Skip to main content
Glama

rungkit

English | 日本語

An AI-native toolkit for PLC ladder programs. rungkit keeps a ladder diagram as a series-parallel tree, lets an AI agent edit it over MCP, and lets the agent check its own work on a scan simulator. It supports Mitsubishi (MELSEC iQ-R) and IEC 61131-3, and reads and writes ladder text (.ldt), JSON, the MELSEC instruction list, Structured Text and PLCopen XML.

Status: prototype (0.x). Editing commands, simulator, MCP server, PLCopen XML and a browser version are in place.

rungkit in the browser: ribbon of edit tools on top, ladder text on the left, the diagram with a parts palette on the right, scenario results below

Try it in the browser

The browser version runs entirely in the page (Go compiled to WebAssembly): write .ldt on the left and see the ladder diagram and diagnostics as you type, click an element to jump to its line or edit it on the diagram (drag contacts, coils, timers and counters from the parts palette onto it, or use the ribbon buttons; Delete and Esc work too), run .ldtest scenarios with a trace, and export to every format. Dark and light themes. Nothing is sent anywhere; your input stays in the browser.

Open it at https://piyoone3939.github.io/rungkit/ (updated with each release by .github/workflows/pages.yml), or build it yourself:

sh web/build.sh                          # builds web/dist
python -m http.server -d web/dist 8000   # then open http://localhost:8000

Related MCP server: io.github.purinzan/gx3-cli-mcp

Install

go install github.com/Piyoone3939/rungkit/cmd/rungkit@latest

Or download a binary for Windows, macOS or Linux from GitHub Releases.

Use it from an AI (MCP)

claude mcp add rungkit -- rungkit mcp
  • Listed in the official MCP Registry as io.github.Piyoone3939/rungkit

  • Each release also has MCP Bundles (rungkit-mcp-<os>-<arch>.mcpb) that apps supporting MCPB, such as Claude Desktop, install by opening the file

  • rungkit mcp FILE starts with FILE open

  • The MCP server reads and writes only inside the folder it was started in (change with -root DIR); standard input (-) is refused

Tools:

Tool

What it does

open_program / new_program / save_program

open / start / save (files change only on save)

read_program

show the program with rung IDs (// r1) and element IDs (X0@e3)

edit_program

apply a list of edit commands; all or nothing; one undo step

undo / redo

undo / redo

check_program

errors and warnings with codes, rung and element IDs

run_scenario

run scenarios on the simulator (text or a .ldtest path; trace records every scan)

export_program

write melsec / gxw3 / st / plcopen / json / ldt / ascii / svg

Edit commands (ops of edit_program):

Command

What it does

add_rung(text, after?, comment?, label?)

add a rung

replace_rung(rung, text) / delete_rung(rung) / move_rung(rung, after) / set_rung(rung, comment?, label?)

replace, delete, move or comment a rung

insert_series(target, position, text)

put conditions before or after an element

insert_parallel(target, to?, text)

add a branch parallel to an element (or the series range target..to); on an output it adds an output branch

replace_element(target, text) / delete_element(target) / set_operand(target, operand)

replace, delete or re-address an element

set_symbol(name, type?, address?, comment?) / delete_symbol(name)

device comments and variable declarations

Example: add an emergency stop after the stop button

{"ops": [
  {"op": "insert_series", "target": "e3", "position": "after", "text": "!X3"},
  {"op": "set_symbol", "name": "X3", "comment": "emergency stop"}
]}

Edits that would make a rung an invalid ladder (a contact right of an output, …) are refused with the reason. Device mistakes (writing an input, …) are not refused but returned as diagnostics, so the agent can fix them next.

