Sysmac Studio File Editor MCP

Sysmac Studio File Editor MCP

by il-prof-f-a

Sysmac Studio File Editor MCP

CI License: PolyForm Noncommercial 1.0.0

An offline-first Model Context Protocol (MCP) server for inspecting, comparing, and transactionally editing local copies of Omron Sysmac Studio projects.

The project is experimental and source-available under the PolyForm Noncommercial License 1.0.0. It is not an Omron product and is not affiliated with or endorsed by Omron.

Safety and privacy: The server does not connect to a PLC, download a program, or force I/O. Work on an authorized copy, review every proposed change, and rebuild the exported candidate in Sysmac Studio before relying on it. A successful build does not verify machine behavior or wiring. Project names, source, and tool results may be sent to the model provider by your MCP client; use only data you are authorized to share and follow your organization's data-handling rules.

What it does

  • Inspects .smc2 archives and reports observed project members.

  • Reads and compares project copies, with structural comparison of observed variables, POU, tasks, DataTypes, hardware, and I/O.

  • Stages supported offline edits to ST/LD sections, variables, POU, task assignments, I/O bindings, and selected DataTypes.

  • Uses transactions with expected revisions, previews, partial validation, commit to a local working copy, rollback, and export to a new path.

  • Generates and imports a bounded subset of PLCopen IEC XML for ST, Ladder, globals, and selected DataTypes.

  • Optionally communicates with a locally installed Sysmac Studio through typed Windows-only operations, including open-copy, runtime status, rebuild, and guarded export.

This is not a full IEC 61131-3 parser, compiler, or semantic checker. Unsupported or incomplete structures are reported as limitations.

Related MCP server: plc-ai-agent

Requirements

Offline MCP core

  • Python 3.11 or newer.

  • An MCP client that supports the local stdio transport.

  • No Sysmac Studio installation, cloud account, API key, or listening network port is required for the core archive and transaction workflows.

Windows is the primary development and validation platform. The Python core may run in other environments with compatible Python dependencies, but Linux, macOS, and WSL are not currently part of the tested support matrix.

Optional Sysmac Studio integration

  • Windows x64 and Sysmac Studio installed locally.

  • The vendor contract assemblies and .NET Framework compiler supplied by the local installation, to build the WCF client.

  • A local Node.js executable and the verified Frida 17.23.2 package, to create the hash-pinned runtime profile used by runtime operations.

  • User approval of the normal Windows UAC prompt for operations that require elevation.

The optional Windows integration depends on the local Sysmac Studio release. The repository does not include Omron binaries. The integration is experimental and must be validated against the exact IDE version and an authorized demonstration project.

Optional EtherCAT NRBF helper

Building the Windows x64 helper requires the .NET SDK version pinned in bridge/SysmacFormats/global.json (currently 10.0.403) and NuGet package restore. It is not needed for the basic MCP server.

Install on Windows

Clone the repository and create a virtual environment from the project root:

git clone https://github.com/il-prof-f-a/sysmacstudio-file-editor-mcp.git
cd sysmacstudio-file-editor-mcp
py -3.11 -m venv .venv
.\.venv\Scripts\python.exe -m pip install --upgrade pip
.\.venv\Scripts\python.exe -m pip install -e .

For development and tests, install the optional development dependencies:

.\.venv\Scripts\python.exe -m pip install -e ".[dev]"

The server communicates with its MCP client over standard input/output. It does not open a listening TCP port.

Configure an MCP client

Add an entry like this to the MCP client's configuration, replacing both paths with absolute paths on your machine:

{
  "mcpServers": {
    "sysmacstudio": {
      "command": "C:/path/to/sysmacstudio-file-editor-mcp/.venv/Scripts/python.exe",
      "args": [
        "-m",
        "sysmac_mcp",
        "--workspace",
        "C:/path/to/sysmacstudio-file-editor-mcp/workspace"
      ]
    }
  }
}

See mcp-config.example.json for the optional IDE environment variables. The supplied sample contains placeholders and must be adapted locally. Do not commit a local configuration, runtime profile, project archive, or receipt.

