otii-usb-mcp
Click on "Deploy Server".
Wait a few minutes for the server to deploy. Once ready, it will show a "Started" state.
In the chat, type
@followed by the MCP server name and your instructions, e.g., "@otii-usb-mcp Power-cycle the board at 5 V and record the boot current for 3 seconds"
That's it! The server will respond to your query, and you can continue using it as needed.
Here is a step-by-step guide with screenshots.
Unofficial software. This is an independent project. It is not affiliated with, endorsed, sponsored or supported by Qoitech AB. Qoitech and Otii are names of Qoitech AB, used here only to identify the hardware this software works with. For official software and support, contact Qoitech.
Use at your own risk. This software switches electrical power to connected equipment. It is provided "as is", without warranty of any kind, express or implied (see sections 7 and 8 of the Apache License 2.0). You are solely responsible for its use and for any damage or loss that results, including damage to the instrument, to devices under test or to other equipment, loss of data, or injury. Check its behaviour with your own setup before relying on it.
otii-ace-mcp
Python driver, interactive CLI and MCP server for the Qoitech Otii Ace Pro power analyzer. It talks to the device directly over USB and turns it into a building block for automation: scripts, CI pipelines, lab test benches, and AI agents that debug hardware on their own.
Tested device: Otii Ace Pro (hardware rev 2, firmware 3.2.5). The driver identifies the device on connection and refuses to operate any other device type, protocol or firmware version.

The power-up of a Zynq-7000 board at 5 V with a 2 A current limit, recorded in the interactive shell (serial numbers and paths masked):

The bottom panel lines the board's console up with its power on one time axis, so each boot
stage can be read off against the current it draws. The boot loader reports at 0.647 s that it
loaded the 4.9 MB kernel image in 393 ms: the plateau of about 1.65 W before it is that load. The
kernel's own init at 0.14 s, arriving at 0.917 s, puts the kernel start at about 0.78 s, where
the power rises and turns busy; the shell prompt at 0.947 s shows the console up. From about
1.52 s the board settles at around 1.45 W. The faint orange steps behind the text show how many
characters per second arrived (right axis).
The board's USB serial adapter is powered by the board itself, so /dev/ttyUSB0 does not exist
until the output is switched on, and it disappears again when it goes off. otii-usb therefore
looks for the port every 5 ms during the recording and opens it the moment it appears, here
475 ms after the switch-on (the shaded part of the panel); after a disconnect it waits for the
port to come back. It joins while the board is already printing: whatever was sent before is
lost, and the first printable character after the port opened starts a line. Arrival times are
measured on the host and placed on the Otii's time axis to about a millisecond.
Why
Automation. Everything the tool does is a Python call or a one-line command with JSON output: power the device under test, measure voltage, current and power at 50 kS/s, record to CSV and plots, power-cycle. No GUI in the loop, so the same steps run on a desk, in CI and on a test rack.
Automated debugging over MCP. The MCP server gives an agent hands and eyes on the hardware. It can flash new firmware, power-cycle the board, record the boot current and read the numbers back, then compare against the last build: a sleep current that went from 3 µA to 300 µA, a brown-out at start-up, a radio that never powers down. The agent closes the loop itself (change → power → measure → reason → change) and leaves CSV files and plots behind for you to check. Safety is built in: outputs are off and limits are set (5 V, 500 mA) whenever the server starts or stops, and tools that switch power are marked so the client asks first.
Easy to extend in Python. The layers are small and typed. A new device setting is one
PropertySpec line; a new analysis is a SampleSink that receives numpy arrays; a new command
appears in the CLI, the interactive shell and its completion from one entry in the command
catalogue. The built-in simulator lets you develop and test all of it without hardware.
Related MCP server: lab-mcp
Quickstart
First-time setup
git clone https://github.com/bitqan-ae/otii-ace-mcp.git
cd otii-ace-mcp
python3 -m venv .venv # create the virtual environment (once)
source .venv/bin/activate # load it
pip install -r requirements.txt # dependencies + this package (editable)
otii-usb --simulate status # works without hardwarePlug in the Otii Ace Pro over USB; it shows up as /dev/ttyACM* (lsusb: 0fce:d1e6). If the
port is not accessible, add yourself to the dialout group and log in again.
Every new terminal
cd otii-ace-mcp
source .venv/bin/activate # load the venv; `deactivate` leaves it
otii-usb statusWithout activating, call the tools directly: .venv/bin/otii-usb, .venv/bin/otii-usb-mcp.
