool feels redundant or padding.

Completeness4/5

The analysis surface is fairly comprehensive—summaries, airway/fan inspection, mass-balance and velocity checks, model comparison, what-if solving, CSV export, and limited text-field editing. Gaps remain: no node/junction-level inspection, no editing of geometry or ventilation parameters, and no simulation execution (deferred to Ventsim), but these are reasonable boundaries for a read/analysis companion.

Maintenance

ActivityMaintained
ResponsivenessNo recent community issues