You can also start the server manually:

.\.venv\Scripts\python.exe -m sysmac_mcp --workspace .\workspace

The read-only command-line reports are:

.\.venv\Scripts\python.exe -m sysmac_mcp inspect 'C:\path\to\project.smc2'
.\.venv\Scripts\python.exe -m sysmac_mcp compare 'C:\path\to\before.smc2' 'C:\path\to\after.smc2'
.\.venv\Scripts\python.exe -m sysmac_mcp compare-projects 'C:\path\to\before.smc2' 'C:\path\to\after.smc2'
  1. Read plc_get_capabilities, then open an authorized project copy with plc_open_project.

  2. Inspect the relevant variables, POU, sections, tasks, hardware, and references.

  3. Start a transaction with plc_begin_transaction, passing the revision returned by the project read.

  4. Preview with plc_preview_changes and run plc_validate. Review every changed archive member.

  5. Commit to the MCP-managed local copy with plc_commit_changes, or discard the staged changes with plc_rollback.

  6. Export to a new path with plc_export_project. Treat the output as a candidate until Sysmac Studio imports and rebuilds it.

The local IDE tools are separate from archive editing. They use explicit, typed operations and do not expose arbitrary WCF method calls. plc_ide_rebuild_active rebuilds the active offline solution; it does not download to a controller. plc_ide_export_active uses the native IDE export path with identity, destination, save, and session checks. Both require the optional Windows integration and its UAC flow.

Data handling

  • Project snapshots, transactions, IDE jobs, receipts, and runtime profiles belong in local ignored folders such as workspace/.

  • Do not add .smc/.smc2 archives, extracted project data, IDE logs, runtime profiles, receipts, or customer identifiers to the repository or an issue.

  • .gitignore helps prevent accidental additions, but does not remove files already tracked or erase Git history. Review the staged file list before committing.

  • The server uses local stdio; your MCP client and model provider may process tool output separately. Choose a client and model approved for the project data you use.

Contributing and support

Bug reports and feature suggestions are welcome through GitHub Issues. Questions and design discussion can go to GitHub Discussions. Read CONTRIBUTING.md before opening a pull request. Never attach a real customer project or unsanitized diagnostic output.

For security concerns, follow SECURITY.md and do not publish exploit details in an issue.

Development checks

.\.venv\Scripts\python.exe -m pytest -q
.\.venv\Scripts\python.exe -m ruff check src tests
.\.venv\Scripts\python.exe -m build

License

Original project material is licensed under the PolyForm Noncommercial License 1.0.0. Its terms allow only the purposes defined by that license; a separate permission from the relevant rights holder is required for uses outside those terms. This is a source-available, noncommercial project, not OSI-approved open source: the Open Source Definition does not permit licenses to restrict fields of endeavor such as business use (OSI definition).

Runtime dependencies are listed in pyproject.toml and remain under their respective upstream licenses. The license summary above is informational; the complete terms in LICENSE govern.

Available Tools

51 tools
plc_analyze_symbolB
Read-onlyIdempotent

Resolve one declaration's observed ST/LD references by scope, external aliases and known members/parameters. Return paginated references, diagnostics and explicit incomplete coverage; no full type checker or HMI/library analysis.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
project_idYes
variable_idYes
transaction_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_assign_programA

Assign, move or reorder one Program in an existing task. Position is one-based; omitted preserves the current position or appends a new assignment. Startup omitted preserves an existing setting, or enables a new assignment. Atomically update task XML and OEM links; reject inconsistent identities, ambiguous instances and cross-controller moves. No PLC or Sysmac build implied.

NameRequiredDescriptionDefault
startupNo
task_idYes
positionNo
program_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_begin_transactionB

Begin persistent staging against the current project revision; original files remain untouched.

NameRequiredDescriptionDefault
project_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_bind_ioC

Stage a binding to an originally observed address or enabled configured port resolved by an exact local profile. Reject occupied, incompatible and known overlapping output aliases.

NameRequiredDescriptionDefault
addressYes
variable_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_commit_changesA

Commit staging to a new local revision. This does not apply changes in Sysmac Studio or compile PLC code.

