Skip to main content
Glama

CI

WARNING

Unofficial software. This is an independent project. It is not affiliated with, endorsed, sponsored or supported by Qoitech AB. Qoitech and Otii are names of Qoitech AB, used here only to identify the hardware this software works with. For official software and support, contact Qoitech.

Use at your own risk. This software switches electrical power to connected equipment. It is provided "as is", without warranty of any kind, express or implied (see sections 7 and 8 of the Apache License 2.0). You are solely responsible for its use and for any damage or loss that results, including damage to the instrument, to devices under test or to other equipment, loss of data, or injury. Check its behaviour with your own setup before relying on it.

otii-ace-mcp

Python driver, interactive CLI and MCP server for the Qoitech Otii Ace Pro power analyzer. It talks to the device directly over USB and turns it into a building block for automation: scripts, CI pipelines, lab test benches, and AI agents that debug hardware on their own.

Tested device: Otii Ace Pro (hardware rev 2, firmware 3.2.5). The driver identifies the device on connection and refuses to operate any other device type, protocol or firmware version.

Power-up of a Zynq-7000 board with its serial console

The power-up of a Zynq-7000 board at 5 V with a 2 A current limit, recorded in the interactive shell (serial numbers and paths masked):

The interactive session that recorded it

The bottom panel lines the board's console up with its power on one time axis, so each boot stage can be read off against the current it draws. The boot loader reports at 0.647 s that it loaded the 4.9 MB kernel image in 393 ms: the plateau of about 1.65 W before it is that load. The kernel's own init at 0.14 s, arriving at 0.917 s, puts the kernel start at about 0.78 s, where the power rises and turns busy; the shell prompt at 0.947 s shows the console up. From about 1.52 s the board settles at around 1.45 W. The faint orange steps behind the text show how many characters per second arrived (right axis).

The board's USB serial adapter is powered by the board itself, so /dev/ttyUSB0 does not exist until the output is switched on, and it disappears again when it goes off. otii-usb therefore looks for the port every 5 ms during the recording and opens it the moment it appears, here 475 ms after the switch-on (the shaded part of the panel); after a disconnect it waits for the port to come back. It joins while the board is already printing: whatever was sent before is lost, and the first printable character after the port opened starts a line. Arrival times are measured on the host and placed on the Otii's time axis to about a millisecond.

Why

Automation. Everything the tool does is a Python call or a one-line command with JSON output: power the device under test, measure voltage, current and power at 50 kS/s, record to CSV and plots, power-cycle. No GUI in the loop, so the same steps run on a desk, in CI and on a test rack.

Automated debugging over MCP. The MCP server gives an agent hands and eyes on the hardware. It can flash new firmware, power-cycle the board, record the boot current and read the numbers back, then compare against the last build: a sleep current that went from 3 µA to 300 µA, a brown-out at start-up, a radio that never powers down. The agent closes the loop itself (change → power → measure → reason → change) and leaves CSV files and plots behind for you to check. Safety is built in: outputs are off and limits are set (5 V, 500 mA) whenever the server starts or stops, and tools that switch power are marked so the client asks first.

Easy to extend in Python. The layers are small and typed. A new device setting is one PropertySpec line; a new analysis is a SampleSink that receives numpy arrays; a new command appears in the CLI, the interactive shell and its completion from one entry in the command catalogue. The built-in simulator lets you develop and test all of it without hardware.

Related MCP server: lab-mcp

Quickstart

First-time setup

git clone https://github.com/bitqan-ae/otii-ace-mcp.git
cd otii-ace-mcp
python3 -m venv .venv                 # create the virtual environment (once)
source .venv/bin/activate             # load it
pip install -r requirements.txt       # dependencies + this package (editable)
otii-usb --simulate status            # works without hardware

Plug in the Otii Ace Pro over USB; it shows up as /dev/ttyACM* (lsusb: 0fce:d1e6). If the port is not accessible, add yourself to the dialout group and log in again.

Every new terminal

cd otii-ace-mcp
source .venv/bin/activate             # load the venv; `deactivate` leaves it
otii-usb status

Without activating, call the tools directly: .venv/bin/otii-usb, .venv/bin/otii-usb-mcp.

