Data Center Auditor MCP Server

Data Center Auditor MCP Server

Data Center Auditor MCP Server

Website License: MIT MCP Standard: ASHRAE TC 9.9 Standard: ANSI/ISA-71.04

A deterministic Model Context Protocol (MCP) server for mission-critical AI data centers, high-density direct-to-chip liquid cooling (NVIDIA GB200 NVL72), and Level 1–5 commissioning TDD protocols.

Powered by the first-principles engineering protocols from Data Center Field Guides by Tristan Howard.


⚠️ Engineering Safety & Liability Disclaimer

IMPORTANT: The calculation formulas, defect code lookups, and commissioning audit tools provided in this server are for first-principles theoretical modeling, educational reference, and design review assistance only.

Fluid hydraulic dynamics, electrical switching (NFPA 70E), and hydrostatic pressure envelopes (ASME B31.3) in mission-critical hyperscale facilities carry severe life-safety, arc-flash, and equipment-damage risks. Output from this tool does not substitute for stamped submittals and peer-reviewed design calculations produced by a licensed Professional Engineer (PE) or manufacturer-certified equipment specifications.


Related MCP server: Corrosion Engineering MCP Server

🛠 Features & Available Tools

This MCP server equips AI agents with 6 deterministic engineering calculation and validation tools:

Tool

Category

Description

Governing Standard

verify_hydraulic_boundary

Thermal / Fluid

Calculates required liquid coolant flow rate ($L/min$, $GPM$), mass balance, heat removal capacity, and ASHRAE liquid cooling class ($W1$–$W4$) for 132 kW NVL72 racks.

ASHRAE TC 9.9 / NVIDIA GB200 NVL72

calculate_pipe_friction_loss

Fluid Hydraulics

Calculates Darcy-Weisbach pressure drop ($\Delta P$), pipe fluid velocity, Reynolds number ($Re$), and erosion risk thresholds ($<0.5\text{ m/s}$ settling, $>2.0\text{ m/s}$ erosion) across DN25–DN100 pipes.

Darcy-Weisbach / Swamee-Jain / ASME B31.3

audit_commissioning_script

TDD Commissioning

Audits MOP, SOP, EOP, and IST Level 1–5 commissioning scripts against physical boundaries, Point of No Return (PONR) rules, and safety gates.

ASHRAE Guideline 0 / NFPA 70E / Uptime

classify_corrosion_severity

Environmental

Classifies whitespace atmospheric corrosion severity for Copper and Silver reactivity rates according to ANSI/ISA-71.04-2013 ($G1$, $G2$, $G3$, $GX$).

ANSI/ISA-71.04-2013 / RoHS

search_field_protocols

Standard Index

Structured lookup for physical boundary formulas, fatal flaw criteria, and engineering thresholds across the 69 Data Center Field Guide protocols.

DCFG Field Handbook

lookup_defect_code

Audit Codes

Fast lookup for fatal commissioning flaws and defect codes (e.g. A-01, A-04, B-02, B-05).

DCFG Defect Taxonomy


🚀 Quick Start & Installation

Option 1: Manual Configuration for Claude Desktop

Add the following to your claude_desktop_config.json (on macOS: ~/Library/Application Support/Claude/claude_desktop_config.json):

{
  "mcpServers": {
    "datacenter-auditor": {
      "command": "node",
      "args": ["/PATH/TO/datacenter-mcp/index.js"]
    }
  }
}

Option 2: Manual Configuration for Cursor

Create or edit .cursor/mcp.json in your project root:

{
  "mcpServers": {
    "datacenter-auditor": {
      "command": "node",
      "args": ["/PATH/TO/datacenter-mcp/index.js"]
    }
  }
}

📐 Governing Physics & Mathematical Formulations

1. Thermal Heat Balance

$$\dot{Q} = \dot{m} \cdot c_p \cdot \Delta T$$ Where $\dot{Q}$ is rack heat dissipation ($132\text{ kW}$ for NVL72), $\dot{m}$ is coolant mass flow, $c_p$ is fluid specific heat ($3.96\text{ kJ/kg}\cdot\text{K}$ for PG25), and $\Delta T$ is cold plate temperature delta ($10\text{ K}$–$15\text{ K}$).

2. Darcy-Weisbach Pressure Drop

$$\Delta P = f \cdot \frac{L}{D} \cdot \frac{\rho v^2}{2}$$ Friction factor $f$ calculated via the Swamee-Jain explicit approximation of the Colebrook-White equation for turbulent pipe flow ($Re \ge 2,300$): $$f = \frac{0.25}{\left[\log_{10}\left(\frac{\varepsilon}{3.7D} + \frac{5.74}{Re^{0.9}}\right)\right]^2}$$

3. Atmospheric Reactivity Monitoring

Evaluation according to ANSI/ISA-71.04-2013 Table 1 for 30-day passive coupon exposure:

  • Level G1 (Mild): $\text{Cu} < 300\text{ \AA/30d}$, $\text{Ag} < 200\text{ \AA/30d}$ (Mandatory for RoHS compliance).