NameRequiredDescriptionDefault
transaction_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_compare_filesC
Read-onlyIdempotent

Compare hashes and ZIP member content; this does not prove PLC semantic equivalence.

NameRequiredDescriptionDefault
afterYes
beforeYes

Output Schema

NameRequiredDescription

No output parameters

plc_compare_projectsA
Read-onlyIdempotent

Compare two local SMC2 copies by observed objects, variables, ST/LD and tasks, retaining every ZIP member delta. Return bounded fingerprints and paginated model/archive differences. Logical paths match objects across ID changes; ambiguous matches and unacquired content are explicit. This does not prove functional equivalence, successful build or IDE round-trip.

NameRequiredDescriptionDefault
afterYes
limitNoMaximum items, 1–200.
beforeYes
offsetNoZero-based offset from the previous page.

Output Schema

NameRequiredDescription

No output parameters

plc_create_pouA

Stage a new POU from a readable single-section template in the same controller/folder. Infer Program/Function/FB and ST/LD from the template; provide fresh declarations and exactly one ST source or native LD rungs. Add fresh IDs and models atomically without copying application code/build caches. Result remains unverified until Sysmac rebuild.

NameRequiredDescriptionDefault
definitionYes
transaction_idYes
template_pou_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_create_variableB

Stage a declaration in an existing global or local VAR group. Case-insensitive collisions are rejected.

NameRequiredDescriptionDefault
nameYes
table_idYes
data_typeYes
initial_valueNo
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_delete_data_typeA
Destructive

Stage deletion of one unreferenced top-level leaf DataType. Requires an exactly observed controller table, matching listed name/BaseType, complete controller source and no references in declarations, source, or other DataTypes. Nested members, libraries, external consumers, and Sysmac build are not covered; the archive member and original project remain preserved until commit/export.

NameRequiredDescriptionDefault
data_type_idYes
expected_nameYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.
expected_base_typeYes

Output Schema

NameRequiredDescription

No output parameters

plc_delete_pouA
Destructive

Stage removal of one POU from the OEM project tree. Refuses assigned Programs, observed source/declaration references and incomplete controller source or DataTypes; archive members are preserved as unreferenced data. External consumers are not acquired, and Sysmac rebuild is required before use.

NameRequiredDescriptionDefault
pou_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_delete_variableB
Destructive

Stage removal of one variable only when its observed declarations and source are safe. Refuses read-only or I/O-bound variables, observed code/declaration references, incomplete source, and global declarations with VAR_EXTERNAL aliases. External consumers are not acquired; no Sysmac build is implied.

NameRequiredDescriptionDefault
variable_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_export_projectA

Write an unverified SMC2 candidate to a new path; never overwrite the original or another file.

NameRequiredDescriptionDefault
project_idYes
destinationYes

Output Schema

NameRequiredDescription

No output parameters

plc_find_referencesA
Read-onlyIdempotent

Find lexical ST/LD references excluding comments/strings. Does not resolve scope or external HMI dependencies.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
symbolYes
project_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_generate_iec_xmlA

Generate IEC 61131-10 ST or basic Ladder POUs and variables for import. Validate against a local XSD when available; never imply IDE import/build.

NameRequiredDescriptionDefault
nameYes
pousYes
destinationYes
schema_pathNo
global_variablesYes

Output Schema

NameRequiredDescription

No output parameters

plc_get_capabilitiesB
Read-onlyIdempotent

Report implemented adapters, experimental formats and unavailable Sysmac operations.

NameRequiredDescriptionDefault

No parameters

Output Schema

NameRequiredDescription

No output parameters

plc_get_project_infoA
Read-onlyIdempotent

Read controller metadata, object counts and explicit unknown coverage for an opened project.

NameRequiredDescriptionDefault
project_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_ide_close_activeA

Close only the expected active normal imported Sysmac solution. Requires normal Windows UAC, the same process-start and solution identities, a completed native editor flush, and a clean model. Refuses file mode, AutoConnect, save suppression, dirty state, importing, or changed context. Uses the normal UserCloseSolution command once and requires matching close events plus a later empty-solution snapshot; never answers save prompts. Timeout remains unknown without retry. Does not save, export, compile, import, or operate a PLC.