Command line

otii-usb status                          # identity, output state, setpoint, current limit
otii-usb measure -t 2                    # 2 s average/min/max of voltage, current, power
otii-usb record -t 60                    # 60 s to otii-<timestamp>.csv and .png
otii-usb record -t 10 --csv run.csv      # CSV only (1000 averaged rows per second)
otii-usb record -t 5 --png boot.png      # plot only
otii-usb record --png --title "Sensor board, boot"   # own plot title (default: model and S/N)
otii-usb record --png --footer "ACME lab"   # own note at the bottom right; --no-footer for none
otii-usb record -t 2 --csv fast.csv --raw   # every sample (50 kHz)
otii-usb record -t 1 --power-on          # output on 50 ms into the recording: the power-up
otii-usb record -t 5 --power-on --png boot.png --serial /dev/ttyUSB0   # with the boot log
otii-usb output on | off                 # switch the main output
otii-usb power-cycle -o 2                # off for 2 s, then on
otii-usb safe                            # all outputs off, 5 V setpoint, 500 mA limit
otii-usb --json measure                  # machine-readable output
otii-usb record --help                   # options and examples for any command

Ctrl-C (or SIGTERM/SIGHUP) stops the running command, switches all outputs off and restores the 5 V / 500 mA defaults. Timed operations show a progress bar on the terminal.

record --power-on captures the first milliseconds after powering the device under test. The main output must be off; it is switched on --pre seconds (default 0.05) into the recording and off again at the end, also on errors. The time the switch-on command was sent (the end of the last data packet received before it) is reported as command_sent_s, drawn as a dashed line in the plot, and marked in the CSV by an extra column output_on (0 before, 1 from the row that contains it). The output then ramps up a few milliseconds later; the recording shows it.

record --serial PORT (with --baud RATE, default 115200, 8N1) reads the serial console of the device under test during the recording and adds a fourth panel below the voltage, labelled with the port; the example at the top shows one, and how a port that appears only with the power is found. Each line is marked by a faint vertical line at the arrival of its first printable character, with the arrival time (bold green) and the received text (black) written upwards behind the marker. Behind the text, a faint orange distribution shows the printable characters per second (right axis, topped by the busiest of 250 bins over the recording). Labels never overlap: a line close to the previous marker gets no marker of its own but follows that marker's label in the next column, with its own arrival time, as long as it ends before the next marker; lines that do not fit are left out, and the note at the bottom left says how many lines are shown. The port is only read, never written. The result reports the line count and when the port was open.

Interactive mode

otii-usb -i                  # or: otii-usb --simulate -i to try it without hardware

The shell starts with a banner, puts the device into the safe state and shows the main output state in the prompt. Tab completes commands, options and file names; ↑ and Ctrl-R search the history (kept in ~/.local/state/otii-usb/history); grey text suggests from history.

Example session (values depend on your device under test):

  ___   _____  ___  ___        _      ____  _____
 / _ \ |_   _||_ _||_ _|      / \    / ___|| ____|
| | | |  | |   | |  | |      / _ \  | |    |  _|
| |_| |  | |   | |  | |     / ___ \ | |___ | |___
 \___/   |_|  |___||___|   /_/   \_\ \____||_____|
  Otii Ace Pro  ·  USB control & measurement  ·  otii-usb 0.1.0

Otii Ace Pro  S/N <serial> · board <board serial> · fw 3.2.5 · protocol 3 · /dev/ttyACM0
✔ safe state: outputs OFF, 5 V setpoint, 500 mA limit

otii Ace Pro ○ OFF ❯ output on
✔ main output OFF -> ON
otii Ace Pro ● ON ❯ measure -t 2
✔ main output ON, 2 s window
channel          avg          min          max          std    samples
mv         5.0000 V     4.9986 V     5.0031 V   452.1 µV    100,050
mc        12.3184 mA   11.9620 mA   12.7741 mA   97.4 µA    100,050
mp        61.5922 mW   59.8094 mW   63.8817 mW  487.2 µW    100,050
otii Ace Pro ● ON ❯ record -t 30 --csv boot.csv --png boot.png
| recording ━━━━━━━━━━━━━━━━━━╸━━━━━━━━━━━━━━━━━━  52% 0:00:15 eta 0:00:14
✔ recorded 30 s
  csv  ~/boot.csv  (30001 rows, 1000 rows/s)
  png  ~/boot.png
otii Ace Pro ● ON ❯ power-cycle -o 2
✔ main output ON -> OFF for 2 s -> ON
otii Ace Pro ● ON ❯ help record
otii Ace Pro ● ON ❯ exit
switching outputs off ...
✔ outputs OFF, defaults restored. bye.

More examples at the prompt:

help                                   list all commands with an example each
help power-cycle                       options and examples for one command
status                                 device identity and state
measure -t 0.1                         quick 100 ms reading
record                                 10 s, CSV and PNG with timestamped names
record -t 60 --csv --png               both outputs, timestamped names
record --csv slow.csv --rate 10        10 averaged rows per second
record --png a.png --title "Board A"   plot titled "Board A"; each record takes its own title
safe --voltage 3.3 --current-limit 0.1 outputs off, then 3.3 V and 100 mA
clear                                  clear the screen

Ctrl-C at the prompt clears the line; during a command it stops the command and switches the outputs off. exit, quit or Ctrl-D leave the shell with the outputs off.