Ladder text (.ldt)

profile melsec-iqr

sym X0 "start button"
sym X1 "stop button"
sym Y0 "conveyor motor"

rung "run, self-holding" {
  (X0 | Y0) & !X1 -> OUT(Y0)
}

rung "lamp and arrival" {
  Y0 -> {
    OUT(Y1)
    rise(X2) -> SET(M10)
  }
}

Syntax

Meaning

A & B

series (AND); binds tighter than |

A | B

parallel (OR)

!X1

normally closed contact

rise(X0) / fall(X0)

rising / falling edge

[D0 >= K100]

comparison (= <> < <= > >=)

condition -> output

one output at the right end, or a { } block of branches

OUT SET RST PLS PLF

coils

TON(T0, K50) / CTU(C0, K10)

timer / counter

MOV ADD SUB MUL DIV INC DEC (suffix P: once per rising edge)

instructions

// ...

comment

Example: examples/conveyor.ldt

Command line

rungkit check examples/conveyor.ldt          # errors and warnings
rungkit fmt -w examples/conveyor.ldt         # canonical form
rungkit export -to melsec examples/conveyor.ldt
rungkit export -to gxw3 -o conveyor.csv examples/conveyor.ldt   # CSV for GX Works3 (Edit > Import File)
rungkit export -to st examples/conveyor.ldt
rungkit export -to json examples/conveyor.ldt
rungkit export -to ascii examples/conveyor.ldt   # the ladder drawn as text (svg for a picture)

check gives every problem a code (E_READ_ONLY, …) and a line and column, so an agent can fix them one by one.

Messages are available in English and Japanese, chosen by -lang en|ja, then RUNGKIT_LANG, then the system language.

PLCopen XML

Reads and writes PLCopen XML (TC6 v2.01) Ladder Diagram, to exchange programs with Beremiz, OpenPLC Editor, CODESYS and others.

rungkit export -to plcopen -name Conveyor examples/conveyor.ldt > conveyor.xml
rungkit check conveyor.xml          # .xml opens directly (fmt / test / mcp too)
  • Exports validate against the official schema (tc6_xml_v201.xsd) and build as is in Beremiz (procedure and results); a default 10 ms task is included

  • Beremiz runs timer and counter calls after the coils, so a rung reading a timer sees it one scan later than on MELSEC; use the ST export for rung-by-rung semantics

  • OpenPLC Editor v4: its importer was read against rungkit's export (not run yet). Rungs, contacts, coils, timers and instructions match its structure; a rung with a comparison should import with OpenPLC's own layout warning (details)

  • Supported: contacts (NO/NC/rising/falling), coils (set/reset/pulse), TON/TOF/TP/CTU, comparisons (EQ/NE/LT/LE/GT/GE), MOVE/ADD/SUB/MUL/DIV, pulse instructions (through R_TRIG), rung comments

  • Import turns the wiring graph back into a series-parallel tree; chained coils and wired ORs work. Circuits that are not series-parallel (bridges) are refused with E_NON_SERIES_PARALLEL

  • PLCopen is IEC, so melsec programs are written with IEC spellings (K10 → 10, H1F → 16#1F, timer K50 → T#5000ms) and the profile is kept in addData to restore MELSEC spellings on import

  • Changed by a round trip: INC/DEC become ADD/SUB (same behavior), RST of a word becomes MOV(K0, …), independent circuits in one rung become separate rungs

  • Not exportable: RST of timers and counters, MELSEC timers with a word device as preset

Simulator (.ldtest)

Runs the program scan by scan on virtual time and checks it against scenarios.

scan 10ms

test "counts a part 5 s after it arrives" {
  set X0 on
  run 1             // one scan
  set X0 off
  set X2 on
  run 4s            // 4 s of virtual time
  expect T0 off
  wait T0 on within 2s
  expect D0 1
}

Command

Meaning

set OP value

set an input or other device (on off 123 K123 H1F 5s)

force OP value / unforce OP

pin a value (program writes are ignored) / release

run N / run 5s

run N scans / a span of time

expect OP value

check the value now

wait OP value within 6s

run until the value appears; fail after the time

watch OP...

record after every scan

// ... or # ...

comment

T0.ET (timer elapsed time) and C0.CV (counter value) can be read too. Every test starts from a fresh state.

rungkit test examples/conveyor.ldt examples/conveyor.ldtest
rungkit test -trace examples/conveyor.ldt examples/conveyor.ldtest   # table of scans where values changed
rungkit test -json examples/conveyor.ldt examples/conveyor.ldtest    # for agents

The simulator follows ladder semantics:

  • Rungs run top to bottom and every instruction runs every scan (no short-circuit), so edges and timers never miss an input

  • Outputs are written immediately; later rungs in the same scan see them

  • An output branch uses the power flow from before the branch (like MELSEC MPS)

  • MELSEC T adds ticks of a free-running 100 ms clock each time it runs, as the CPU does, so it may turn on up to 100 ms before "preset + 1 scan"; counters stop at the set value (a set value of 0 counts as 1); MUL writes the high word to D(n+1), DIV the remainder to D(n+1), words wrap at 16 bits

  • SM400 (always ON), SM401 (always OFF), SM402 (ON for the first scan)

  • Division by zero stops with an error naming the scan, rung and element

Profiles

Name

melsec-iqr

Mitsubishi iQ-R: X/Y/B/W in hexadecimal, D0.3 bit of word, K/H constants, timers in 100 ms

melsec-fx5

Mitsubishi FX5: like melsec-iqr, but X/Y in octal (X0-X7, X10, …)

iec

IEC 61131-3: declare with sym name : type @ address, %IX0.0, T#5s

Structure (onion architecture)

Dependencies point inward only; internal/architecture_test.go enforces it.

Layer

Package

Role

Domain

ladder

rung tree, normalization, shape rules, IDs

profile

vendor devices and instructions

check

errors and warnings

sim

scan simulator

Application

editing

edit commands, undo and redo

scenario

running scenarios

workspace

open, save, check, edit, export, scenarios (what CLI and MCP call); declares the interfaces it needs

Infrastructure

ldt

.ldt text

ldtest

.ldtest scenarios

jsoncodec

JSON

export/melsec / export/st

MELSEC list / Structured Text

plcopen

PLCopen XML

filestore

files (outside the working folder refused for MCP)

locale

system language

render

ladder drawings as text (ascii) and SVG (svg)

Presentation

cli / mcpserver / web

command line / MCP server / browser bindings

Shared

i18n

English and Japanese messages (used by every layer; standard library only)

Composition

cmd/rungkit / cmd/rungkit-web

wire the adapters and start (CLI and MCP / browser)

Safety

  • rungkit does not talk to real PLCs (no download, monitoring or forcing). Review what it writes and load it with the vendor's tool

  • Check ladder written by an AI with check and scenarios before use. Build safety functions such as emergency stops in wiring and safety devices, not in software

  • The MELSEC instruction sequence follows the standard conversion rules, and the simulator follows Mitsubishi's manuals (results). -to gxw3 writes the CSV GX Works3 imports, following the format in its operating manual, but importing it into GX Works3 has not been tried yet (how to check)

  • Mitsubishi Electric, MELSEC, GX Works and others are trademarks of their owners. rungkit is not affiliated with them

Contributing

See CONTRIBUTING.md. Issues and pull requests are welcome in English or Japanese.

License

Your choice of MIT or Apache-2.0.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      Not graded
      quality
      D
      maintenance
      The first and only MCP server for PLC (Programmable Logic Controller) intelligence. Give any AI agent direct access to industrial automation data — ladder logic, tag databases, cross-references, fault root cause analysis, and sequence blockers
      MIT
    • F
      license
      A
      quality
      C
      maintenance
      Lets AI agents and users analyze Mitsubishi MELSEC .gx3 projects directly, tracing coil conditions, checking device references, comparing program changes, and inspecting ladder logic without opening GX Works3.
      13
      4
      -
    • A
      license
      A
      quality
      B
      maintenance
      Enables lossless parsing, inspection, validation, simulation, and creation or editing of FATEK .ldr ladder-logic files through local stdio MCP tools, including a user-import-verified start/stop template. New files are written to an artifacts directory so existing files and original samples are never overwritten.
      48
      23
      3
      MIT
    • A
      license
      Not graded
      quality
      B
      maintenance
      Enables an AI agent to write ladder logic and import programs and comments into Mitsubishi GX Works2, Siemens TIA Portal and Omron CX-Programmer through a single MCP endpoint that routes vendor-prefixed tools to each tool's own backend. Backends keep their own approval flows while a shared rule withholds live-PLC writes and deletions.