NameRequiredDescriptionDefault
process_idYes
solution_idYes
process_started_utcYes

Output Schema

NameRequiredDescription

No output parameters

plc_ide_export_activeA

Save and export the attested active normal imported solution through the pinned Sysmac runtime. Provide process identity from runtime_status and the solution GUID/storage_folder from list_projects. Destination must be a new local SMC2 path outside the persistence folder and on the same drive. The export uses native command rules and may show a normal Sysmac prompt; it refuses file mode, AutoConnect, changed identities, suppressed saves, persistence IO errors, and existing output paths. Publishes only a readable SMC2 copy; no PLC connection or download.

NameRequiredDescriptionDefault
process_idYes
destinationYes
solution_idYes
storage_folderYes
process_started_utcYes

Output Schema

NameRequiredDescription

No output parameters

plc_ide_list_projectsA
Read-onlyIdempotent

Read a bounded page of persisted projects in the local Sysmac IDE through the pinned runtime adapter and normal UAC. Returns solution GUIDs and process start identity for open_existing, including from the start page. Does not import, open, save or compile a project; storage folders are IDE locations, not source archive paths.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
process_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_ide_open_copyA

Prepare a verified copy of the committed revision and open it in the configured Sysmac WCF host. Requires Windows UAC. Return actual OpenFromFile callback; duplicate projects remain refused, without overwrite/delete. Does not compile.

NameRequiredDescriptionDefault
project_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_ide_open_existingA

Open one persisted Sysmac project by the GUID returned by list_projects. Requires normal UAC, the same process start and an idle empty start page. Preserves vendor permission/availability checks and requires matching completion event plus final solution identity. Does not close another project, import/overwrite/delete, save, compile or operate a PLC. Timeout remains unknown without automatic retry.

NameRequiredDescriptionDefault
process_idYes
solution_idYes
process_started_utcYes

Output Schema

NameRequiredDescription

No output parameters

plc_ide_probeA
Read-onlyIdempotent

Check the local Sysmac WCF endpoint with the direct non-elevated probe. No project is opened or compiled, and no UAC prompt is required.

NameRequiredDescriptionDefault

No parameters

Output Schema

NameRequiredDescription

No output parameters

plc_ide_rebuild_activeA

Rebuild the active offline NX controller only if the process start, solution and controller identities still match runtime_status. Requires UAC. Return correlated completion, native result and compiler diagnostics; timeout is unknown and never retried. Does not import, save or connect to a PLC.

NameRequiredDescriptionDefault
process_idYes
solution_idYes
controller_idYes
process_started_utcYes

Output Schema

NameRequiredDescription

No output parameters

plc_ide_runtime_statusA
Read-onlyIdempotent

Read the active local Sysmac solution/controller identities, rebuild availability and file-mode state through the pinned runtime adapter. Requires normal Windows UAC and explicit Sysmac PID; does not save, export or compile. Use its process start identity and GUIDs for rebuild.

NameRequiredDescriptionDefault
process_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_inspect_fileB
Read-onlyIdempotent

Inspect a local file without modifying it; return digest and bounded container summary.

NameRequiredDescriptionDefault
pathYes

Output Schema

NameRequiredDescription

No output parameters

plc_list_data_typesB
Read-onlyIdempotent

List observed native DataType definitions or a type's direct members. IDs use the entity ID and XML path, not a vendor GUID; table provenance and partial coverage are returned.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
parent_idNo
project_idYes
controller_idNo
transaction_idNo

Output Schema

NameRequiredDescription
itemsYes
totalYes
tablesYes
next_offsetYes
table_countYes
completenessYes
definition_countYes
nested_member_countYes
plc_list_hardwareB
Read-onlyIdempotent

List configured NX, built-in and EtherCAT modules using exact local profiles. Configuration is not physical verification; coverage remains partial.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
project_idYes
transaction_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_list_ioA
Read-onlyIdempotent

Read declared variable-to-address bindings. These are observed bindings, not a complete hardware inventory.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
project_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_list_portsB
Read-onlyIdempotent