Command line
otii-usb status # identity, output state, setpoint, current limit
otii-usb measure -t 2 # 2 s average/min/max of voltage, current, power
otii-usb record -t 60 # 60 s to otii-<timestamp>.csv and .png
otii-usb record -t 10 --csv run.csv # CSV only (1000 averaged rows per second)
otii-usb record -t 5 --png boot.png # plot only
otii-usb record --png --title "Sensor board, boot" # own plot title (default: model and S/N)
otii-usb record --png --footer "ACME lab" # own note at the bottom right; --no-footer for none
otii-usb record -t 2 --csv fast.csv --raw # every sample (50 kHz)
otii-usb record -t 1 --power-on # output on 50 ms into the recording: the power-up
otii-usb record -t 5 --power-on --png boot.png --serial /dev/ttyUSB0 # with the boot log
otii-usb output on | off # switch the main output
otii-usb power-cycle -o 2 # off for 2 s, then on
otii-usb safe # all outputs off, 5 V setpoint, 500 mA limit
otii-usb --json measure # machine-readable output
otii-usb record --help # options and examples for any commandCtrl-C (or SIGTERM/SIGHUP) stops the running command, switches all outputs off and restores the 5 V / 500 mA defaults. Timed operations show a progress bar on the terminal.
record --power-on captures the first milliseconds after powering the device under test. The
main output must be off; it is switched on --pre seconds (default 0.05) into the recording and
off again at the end, also on errors. The time the switch-on command was sent (the end of the
last data packet received before it) is reported as command_sent_s, drawn as a dashed line in
the plot, and marked in the CSV by an extra column output_on (0 before, 1 from the row that
contains it). The output then ramps up a few milliseconds later; the recording shows it.
record --serial PORT (with --baud RATE, default 115200, 8N1) reads the serial console of the
device under test during the recording and adds a fourth panel below the voltage, labelled with
the port; the example at the top shows one, and how a port that appears only with the power is
found. Each line is marked by a faint vertical line at the arrival of its first printable
character, with the arrival time (bold green) and the received text (black) written upwards behind
the marker. Behind the text, a faint orange distribution shows the printable characters per second
(right axis, topped by the busiest of 250 bins over the recording). Labels never overlap: a line
close to the previous marker gets no marker of its own but follows that marker's label in the next
column, with its own arrival time, as long as it ends before the next marker; lines that do not
fit are left out, and the note at the bottom left says how many lines are shown. The port is only
read, never written. The result reports the line count and when the port was open.
Interactive mode
otii-usb -i # or: otii-usb --simulate -i to try it without hardwareThe shell starts with a banner, puts the device into the safe state and shows the main output
state in the prompt. Tab completes commands, options and file names; ↑ and Ctrl-R search the
history (kept in ~/.local/state/otii-usb/history); grey text suggests from history.
Example session (values depend on your device under test):
___ _____ ___ ___ _ ____ _____
/ _ \ |_ _||_ _||_ _| / \ / ___|| ____|
| | | | | | | | | | / _ \ | | | _|
| |_| | | | | | | | / ___ \ | |___ | |___
\___/ |_| |___||___| /_/ \_\ \____||_____|
Otii Ace Pro · USB control & measurement · otii-usb 0.1.0
Otii Ace Pro S/N <serial> · board <board serial> · fw 3.2.5 · protocol 3 · /dev/ttyACM0
✔ safe state: outputs OFF, 5 V setpoint, 500 mA limit
otii Ace Pro ○ OFF ❯ output on
✔ main output OFF -> ON
otii Ace Pro ● ON ❯ measure -t 2
✔ main output ON, 2 s window
channel avg min max std samples
mv 5.0000 V 4.9986 V 5.0031 V 452.1 µV 100,050
mc 12.3184 mA 11.9620 mA 12.7741 mA 97.4 µA 100,050
mp 61.5922 mW 59.8094 mW 63.8817 mW 487.2 µW 100,050
otii Ace Pro ● ON ❯ record -t 30 --csv boot.csv --png boot.png
| recording ━━━━━━━━━━━━━━━━━━╸━━━━━━━━━━━━━━━━━━ 52% 0:00:15 eta 0:00:14
✔ recorded 30 s
csv ~/boot.csv (30001 rows, 1000 rows/s)
png ~/boot.png
otii Ace Pro ● ON ❯ power-cycle -o 2
✔ main output ON -> OFF for 2 s -> ON
otii Ace Pro ● ON ❯ help record
otii Ace Pro ● ON ❯ exit
switching outputs off ...