While the shell is idle it polls the device once per second (--poll SECONDS, 0 = off) and warns in bold red when the current reaches the current limit or the device switches the output off by itself, and in yellow above 90 % of the limit:

⚠ 14:02:17  OVERCURRENT: peak 500.0000 mA reached the current limit 500.0000 mA (polled)
⚠ 14:02:18  main output was switched OFF by the device, not by otii-usb (current limit or protection tripped?)

MCP server

otii-usb-mcp                          # stdio server for the attached Otii
otii-usb-mcp --simulate               # same, against the simulator
otii-usb-mcp --voltage 3.3 --current-limit 0.1 --output-dir ~/otii-records

Register it with Claude Code (from the repository, with the venv set up):

claude mcp add otii -- "$PWD/.venv/bin/otii-usb-mcp"

or use the .mcp.json in this repository, which starts .venv/bin/otii-usb-mcp when Claude Code is opened in this directory. Other MCP clients start the same command over stdio.

Tool

What it does

status

model, serial number, firmware, output state, voltage setpoint, current limit

measure(duration_s)

avg/min/max/std of voltage, current and power (≤ 10 s)

record(duration_s, csv, png, rate_hz, name, power_on, pre_trigger_s, title, footer, serial_port, baud)

CSV and/or PNG plot in the output directory (≤ 600 s); title replaces the plot's default title, footer its project note ("" for none); power_on switches the output on inside the recording and off at the end (marked destructive); serial_port (under /dev/) adds the serial console panel

set_output(on)

switch the main output (marked destructive)

power_cycle(off_s)

off, wait, on; always ends on (marked destructive)

At start-up and at shutdown (client disconnect, Ctrl-C, SIGTERM, SIGHUP) the server switches the main and expansion-port outputs off and sets 5 V / 500 mA. A tool that is still running is cancelled first. The server logs the device's identity at start-up and polls it for overcurrent while idle; warnings are added to the next tool result as warnings.

Python API

from otii_usb import ChannelId, OtiiDevice

with OtiiDevice.open() as otii:               # auto-detects the device, checks it is supported
    print(otii.model, otii.info().serial_number)
    otii.apply_safe_defaults()                # outputs off, 5 V, 500 mA
    otii.set_output(True)
    summary = otii.measure(1.0)
    print(summary.current.mean, summary.power.maximum)

    recording = otii.record(2.0)              # numpy float64 arrays per channel
    current = recording[ChannelId.MC]         # amperes, 50 kS/s

    otii.capture(10.0, csv="run.csv", png="run.png")
    otii.set_output(False)

Extending it, for example with a new device setting:

from otii_usb import OtiiDevice
from otii_usb.device import PropertySpec, ScaledIntCodec
from otii_usb.protocol import PropertyId

EXPANSION_VOLTAGE = PropertySpec("expvolt", PropertyId.EXPANSION_VOLTAGE, ScaledIntCodec(1e-6),
                                 unit="V")
with OtiiDevice.open() as otii:
    print(otii.get(EXPANSION_VOLTAGE))        # read-only unless writable=True

or with a live analysis that receives every packet as numpy arrays:

from otii_usb import ChannelId, OtiiDevice
from otii_usb.measurement import SampleSink

class PeakCurrent(SampleSink):
    def __init__(self):
        self.peak = 0.0

    def write(self, sequence, samples):           # one call per 1 ms packet
        if ChannelId.MC in samples:
            self.peak = max(self.peak, float(samples[ChannelId.MC].max()))

with OtiiDevice.open() as otii:
    sink = PeakCurrent()
    otii.stream(sink, 5.0)
    print(f"peak current {sink.peak * 1e3:.3f} mA")

Safety

  • Only the tested device (Otii Ace Pro, firmware 3.2.5) is operated; identification only reads.

  • Safe state (main and expansion outputs off, 5 V, 500 mA) when the MCP server or interactive shell starts, and on every exit; Ctrl-C/SIGTERM/SIGHUP switch the outputs off within milliseconds, also while a long recording runs.

  • Only explicitly writable settings can be changed, and every change is read back.

  • Overcurrent protection is done by the Otii itself: when the main output current reaches the current limit, the device acts on its own (limiting or switching off, according to its current-limit mode). otii-usb sets the limit (500 mA by default) and reports when it is reached or when the device switched the output off; it does not switch it off itself.