List configured or observed ports, types, addresses and bindings. Available means resolved, enabled and unoccupied, including known output aliases; it does not imply hardware/build verification.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
directionNo
module_idNo
project_idYes
available_onlyNo
transaction_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_list_pousB
Read-onlyIdempotent

List programs, functions and function blocks. Use returned IDs for reads and edits.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
project_idYes
transaction_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_list_tasksB
Read-onlyIdempotent

Read task metadata and associated programs from the project.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
project_idYes
transaction_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_list_variablesB
Read-onlyIdempotent

List global or POU-local declarations and preserved attributes. Scope is 'global' or a POU ID.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
queryNo
scopeNo
offsetNoZero-based offset from the previous page.
project_idYes
transaction_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_open_projectC

Acquire a native SMC2 into immutable local storage. Return project ID, revision and coverage.

NameRequiredDescriptionDefault
pathYes

Output Schema

NameRequiredDescription

No output parameters

plc_plan_renameA
Read-onlyIdempotent

Prepare a concrete native variable rename without staging. Check aliases, scope collisions, unavailable source and reference capture by rebinding; paginate proven references and report blockers. External consumers and Sysmac build remain unverified.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
new_nameYes
project_idYes
variable_idYes
transaction_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_plan_rename_data_typeB
Read-onlyIdempotent

Prepare a guarded rename of one top-level controller DataType without staging. Scan observed declarations, native DataType expressions, and typed ST/Ladder literals; report collisions and unsupported references. Libraries, external consumers, other controllers, and Sysmac build remain unverified.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
new_nameYes
project_idYes
data_type_idYes
expected_nameYes
transaction_idNo
expected_base_typeYes

Output Schema

NameRequiredDescription

No output parameters

plc_preview_changesA
Read-onlyIdempotent

Read staged operations and changed archive members before committing.

NameRequiredDescriptionDefault
transaction_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_preview_iec_xml_importA
Read-onlyIdempotent

Preview PLCopen ST POUs, simple global variables, structures, unions, named DINT enumerations, fixed one-dimensional array aliases, nested DataType namespaces, and up to 1000 ordered LD rungs. Array aliases are expanded inline in variable and structure member types; they are not registered as named native DataTypes. Structures use Sysmac's automatic NJ member layout. PLCopen DataType namespaces are flattened into the selected native table's flat symbol scope; references to imported namespaced types are rewritten, and duplicate names after flattening are rejected. Each rung must be linear or have one two-path split/join, NO/NC contacts, and one standard final coil; multi-rung files require unique explicit evaluationOrder values. Nested branches, negated coils, complex LD, variable-length/multidimensional arrays, structured initial values, namespaced POUs, and namespace comments remain blocked. New data types must fit completely observed native DataType tables; pass data_type_table_id when the project has multiple tables. All edits stay in the local transaction; no staging or Sysmac action occurs.

NameRequiredDescriptionDefault
xml_pathYes
schema_pathNo
transaction_idYes
template_pou_idsYes
expected_revisionYesProject revision read before staging this change.
data_type_table_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_read_pouA
Read-onlyIdempotent

Read POU metadata and section IDs; fetch source with plc_read_section to bound response size.

NameRequiredDescriptionDefault
pou_idYes
project_idYes
transaction_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_read_sectionB
Read-onlyIdempotent

Read source lines or native Ladder rungs, optionally from staged transaction state.

NameRequiredDescriptionDefault
limitNoMaximum items, 1–200.
offsetNoZero-based offset from the previous page.
project_idYes
section_idYes
transaction_idNo

Output Schema

NameRequiredDescription

No output parameters

plc_register_externalB

Register an existing same-controller global as VAR_EXTERNAL in one POU. Preserve source, reject local name/type conflicts and avoid duplicate aliases. Useful for repairing missing declarations reported by plc_validate.

NameRequiredDescriptionDefault
pou_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.
global_variable_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_rename_data_typeA

Stage a guarded rename of one top-level controller DataType and its observed typed references. Read plc_plan_rename_data_type first. Unsupported expressions, collisions, incomplete controller tables, and uncertain Ladder fields are rejected. No external-consumer update or Sysmac build is implied.

