Skip to main content
Glama

multi-plc-agent

One MCP server that lets an AI agent write ladder logic in several PLC engineering tools: Mitsubishi GX Works2, Siemens TIA Portal and Omron CX-Programmer.

multi-plc-agent does not drive any PLC software by itself. It starts one existing MCP server per tool, gives every tool a vendor prefix (mitsubishi_, siemens_, omron_) and exposes them as one server. Each backend keeps its own approval flow and safety checks. The router adds one shared rule on top: tools that act on a live PLC or delete project content are not exposed.

Supported software

Vendor

Software

Backend

How it writes

Verified on

Mitsubishi

GX Works2 1.580 and 1.635

Wayan123/gxworks-agent (fork of Arienax/gxworks-agent)

Drives the GX Works2 UI: CSV import of the program and device comments

1.580.0.1 English UI, FX3U: program and comments imported, export matched

Siemens

TIA Portal V20 / V21

bulaofen0036-coder/TIA_Portal_Openness_MCP v2.7.8

Official TIA Openness API, LAD as S7DCL text

V20, S7-1200 1212C: FC + OB1 + tags imported, compile 0 errors / 0 warnings

Omron

CX-Programmer 9.x, CP1E

BlackUppsss/Cx-Proggrammer-MCP

Edits .cxt/.cxp project files directly

9.75, CP1E-NA: project opened, compile 0 errors / 0 warnings

Mitsubishi

GX Works3

none yet

—

Not supported, see ROADMAP.md

"Verified on" lists only what was actually run. Other CPUs and versions may work, but they have not been tested.

Related MCP server: x402-industrial-mcp

Install (Windows)

Install each backend you need by following its own README, then:

git clone https://github.com/Wayan123/multi-plc-agent.git
cd multi-plc-agent
py -3 -m pip install .
copy config.example.json config.json

The router has no dependencies outside the Python standard library (3.10+).

Edit config.json, or set the variables it refers to:

Variable

Points to

GXWORKS_AGENT_DIR

gxworks-agent checkout with its .venv-mcp

TIA_MCP_DIR

extracted TIA_MCP_Delivery_v* folder

CX_MCP_DIR

Cx-Proggrammer-MCP checkout with its .venv

CX_PROJECT

the .cxt file the Omron backend edits

Set "enabled": false on any backend you don't use. Check that every backend starts:

multi-plc-agent --config config.json --check

The command exits with 0 only when every enabled backend reports running.

Connect an MCP client

{
  "mcpServers": {
    "multi-plc": {
      "command": "multi-plc-agent",
      "args": ["--config", "C:\\path\\to\\config.json"]
    }
  }
}

Ask the agent to call list_plc_backends first. It returns each backend's status, server identity, exposed tool count and the tools that were withheld.

What is not exposed

Backend

Withheld by default

Why

Siemens

DownloadToPlc, GoOnline, SetWatchTableModifyValue, every Delete*, ClearExports, EnsureOpennessUserGroup, Doctor

Live PLC writes, deletions, and a group change that runs through UAC

Siemens

The same names called through CallTool

CallTool reaches tools that aren't listed, so the router checks the inner name

Omron

delete_rung

Deletion

To expose a withheld tool on one backend, add "allow": ["ToolName"] to it. To withhold more tools, use "deny".

Per-backend notes

  • GX Works2. Native compile and live ST/FBD sessions still require 1.635.0.1. On 1.580, only Ladder CSV import and export are enabled. Save the project in GX Works2 yourself, because the tool won't save an unnamed project. The 1.580 support is proposed upstream in Arienax/gxworks-agent#11.

  • TIA Portal. Add your Windows user to the Siemens TIA Openness group yourself and sign in again before the first start. Otherwise the server tries to do it through UAC and exits if that fails. TIA Portal asks for Openness access on every connect unless you choose "Yes to all".

  • CX-Programmer. The backend edits one project file, set by --project. Close the project in CX-Programmer before the agent commits. If it was open, close it without saving and reopen it. The backend was written for CP1E. Its address and instruction checks do not cover CP1L, CP1H, CJ or CS.

Safety

Generated ladder logic is a draft. Review it and test it in a simulator (GX Simulator2, PLCSIM, CX-Simulator) before it reaches equipment. Emergency stop, guarding, two-hand control and overload protection must be implemented by independent safety hardware, not by AI-generated logic.

Development

py -3 -m pip install pytest
py -3 -m pytest tests -q

The tests start fake stdio backends. They need no PLC software.

License

Apache-2.0, see LICENSE. Backends are separate projects under their own licenses, see NOTICE. This repository does not include or redistribute their code.

Related MCP Connectors

Related MCP Servers

  • F
    license
    Not graded
    quality
    B
    maintenance
    MCP server that connects AI assistants to Siemens TIA Portal via the Openness API. AI-assisted PLC programming, project management, hardware configuration, cross-reference analysis, and deployment. 19 tools, 230 actions.
    51
    -
  • A
    license
    Not graded
    quality
    D
    maintenance
    The first and only MCP server for PLC (Programmable Logic Controller) intelligence. Give any AI agent direct access to industrial automation data — ladder logic, tag databases, cross-references, fault root cause analysis, and sequence blockers
    MIT
  • F
    license
    Not graded
    quality
    C
    maintenance
    An MCP bridge for Siemens TIA Portal that enables AI assistants to inspect PLC projects, import/export programs, and compile with read-only defaults and opt-in writes.
    -
  • F
    license
    Not graded
    quality
    B
    maintenance
    Enables AI to operate STEP 7-Micro/WIN SMART via MCP, supporting offline STL/AWL analysis, project inspection, online PLC monitoring (snap7), and engine-injected operations like compile, download, upload, and symbol management through natural language.