otii-usb-mcp
Server Configuration
Describes the environment variables required to run the server.
| Name | Required | Description | Default |
|---|---|---|---|
| --voltage | No | Voltage setpoint applied at server start-up. | |
| --simulate | No | Run the server against the built-in simulator instead of the attached Otii hardware. | |
| --output-dir | No | Directory where recorded CSV files and PNG plots are written. | |
| --current-limit | No | Current limit applied at server start-up. |
Instructions
Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.
Controls a Qoitech Otii Ace Pro power analyzer over USB: read main output voltage/current/power, record them to CSV files and PNG plots, switch the main output, power-cycle the device under test. All values are SI units.
Capabilities
Features and capabilities supported by this server
Protocol revision2025-11-25
| Capability | Details |
|---|---|
| tools | {
"listChanged": false
} |
| prompts | {
"listChanged": false
} |
| resources | {
"subscribe": false,
"listChanged": false
} |
Tools
Functions exposed to the LLM to take actions
| Name | Description |
|---|---|
| statusB | Device model, serial numbers, firmware, protocol version, main output state, voltage setpoint and current limit. |
| measureA | Record main voltage [V], current [A] and power [W] for duration_s seconds (0.01..10 s) and return avg/min/max/std per channel plus the output state. |
| recordA | Record main voltage [V], current [A] and power [W] for duration_s seconds (0.01..600) into the server's output directory: a CSV file (columns time_s, voltage_v, current_a, power_w; rate_hz rows per second averaged, 1..50000, null = every sample) and/or a PNG plot over time titled with the Otii model and serial number, or with title (plain text, at most 200 characters), with a grey project note at the bottom right: footer replaces it (same limits), footer="" leaves it out. Select csv and png individually or together (at least one). name: plain file name without suffix (default: timestamped). Returns the absolute paths and avg/min/max/std per channel. power_on=true powers the device under test: the main output must be off; it is switched on pre_trigger_s seconds (0..10, less than duration_s) into the recording and off at the end. The time the switch-on command was sent is marked in the plot and in the CSV column output_on; power_on.command_sent_s in the result. serial_port (a /dev/ path) reads the serial console of the device under test at baud (8N1, nothing is sent) and adds a fourth plot panel with each line at its arrival; needs png. |
| set_outputA | Switch the main power output on or off (powers/unpowers the device under test). |
| power_cycleA | Main output off, wait off_s seconds (0.05..60), on. Always ends with the output ON. |
Prompts
Interactive templates invoked by user choice
| Name | Description |
|---|---|
No prompts | |
Resources
Contextual data attached and managed by the client
| Name | Description |
|---|---|
No resources | |
TDQS
Scored across 5 tools
The five tools mostly have distinct roles: status reports device state, set_output toggles power, power_cycle performs a timed off/on cycle, and measure/record differ by returning live statistics versus saving files. The main overlap is between measure and record, since both sample voltage/current/power over a duration, but the descriptions make the file-saving and longer-recording distinction reasonably clear.
The naming is mixed: power_cycle and set_output use verb_noun snake_case, measure and record are bare verbs, and status is a bare noun. It remains readable and domain-appropriate, but there is no single predictable pattern across the set.
Five tools is well-scoped for a USB power analyzer/control server. Each tool corresponds to a core operation: status, measurement, recording, output control, and power cycling.
The surface covers device status, measurement, recording, and output on/off/cycling, but it cannot set the main output voltage or current limit even though status reports those values. For a programmable power supply/analyzer, the lack of setpoint control is a notable functional gap.