NameRequiredDescriptionDefault
new_nameYes
data_type_idYes
expected_nameYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.
expected_base_typeYes

Output Schema

NameRequiredDescription

No output parameters

plc_rename_variableA

Recompute and stage a guarded variable rename atomically across declarations, ST and LD. Read plc_plan_rename first. Return the new variable ID; reject incomplete affected source, collisions or reference capture. No IDE build or external-consumer updates are implied.

NameRequiredDescriptionDefault
new_nameYes
variable_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_rollbackB

Discard an active transaction. Committed revisions are not overwritten.

NameRequiredDescriptionDefault
transaction_idYes

Output Schema

NameRequiredDescription

No output parameters

plc_stage_iec_xml_importA

Stage a previously previewed PLCopen ST/linear-LD import with simple global variables and supported structures, unions, named DINT enumerations, fixed one-dimensional array aliases, and nested DataType namespaces flattened into the selected native table's flat symbol scope. Array aliases are expanded inline in variable and structure member types; they are not registered as named native DataTypes. Structures use Sysmac's automatic NJ member layout. Qualified references to imported types are rewritten and duplicate names after flattening are rejected. Pass the same DataType table entity ID used in preview when the project has multiple tables. Unsupported namespaced POUs, namespace comments, nested/complex LD, variable-length or multidimensional arrays, and structured initial values remain blocked. Source hash, table selection, plan, templates, project revision and staged snapshot must still match; commit and IDE build remain separate.

NameRequiredDescriptionDefault
xml_pathYes
schema_pathNo
transaction_idYes
expected_plan_idYes
template_pou_idsYes
expected_revisionYesProject revision read before staging this change.
data_type_table_idNo
expected_source_sha256Yes

Output Schema

NameRequiredDescription

No output parameters

plc_unassign_programB
Destructive

Stage removal of one Program assignment from the selected task. Refuses ambiguous or inconsistent task models and preserves the now-unreferenced association model file in the archive. The Program itself and its source remain unchanged; the result is unverified until Sysmac rebuild.

NameRequiredDescriptionDefault
task_idYes
program_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_unbind_ioB

Stage removal of a global variable hardware address; can be paired with bind_io in the same transaction.

NameRequiredDescriptionDefault
variable_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_update_ldB

Stage native Ladder rung objects and register newly introduced known global dependencies as VAR_EXTERNAL. Read original rungs first and preserve unknown fields.

NameRequiredDescriptionDefault
rungsYes
section_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_update_stA

Stage one ST body and register newly introduced known global dependencies as VAR_EXTERNAL. Syntax/type checking and Sysmac compilation are not implied.

NameRequiredDescriptionDefault
sourceYes
section_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_update_variableA

Stage data_type, initial_value, retained or comment fields. Unbind before changing a bound variable type. Use plc_rename_variable for renames and bind_io/unbind_io for addresses.

NameRequiredDescriptionDefault
changesYes
variable_idYes
transaction_idYes
expected_revisionYesProject revision read before staging this change.

Output Schema

NameRequiredDescription

No output parameters

plc_validateB
Read-onlyIdempotent

Validate staged models with bounded ST lexer/delimiter and scalar checks, built-in integer literal range checks, and missing VAR_EXTERNAL reports. Check complete native DataType tables for empty STRUCTs and missing explicit byte offsets in OffsetType=User structures; BOOL members also require a bit offset. Automatic NJ/CJ offsets are not diagnosed. Scan Ladder for unsupported instructions. Function calls, members, arrays, enums, unions, references, library types, full ST grammar, Ladder semantics, DataType layout calculation, and Sysmac build remain outside this partial analysis; coverage is returned explicitly.