The numbered safety and design requirements and the architecture are in docs/contributor/design.md; the protocol is explained in docs/contributor/protocol.md.

Development

source .venv/bin/activate
python -m pytest                      # runs entirely against the simulator
otii-usb --debug --simulate measure   # protocol traffic as hex

CI runs the tests on Python 3.12, 3.13 and 3.14. Agent and contributor guidance is in AGENTS.md.

License

Copyright (c) 2026 Milosch Meriac, developed at Bitqan Systems Design (bitqan.ae). Licensed under the Apache License 2.0.

This project was developed with the help of Anthropic's Claude Code.

Available Tools

5 tools
measureA
Read-onlyIdempotent

Record main voltage [V], current [A] and power [W] for duration_s seconds (0.01..10 s) and return avg/min/max/std per channel plus the output state.

Inputs: duration_s.

power_cycleA
Destructive

Main output off, wait off_s seconds (0.05..60), on. Always ends with the output ON.

Inputs: off_s.

recordA
Destructive

Record main voltage [V], current [A] and power [W] for duration_s seconds (0.01..600) into the server's output directory: a CSV file (columns time_s, voltage_v, current_a, power_w; rate_hz rows per second averaged, 1..50000, null = every sample) and/or a PNG plot over time titled with the Otii model and serial number, or with title (plain text, at most 200 characters), with a grey project note at the bottom right: footer replaces it (same limits), footer="" leaves it out. Select csv and png individually or together (at least one). name: plain file name without suffix (default: timestamped). Returns the absolute paths and avg/min/max/std per channel. power_on=true powers the device under test: the main output must be off; it is switched on pre_trigger_s seconds (0..10, less than duration_s) into the recording and off at the end. The time the switch-on command was sent is marked in the plot and in the CSV column output_on; power_on.command_sent_s in the result. serial_port (a /dev/ path) reads the serial console of the device under test at baud (8N1, nothing is sent) and adds a fourth plot panel with each line at its arrival; needs png.

Inputs: csv, png, baud, name, +7 more.

set_outputA
DestructiveIdempotent

Switch the main power output on or off (powers/unpowers the device under test).

Inputs: on (required).

statusB
Read-onlyIdempotent

Device model, serial numbers, firmware, protocol version, main output state, voltage setpoint and current limit.

Inputs: no named parameters.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    A3.6/5.0

    Scored across 5 tools

    Disambiguation4/5

    The five tools mostly have distinct roles: status reports device state, set_output toggles power, power_cycle performs a timed off/on cycle, and measure/record differ by returning live statistics versus saving files. The main overlap is between measure and record, since both sample voltage/current/power over a duration, but the descriptions make the file-saving and longer-recording distinction reasonably clear.

    Naming Consistency3/5

    The naming is mixed: power_cycle and set_output use verb_noun snake_case, measure and record are bare verbs, and status is a bare noun. It remains readable and domain-appropriate, but there is no single predictable pattern across the set.

    Tool Count5/5

    Five tools is well-scoped for a USB power analyzer/control server. Each tool corresponds to a core operation: status, measurement, recording, output control, and power cycling.

    Completeness3/5

    The surface covers device status, measurement, recording, and output on/off/cycling, but it cannot set the main output voltage or current limit even though status reports those values. For a programmable power supply/analyzer, the lack of setpoint control is a notable functional gap.

    Maintenance

    ActivityMaintained
    ResponsivenessNo recent community issues

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      Not graded
      quality
      D
      maintenance
      Enables control of the Multicomp Pro MP711134 bench power supply and multimeter over USB serial, allowing an LLM agent to power-cycle boards, measure current profiles during boot, run custom voltage/current profiles, and wait for conditions without polling.
      MIT
    • A
      license
      Not graded
      quality
      B
      maintenance
      Enables AI assistants to automatically discover and control supported laboratory instruments over USB, LAN, and serial connections, including power-supply output, setpoint, and protection management plus multimeter measurements.
      4
      MIT
    • A
      license
      A
      quality
      B
      maintenance
      Enables AI assistants to power and measure devices using a Qoitech Otii Arc or Otii Ace, recording current and optional UART logs. It calculates energy, charge, and current statistics for entire recordings, selected time ranges, or intervals between firmware log messages.
      9
      2
      MIT
    • A
      license
      A
      quality
      B
      maintenance
      Lets AI agents control an AX PP300S buck-boost bench power supply over USB serial, including setting voltage/current/protection limits, switching output, reading measurements, logging, and running timed sequences.
      12
      1
      GPL 3.0