      Enables AI agents to run deterministic data-center engineering calculations and commissioning audits, including liquid-cooling hydraulics, pipe friction and flow checks, corrosion severity classification, protocol search, and defect-code lookup.
      6
      2
      MIT
    • A
      license
      A
      quality
      D
      maintenance
      Provides professional-grade data center engineering calculations including cooling, power, GPU thermal optimization, UPS/battery sizing, tier classification, and commissioning workflows, compliant with ASHRAE and Uptime Institute standards.
      8
      49 npm
      1
      MIT
    • A
      license
      C
      quality
      D
      maintenance
      27 deterministic engineering compliance and calculation tools for the built environment (data-centre PUE and EED, EPBD, NIS2, Eurocode, UAE compliance), callable by AI agents via MCP and REST API. Free tier; every result cites the governing standard.
      27
      MIT
    • A
      license
      A
      quality
      C
      maintenance
      Deterministic AI data-center design tools for sizing, validation, and conceptual rack/site layouts. Supports NVIDIA Hopper, Blackwell, and Rubin profiles. Calculations require a registered AIDC API key; results preserve warnings, RFIs, and pending validations.
      3
      3
      MIT
    • F
      license
      Not graded
      quality
      C
      maintenance
      Provides deterministic, standards-based calculations for data center critical power infrastructure. Enables site selection, generator sizing, UPS sizing, NFPA 110 compliance, and more via 50+ AI agents and 8 compound chains.
      -
    • A
      license
      Not graded
      quality
      B
      maintenance
      Provides AI agents with physics-based corrosion engineering calculations, from rapid handbook lookups to mechanistic electrochemical models with dual-tier pitting assessment for material compatibility screening and corrosion rate prediction.
      1
      MIT

    TDQS

    A4/5.0

    Scored across 3 tools

    Disambiguation5/5

    The three tools address completely different artifacts: a hydraulic sizing calculation, procedure classification (SOP/MOP/EOP), and corrosion coupon classification per ANSI/ISA-71.04. There is no plausible overlap in intent, so an agent cannot reasonably misselect among them.

    Naming Consistency4/5

    All names use consistent snake_case and are descriptive, but the convention is mixed: classify_procedure and classify_corrosion_coupon follow a verb_noun pattern while liquid_loop_hydraulics is a bare noun phrase. The deviation is minor and the topic words still disambiguate clearly.

    Tool Count4/5

    Three tools is on the thin side, but each is a substantive, self-contained engineering calculation with real internal logic (pressure drop, R30 normalisation, procedure gap analysis) rather than a thin wrapper. Nothing feels padded or redundant.

    Completeness4/5

    Each tool fully closes its own loop (inputs, computation, classification output, and caveats like velocity flags and bl-than-G1 warnings), so no dead ends within a task. As a broader data-center facilities surface it is narrow — no airflow/power/electrical or unit-conversion helpers, and no way to carry coupon results across time — but those are scope choices, not broken workflows.