NameRequiredDescriptionDefault
transaction_idYes

Output Schema

NameRequiredDescription

No output parameters

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

  1. 51 tool updatesv0.1.0
    • First observedplc_analyze_symbol
    • First observedplc_assign_program
    • First observedplc_begin_transaction
    • First observedplc_bind_io
    • First observedplc_commit_changes
    • First observedplc_compare_files
    • First observedplc_compare_projects
    • First observedplc_create_pou
    • First observedplc_create_variable
    • First observedplc_delete_data_type
    • First observedplc_delete_pou
    • First observedplc_delete_variable
    • First observedplc_export_project
    • First observedplc_find_references
    • First observedplc_generate_iec_xml
    • First observedplc_get_capabilities
    • First observedplc_get_project_info
    • First observedplc_ide_close_active
    • First observedplc_ide_export_active
    • First observedplc_ide_list_projects
    • First observedplc_ide_open_copy
    • First observedplc_ide_open_existing
    • First observedplc_ide_probe
    • First observedplc_ide_rebuild_active
    • First observedplc_ide_runtime_status
    • First observedplc_inspect_file
    • First observedplc_list_data_types
    • First observedplc_list_hardware
    • First observedplc_list_io
    • First observedplc_list_ports
    • First observedplc_list_pous
    • First observedplc_list_tasks
    • First observedplc_list_variables
    • First observedplc_open_project
    • First observedplc_plan_rename
    • First observedplc_plan_rename_data_type
    • First observedplc_preview_changes
    • First observedplc_preview_iec_xml_import
    • First observedplc_read_pou
    • First observedplc_read_section
    • First observedplc_register_external
    • First observedplc_rename_data_type
    • First observedplc_rename_variable
    • First observedplc_rollback
    • First observedplc_stage_iec_xml_import
    • First observedplc_unassign_program
    • First observedplc_unbind_io
    • First observedplc_update_ld
    • First observedplc_update_st
    • First observedplc_update_variable
    • First observedplc_validate

TDQS

B3.4/5.0

Scored across 51 tools

Disambiguation4/5

The toolset is large but carefully partitioned: plc_ide_* tools cover live Sysmac IDE automation, while the remaining tools cover offline SMC2 project editing and transactions. Overlaps such as open_project vs. ide_open_existing/ide_open_copy and export_project vs. ide_export_active are explicitly differentiated, though the number of near-neighbor tools raises some misselection risk.

Naming Consistency5/5

All tools use snake_case with a consistent plc_ prefix and verb_noun structure. The ide, transaction, import, and rename families are predictable, and minor variants like get_project_info or analyze_symbol do not break the convention.

Tool Count2/5

At 51 tools, the surface is far beyond the practical 3-15 range and is likely to overwhelm an agent during tool selection. The operations are well-organized and largely non-redundant, which keeps it from being chaotic, but the count is still excessive.

Completeness4/5

Coverage is strong: project open/export, transaction staging/commit/rollback, POU and variable CRUD, references, validation, IEC XML import/export, and IDE open/close/rebuild/runtime status are all present. Minor gaps remain around direct create/update DataType operations and task lifecycle beyond assign/unassign.

Maintenance

ActivityMaintained
ResponsivenessNo recent community issues

Related MCP Connectors

Related MCP Servers

  • F
    license
    A
    quality
    B
    maintenance
    Provides read-only analysis of Mitsubishi GX Works3 PLC projects via MCP, enabling device tracing, cross-referencing, ladder inspection, linting, and report generation without modifying source projects.
    15
    62 PyPI
    10
    -
  • A
    license
    Not graded
    quality
    B
    maintenance
    Exposes read-only tools for OPC UA PLC tag monitoring and diagnostics, and enables template-driven, validated IEC 61131-3 SCL code generation with a mandatory human review gate before download.
    1
    MIT
  • A
    license
    Not graded
    quality
    C
    maintenance
    Enables driving any installed CODESYS 3.5 version (SP18–SP22) from a single MCP server, automatically selecting the right install from each project file's saved version. Exposes 127 tools covering project and POU authoring, compile, online/runtime control, devices and tasks, symbol configuration, multi-device projects, and a version plus git release pipeline.
    4
    MIT
  • A
    license
    Not graded
    quality
    C
    maintenance
    Exposes Rockwell Automation's Logix Designer SDK as 39 tools for programmatic ControlLogix/CompactLogix engineering, letting users create and build Studio 5000 projects, generate and validate L5X from point lists, read/write tags, resolve comm paths and safely go online or download, publish or simulate telemetry over MQTT/OPC UA/EtherNet-IP, and run FAT/SAT acceptance suites. Controller-changing operations are confirm-gated, returning a dry-run plan unless explicitly confirmed.
    MIT