✔ outputs OFF, defaults restored. bye.More examples at the prompt:
help list all commands with an example each
help power-cycle options and examples for one command
status device identity and state
measure -t 0.1 quick 100 ms reading
record 10 s, CSV and PNG with timestamped names
record -t 60 --csv --png both outputs, timestamped names
record --csv slow.csv --rate 10 10 averaged rows per second
record --png a.png --title "Board A" plot titled "Board A"; each record takes its own title
safe --voltage 3.3 --current-limit 0.1 outputs off, then 3.3 V and 100 mA
clear clear the screenCtrl-C at the prompt clears the line; during a command it stops the command and switches the
outputs off. exit, quit or Ctrl-D leave the shell with the outputs off.
While the shell is idle it polls the device once per second (--poll SECONDS, 0 = off) and
warns in bold red when the current reaches the current limit or the device switches the
output off by itself, and in yellow above 90 % of the limit:
⚠ 14:02:17 OVERCURRENT: peak 500.0000 mA reached the current limit 500.0000 mA (polled)
⚠ 14:02:18 main output was switched OFF by the device, not by otii-usb (current limit or protection tripped?)MCP server
otii-usb-mcp # stdio server for the attached Otii
otii-usb-mcp --simulate # same, against the simulator
otii-usb-mcp --voltage 3.3 --current-limit 0.1 --output-dir ~/otii-recordsRegister it with Claude Code (from the repository, with the venv set up):
claude mcp add otii -- "$PWD/.venv/bin/otii-usb-mcp"or use the .mcp.json in this repository, which starts .venv/bin/otii-usb-mcp when Claude Code
is opened in this directory. Other MCP clients start the same command over stdio.
Tool | What it does |
| model, serial number, firmware, output state, voltage setpoint, current limit |
| avg/min/max/std of voltage, current and power (≤ 10 s) |
| CSV and/or PNG plot in the output directory (≤ 600 s); |
| switch the main output (marked destructive) |
| off, wait, on; always ends on (marked destructive) |
At start-up and at shutdown (client disconnect, Ctrl-C, SIGTERM, SIGHUP) the server switches the
main and expansion-port outputs off and sets 5 V / 500 mA. A tool that is still running is
cancelled first. The server logs the device's identity at start-up and polls it for
overcurrent while idle; warnings are added to the next tool result as warnings.
Python API
from otii_usb import ChannelId, OtiiDevice
with OtiiDevice.open() as otii: # auto-detects the device, checks it is supported
print(otii.model, otii.info().serial_number)
otii.apply_safe_defaults() # outputs off, 5 V, 500 mA
otii.set_output(True)
summary = otii.measure(1.0)
print(summary.current.mean, summary.power.maximum)
recording = otii.record(2.0) # numpy float64 arrays per channel
current = recording[ChannelId.MC] # amperes, 50 kS/s
otii.capture(10.0, csv="run.csv", png="run.png")
otii.set_output(False)Extending it, for example with a new device setting:
from otii_usb import OtiiDevice
from otii_usb.device import PropertySpec, ScaledIntCodec
from otii_usb.protocol import PropertyId
EXPANSION_VOLTAGE = PropertySpec("expvolt", PropertyId.EXPANSION_VOLTAGE, ScaledIntCodec(1e-6),
unit="V")
with OtiiDevice.open() as otii:
print(otii.get(EXPANSION_VOLTAGE)) # read-only unless writable=Trueor with a live analysis that receives every packet as numpy arrays:
from otii_usb import ChannelId, OtiiDevice
from otii_usb.measurement import SampleSink
class PeakCurrent(SampleSink):
def __init__(self):
self.peak = 0.0
def write(self, sequence, samples): # one call per 1 ms packet
if ChannelId.MC in samples:
self.peak = max(self.peak, float(samples[ChannelId.MC].max()))
with OtiiDevice.open() as otii:
sink = PeakCurrent()
otii.stream(sink, 5.0)
print(f"peak current {sink.peak * 1e3:.3f} mA")Safety
Only the tested device (Otii Ace Pro, firmware 3.2.5) is operated; identification only reads.
Safe state (main and expansion outputs off, 5 V, 500 mA) when the MCP server or interactive shell starts, and on every exit; Ctrl-C/SIGTERM/SIGHUP switch the outputs off within milliseconds, also while a long recording runs.
Only explicitly writable settings can be changed, and every change is read back.
Overcurrent protection is done by the Otii itself: when the main output current reaches the current limit, the device acts on its own (limiting or switching off, according to its current-limit mode).
otii-usbsets the limit (500 mA by default) and reports when it is reached or when the device switched the output off; it does not switch it off itself.
The numbered safety and design requirements and the architecture are in docs/contributor/design.md; the protocol is explained in docs/contributor/protocol.md.
Development
source .venv/bin/activate
python -m pytest # runs entirely against the simulator
otii-usb --debug --simulate measure # protocol traffic as hexCI runs the tests on Python 3.12, 3.13 and 3.14. Agent and contributor guidance is in AGENTS.md.