  • Level G2 (Moderate): $\text{Cu} < 1000\text{ \AA/30d}$, $\text{Ag} < 1000\text{ \AA/30d}$.

  • Level G3 (Harsh): $\text{Cu} < 2000\text{ \AA/30d}$, $\text{Ag} < 2000\text{ \AA/30d}$.

  • Level GX (Severe): $\text{Cu} \ge 2000\text{ \AA/30d}$, $\text{Ag} \ge 2000\text{ \AA/30d}$.


📚 References & Comprehensive Specifications

The complete 74-protocol engineering library, case studies, and 9-Volume field guide series are available at:

📄 License

MIT © Tristan Howard (Data Center Field Guides)

Available Tools

6 tools
audit_commissioning_scriptC

Audits a data center commissioning script (MOP, SOP, EOP, or IST Level 1-5) against deterministic physical boundary rules and safety gates.

Inputs: script_text (required), commissioning_level.

calculate_pipe_friction_lossA

Calculates Darcy-Weisbach pipe friction pressure drop, flow velocity, Reynolds number, and erosion thresholds for data center liquid cooling loops.

Inputs: pipe_dn (required), flow_lpm (required), pipe_length_m (required), coolant_type.

classify_corrosion_severityA

Classifies data center whitespace atmospheric corrosion severity according to ANSI/ISA-71.04-2013 for Copper and Silver reactivity.

Inputs: copper_angstroms_30d (required), silver_angstroms_30d (required).

lookup_defect_codeA

Looks up fatal commissioning flaws and defect codes (e.g. A-01, B-02, C-03) from the Data Center Field Guides audit standard.

Inputs: defect_code (required).

search_field_protocolsA

Searches the Data Center Field Guides ground-truth corpus for commissioning procedures, fatal flaw criteria, and engineering formulas.

Inputs: query (required).

verify_hydraulic_boundaryB

Calculates required coolant flow rate, mass balance, heat removal capacity, and ASHRAE Liquid Cooling Class compliance for AI compute racks (e.g., NVIDIA GB200 NVL72).

Inputs: delta_t_c (required), heat_load_kw (required), coolant_type, supply_temp_c, +1 more.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    A3.7/5.0

    Scored across 6 tools

    Disambiguation4/5

    Most tools target clearly distinct actions and artifacts, such as auditing a script, searching field protocols, classifying corrosion, or looking up a defect code. The only potential overlap is between verify_hydraulic_boundary and calculate_pipe_friction_loss, since both perform hydraulic calculations, though their descriptions distinguish system-level rack verification from pipe-level friction loss.

    Naming Consistency5/5

    All six tool names follow a consistent snake_case verb_noun pattern: audit_, verify_, calculate_, search_, classify_, and lookup_. The verbs are specific and the naming convention is predictable throughout.

    Tool Count5/5

    Six tools is well-scoped for a focused data center auditing server. Each tool maps to a distinct audit or engineering sub-task, and there is no evident padding or redundancy.

    Completeness4/5

    The surface covers the core auditing workflow: script audit, hydraulic verification, friction calculations, protocol search, corrosion classification, and defect lookup. Minor gaps exist around report generation/export or batch auditing, but the main lifecycle needs are represented.

    Maintenance

    ActivityMaintained
    ResponsivenessNo recent community issues

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      A
      quality
      D
      maintenance
      Enables AI agents to perform unit-aware engineering calculations with automatic unit conversion, dependency resolution, and access to 500+ units across 75+ categories through the CalcsLive calculation engine.
      3
      14 npm
      MIT
    • A
      license
      Not graded
      quality
      B
      maintenance
      Provides AI agents with physics-based corrosion engineering calculations, from rapid handbook lookups to mechanistic electrochemical models with dual-tier pitting assessment for material compatibility screening and corrosion rate prediction.
      1
      MIT
    • A
      license
      A
      quality
      D
      maintenance
      Provides professional-grade data center engineering calculations including cooling, power, GPU thermal optimization, UPS/battery sizing, tier classification, and commissioning workflows, compliant with ASHRAE and Uptime Institute standards.
      8
      161 npm
      1
      MIT
    • F
      license
      Not graded
      quality
      C
      maintenance
      Provides deterministic, standards-based calculations for data center critical power infrastructure. Enables site selection, generator sizing, UPS sizing, NFPA 110 compliance, and more via 50+ AI agents and 8 compound chains.
      -