Check each fan's operating point against its saved Ventsim curve, reporting airflow, curve position, stall margin, efficiency, and status to flag near-stall, stalled, or off-curve fans.

Instructions

Where every fan of the simulated stage runs on its curve: airflow per fan, position between the first and last curve point (0..1), margin to the stall peak, static efficiency as saved by Ventsim and a status: ok, near_stall (within 10 % of the peak flow), stall_region (left of the pressure peak), beyond_curve, below_curve, no_flow, fixed_flow (airflow fixed, the curve is not used), off or no_curve. Uses the results saved in the file.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "path": "<path>"
    },
    "name": "fan_duty_check"
  }
}

Input Schema

NameRequiredDescriptionDefault
pathYes
only_problemsNo

Schema Changelog

Changes observed during successful MCP inspections.

  1. Addedv0.14.0

TDQS

C2.9/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description bears the full burden. It does disclose the important behavior that the tool reads saved results rather than re-running the simulation, and it exhaustively defines the status enum values including fixed_flow, beyond_curve and no_flow, which is genuinely useful behavioral detail. However it never states explicitly whether the model file is modified, whether it requires the file to be open/locked, or how errors surface.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness3/5

Is the description appropriately sized, front-loaded, and free of redundancy?

It is a single long sentence that spends most of its length enumerating output statuses rather than front-loading what the tool does. Nothing is padded exactly, but the opening 'Where every fan ... runs on its curve' is a weak lead that delays the operational meaning.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

Since there is no output schema, the description's rich explanation of returned fields and statuses is appropriate and largely complete on the output side. It is incomplete on the input side, leaving both parameters undocumented, and with no annotations it should say more about side effects and prerequisites than it does.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters2/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 0% for both parameters. The description says nothing about the required 'path' argument or the 'only_problems' boolean, which is the single most consequential knob (filtering to problem fans) and is left completely unexplained. The description therefore fails to compensate for the schema gap.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names a specific resource and analysis: each fan of the simulated stage evaluated on its curve, with airflow, curve position, stall margin and efficiency. It does not open with an explicit verb ('check'/'report'), and it never distinguishes itself from siblings like fan_summary or model_check, so an agent must infer the diagnostic intent from the field list.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines2/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

There is no when-to-use or when-not guidance, and no alternatives are named. The only usage signal is the trailing clause 'Uses the results saved in the file', which hints at a prerequisite (existing saved simulation results) but does not state it as a condition.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.