License
Copyright (c) 2026 Milosch Meriac, developed at Bitqan Systems Design (bitqan.ae). Licensed under the Apache License 2.0.
This project was developed with the help of Anthropic's Claude Code.
Available Tools
5 toolsmeasureARead-onlyIdempotent
Record main voltage [V], current [A] and power [W] for duration_s seconds (0.01..10 s) and return avg/min/max/std per channel plus the output state.
Inputs: duration_s.
power_cycleADestructive
Main output off, wait off_s seconds (0.05..60), on. Always ends with the output ON.
Inputs: off_s.
recordADestructive
Record main voltage [V], current [A] and power [W] for duration_s seconds (0.01..600) into the server's output directory: a CSV file (columns time_s, voltage_v, current_a, power_w; rate_hz rows per second averaged, 1..50000, null = every sample) and/or a PNG plot over time titled with the Otii model and serial number, or with title (plain text, at most 200 characters), with a grey project note at the bottom right: footer replaces it (same limits), footer="" leaves it out. Select csv and png individually or together (at least one). name: plain file name without suffix (default: timestamped). Returns the absolute paths and avg/min/max/std per channel. power_on=true powers the device under test: the main output must be off; it is switched on pre_trigger_s seconds (0..10, less than duration_s) into the recording and off at the end. The time the switch-on command was sent is marked in the plot and in the CSV column output_on; power_on.command_sent_s in the result. serial_port (a /dev/ path) reads the serial console of the device under test at baud (8N1, nothing is sent) and adds a fourth plot panel with each line at its arrival; needs png.
Inputs: csv, png, baud, name, +7 more.
set_outputADestructiveIdempotent
Switch the main power output on or off (powers/unpowers the device under test).
Inputs: on (required).
statusBRead-onlyIdempotent
Device model, serial numbers, firmware, protocol version, main output state, voltage setpoint and current limit.
Inputs: no named parameters.
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
TDQS
Scored across 5 tools
The five tools mostly have distinct roles: status reports device state, set_output toggles power, power_cycle performs a timed off/on cycle, and measure/record differ by returning live statistics versus saving files. The main overlap is between measure and record, since both sample voltage/current/power over a duration, but the descriptions make the file-saving and longer-recording distinction reasonably clear.
The naming is mixed: power_cycle and set_output use verb_noun snake_case, measure and record are bare verbs, and status is a bare noun. It remains readable and domain-appropriate, but there is no single predictable pattern across the set.
Five tools is well-scoped for a USB power analyzer/control server. Each tool corresponds to a core operation: status, measurement, recording, output control, and power cycling.
The surface covers device status, measurement, recording, and output on/off/cycling, but it cannot set the main output voltage or current limit even though status reports those values. For a programmable power supply/analyzer, the lack of setpoint control is a notable functional gap.
Maintenance
Related MCP Connectors
Protocol-native energy infrastructure orchestration for AI data centers. Provides 46 MCP tools across 8 grid protocols (IEC-61850, DNP3, Modbus, OCPP, OpenADR, IEEE 2030.5, IEC 60870-5-104, ICCP) with 5 core API primitives: connect, dispatch, settle, comply, and intel. Enables AI agents to programmatically interact with substations, grid interfaces, and energy assets for real-time workload-grid coordination.
Design circuits, simulate and verify embedded firmware, and lay out PCBs with AI agents.
Home energy for AI assistants: live Power flow, Energy history, solar forecast, and device control.
Operate Linux, macOS and Windows from your LLM. Every action runs through an auditable allowlist.
Related MCP Servers
- AlicenseNot gradedqualityDmaintenanceEnables control of the Multicomp Pro MP711134 bench power supply and multimeter over USB serial, allowing an LLM agent to power-cycle boards, measure current profiles during boot, run custom voltage/current profiles, and wait for conditions without polling.MIT
- AlicenseNot gradedqualityBmaintenanceEnables AI assistants to automatically discover and control supported laboratory instruments over USB, LAN, and serial connections, including power-supply output, setpoint, and protection management plus multimeter measurements.4MIT

Otii MCP Serverofficial
AlicenseAqualityBmaintenanceEnables AI assistants to power and measure devices using a Qoitech Otii Arc or Otii Ace, recording current and optional UART logs. It calculates energy, charge, and current statistics for entire recordings, selected time ranges, or intervals between firmware log messages.92MIT- AlicenseAqualityBmaintenanceLets AI agents control an AX PP300S buck-boost bench power supply over USB serial, including setting voltage/current/protection limits, switching output, reading measurements, logging, and running timed sequences.121GPL 3.0